Home » Service & Support » Technical Documentation
LNG Regasification Terminals - Cryogenic Control Valve Selection
Release time:2026-11-28 11:55:43 | Views:

Cryogenic control valves in LNG regasification terminals operate under deep-cold conditions, where low-temperature material toughness, packing isolation by an extended bonnet and compensation for seal contraction govern selection. Based on official data for the Fisher easy-e cryogenic family and Neles cryogenic butterfly valves, this article reviews the general selection dimensions of medium, temperature, pressure, material, size, flow characteristic, sealing and explosion protection; specific parameters are subject to the official catalogue, standard texts and design conditions.

I. Service Conditions and Product Positioning

ItemContent
ServiceLNG unloading, regasification, tank pressure control and cryogenic liquid throttling
MediumLNG and cryogenic liquids/gases, prone to vaporization and flashing after throttling
TemperatureDeep-cold; material low-temperature rating and extended bonnet set by design conditions
ConstructionStainless steel body plus extended bonnet keeping packing away from the cold zone
RepresentativeFisher easy-e ET-C / EWT-C / EZ-C; Neles BWX cryogenic butterfly; SAMSON cryogenic valves
Main referencesEmerson product bulletin 51.1:easy-e Cryogenic, D102189X012; Neles BWX manual 2bwx70en

Sources: Emerson product bulletin 51.1:easy-e Cryogenic, D102189X012; Fisher easy-e instruction manual D100390X012; Neles BWX cryogenic butterfly manual 2bwx70en; subject to the official catalogue.

Control valve illustration
Control valve illustration, not the actual model; parameters subject to the official catalogue

II. Temperature and Pressure Boundaries

DimensionSelection directionCheck item
Design temperatureSelect body and extended bonnet by low-temperature material ratingVerify minimum service temperature in the official manual
Pressure classFlange CL150 / CL300 / CL600Check against ASME B16.5 and ASME B16.34
Differential / flashingCryogenic liquid expands after throttlingCheck allowable differential, velocity and downstream pipe size
End connectionFlanged RF / RTJ or weldedConnection per pipe class and design conditions
Flow directionInstall per official manualSome low-noise trims require flow-up

Basis: ASME B16.5 and ASME B16.34; Emerson bulletin D102189X012 (flange classes and cryogenic construction); subject to standard texts and official catalogue.

III. Valve Types and Trim Construction

TypeConstructionApplication
Single-seat globe (ET-C)Cage-guided, balanced plug, push-down-to-closeGeneral cryogenic throttling and on/off; balanced plug lowers actuator thrust
Expanded-end (EWT-C)ET-C with expanded end connectionsWelded joint to cryogenic piping
Unbalanced post-guided (EZ-C)No cage, post-guided, unbalanced plugSmall-bore cryogenic throttling
Cryogenic HP butterfly (BWX)Double-eccentric metal seat, extended stem, cold shock testLarge bore and emergency shutoff

Determine valve type by size, pressure class and function (throttling or shutoff) first, then check trim and extended-bonnet options against the official catalogue.

Sources: Emerson bulletin D102189X012; Fisher easy-e instruction manual D100390X012; Neles BWX manual 2bwx70en.

IV. Materials and Sealing

PartMaterial / constructionNote
Body and bonnetAustenitic stainless CF8M (316)Low-temperature toughness per ASME B16.34 and official catalogue
Seat ringBolted-inCompensates low-temperature contraction, avoids loose threaded seat
Plug sealCryogenic-specific seal ringReplaces standard elastomer to avoid low-temperature embrittlement
SeatMetal-to-metalReliable tight shutoff at ambient and cryogenic temperature
PackingCryogenic-capable packing systemFugitive emission figures per official catalogue
ExtensionWelded / machined extended bonnetKeeps stuffing box away from the cold zone

Sources: Emerson bulletin D102189X012; Neles BWX manual 2bwx70en (CrNi steel and cryogenic extended stem); ASME B16.34.

V. Actuator and Accessories

ItemConfiguration point
ActuatorBalanced plug allows smaller actuator; thrust per official sizing
PositionerSelect by protocol (HART / PROFIBUS PA / FF) and local protection
Explosion protectionEx ia intrinsic safety is NOT Ex d flameproof; certificate per nameplate
Functional safetySome families offer SIL capability, subject to official certification
Oxygen serviceRequires notified-body test report, confirmed per official manual
InsulationExtended bonnet and yoke arranged to allow cold insulation

Sources: Emerson bulletin D102189X012; Neles BWX manual 2bwx70en; approvals subject to official documents and nameplate.

VI. Selection Guide and Common Configurations

StepCheck item
1 MediumCryogenic liquid/gas, oxygen or clean service
2 T & PMinimum service temperature, pressure class, allowable differential
3 TypeGlobe single-seat or butterfly, by size and shutoff duty
4 MaterialStainless body, cryogenic seat seal, packing system
5 ActuatorThrust, protocol, Ex protection, SIL and insulation layout

Selection guide: The sequence is: define service boundaries, then valve type and materials, then actuator and accessories. Determine available materials and construction from design temperature and pressure class, fix valve type and extended bonnet by size and function, then check seat seal, packing, actuator thrust and Ex approval. Parameters are subject to the official catalogue, standard texts and design conditions; no project-specific values are invented.

Common models and configurations: Common configurations: Fisher easy-e ET-C / EWT-C / EZ-C cryogenic valves (bulletin D102189X012), Neles BWX cryogenic high-performance butterfly valves (manual 2bwx70en), SAMSON cryogenic control valves; specific models subject to official selection.

If you are reviewing control valve selection for a process unit, please send us the medium, temperature, pressure, size and signal requirements. We can review the selection dimensions together against the official catalogue and design conditions.

Orders & Inquiries

Baoman Industrial Technology (Chengdu) Co., Ltd
Tel: +86 028-60220547 | Email: info@bit-cd.com
Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry.