The SAMSON 3730 series smart electropneumatic positioner uses a single rotary pushbutton for parameter selection and confirmation, with all values shown on an LCD whose reading direction can be rotated by 180 degrees. The DIP switch "Air to open / Air to close" sets the closing direction and the INIT key starts initialization. This article organizes local buttons, LCD indication and commissioning points according to the official SAMSON data sheets and operating instructions. Menus and parameters are subject to the official operating manual. I. Product Positioning
Reference: SAMSON data sheets T 8384-3/4/5 EN, NA 0122 and operating instructions. The 3730-6 (pressure monitoring) and flameproof 3731 series are separate designs covered by T 8384-6 EN and T 8387-3/5 EN respectively; their code tables are not reused here.
II. Local Buttons and LCD Indication
Local operation centres on "turn to select, press to confirm", with the DIP switch defining acting direction and the INIT key starting self-commissioning. After changing parameters, re-verify valve position and fail-safe position; LCD values alone do not prove correct action. Reference: SAMSON data sheet T 8384-5 EN (Operation: single rotary pushbutton, LCD, DIP switch, INIT key, 180-degree reading direction) and operating instructions; NE 107 classification per NAMUR NE 107. III. Initialization and Commissioning Flow
Initialization depends on pre-set parameters; a wrong DIP direction or limit setting will make the result deviate from actual service. After commissioning, confirm action with LCD status information and position feedback. Reference: SAMSON data sheet T 8384-5 EN (Operation and initialization) and operating instructions; specific steps are subject to the manual for the exact model. IV. Sub-series Differentiation
The 3730-6 is a separate design with supply/output pressure monitoring (T 8384-6 EN), and the 3731 series is the flameproof Ex d version (T 8387-3/5 EN). Both use different ordering-code lengths and digit layouts; the 3730 code table must not be applied to them. Reference: SAMSON data sheets T 8384-3/4/5 EN, T 8384-6 EN, T 8387-3/5 EN and NA 0122; sub-series codes are subject to the official selection tool. V. LCD Status and Diagnostic Indication
Reference: SAMSON data sheets T 8384-3/4/5 EN (EXPERTplus diagnostics and NE 107 status messages); specific status texts are subject to the official operating manual. VI. Selection Guide and Common ModelsSelection guide: Decide the sub-series by communication first (no-communication 3730-0/1/2, HART 3730-3, PA 3730-4, FF 3730-5), then fill the Ex digits per certification requirements (this series is mainly intrinsically safe with no flameproof version; use the 3731 series for flameproof), then add feedback, switches, solenoid valves and other options as required, and finally use the official selection tool to generate the complete ordering code. Unconfirmed items are subject to the official manual; do not infer menus. Common models: 3730-3 (HART, widely used), 3730-1/3730-2 (no-communication digital types), 3730-4 (PROFIBUS PA), 3730-5 (FF); related separate series include 3730-6 (pressure monitoring) and 3731-3/3731-5 (flameproof). Ordering codes and menus are subject to the official selection tool and operating manual. If you are reviewing 3730 local button operation or initialization, please share the sub-series, acting form and mounting standard. We can review the parameters and menu practice together against the official data sheet. Orders & InquiriesBaoman Industrial Technology (Chengdu) Co., LtdTel: +86 028-60220547 | Email: info@bit-cd.com Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry. |