Home » News Center » Product Arrival Display
Fisher i2P-100 Electro-Pneumatic Transducer - Arrival Photos & Data
Fisher i2P-100 Electro-Pneumatic Transducer - Arrival Photos & Data
Fisher i2P-100 Electro-Pneumatic Transducer - Arrival Photos & Data
Fisher i2P-100 Electro-Pneumatic Transducer - Arrival Photos & Data
Fisher i2P-100 Electro-Pneumatic Transducer - Arrival Photos & Data

Fisher i2P-100 Electro-Pneumatic Transducer - Arrival Photos & Data

Details

1. Product Overview

Fisher i2P-100 Electro-Pneumatic Transducer - Arrival Photos & Data. The Fisher i2P-100 is an electro pneumatic converter that accepts a 4 to 20 mA DC input signal and converts it to a pneumatic output for actuator control. A dip switch splits the input range into 4 to 12 mA or 12 to 20 mA, and selectable output ranges are 0.2 to 1.0 bar, 0.4 to 2.0 bar and 0.14 to 2.3 bar. Reference accuracy is plus or minus 1.0 percent of full scale including hysteresis, linearity and dead band, with independent linearity of 0.5 percent and hysteresis of 0.4 percent. The supply medium can be air or natural gas at up to 3.4 bar, and it should be at least 0.3 bar above the output upper limit. Operating temperature spans minus 40 to 85 degrees C. Electrical connection is half inch NPT, while supply, output and exhaust connections are quarter inch NPT, and the unit weighs 2.5 kg. Approvals include CSA Class 4X and 3X, FM NEMA 4X and 3, ATEX IP66 and IP64 and IECEx IP66 and IP64. The family also includes the 646 basic model with plus or minus 0.5 percent accuracy and air only, the 846 with electronic self calibration, multiple ranges and plus or minus 0.30 percent accuracy, and the 546NS nuclear qualified version.

Official specifications are listed in the table below; values not published in official literature are not assumed.

Product photo

Product photo

Product photo

Product photo

Product photo

Above: product appearance / as-delivered photos (desensitized and watermarked, or official manufacturer images).

2. Technical Description

Technical description: The Fisher i2P-100 is an electro pneumatic converter that accepts a 4 to 20 mA DC input signal and converts it to a pneumatic output for actuator control. A dip switch splits the input range into 4 to 12 mA or 12 to 20 mA, and selectable output ranges are 0.2 to 1.0 bar, 0.4 to 2.0 bar and 0.14 to 2.3 bar. Reference accuracy is plus or minus 1.0 percent of full scale including hysteresis, linearity and dead band, with independent linearity of 0.5 percent and hysteresis of 0.4 percent. The supply medium can be air or natural gas at up to 3.4 bar, and it should be at least 0.3 bar above the output upper limit. Operating temperature spans minus 40 to 85 degrees C. Electrical connection is half inch NPT, while supply, output and exhaust connections are quarter inch NPT, and the unit weighs 2.5 kg. Approvals include CSA Class 4X and 3X, FM NEMA 4X and 3, ATEX IP66 and IP64 and IECEx IP66 and IP64. The family also includes the 646 basic model with plus or minus 0.5 percent accuracy and air only, the 846 with electronic self calibration, multiple ranges and plus or minus 0.30 percent accuracy, and the 546NS nuclear qualified version.

3. Key Technical Specifications

ParameterSpecification / Description
SpecificationThe Fisher i2P-100 is an electro pneumatic converter that accepts a 4 to 20 mA DC input signal and converts it to a pneumatic output for actuator control
SpecificationA dip switch splits the input range into 4 to 12 mA or 12 to 20 mA
Specificationand selectable output ranges are 0.2 to 1.0 bar
Specification0.4 to 2.0 bar and 0.14 to 2.3 bar
SpecificationReference accuracy is plus or minus 1.0 percent of full scale including hysteresis
Linearitylinearity and dead band
Specificationwith independent linearity of 0.5 percent and hysteresis of 0.4 percent
SpecificationThe supply medium can be air or natural gas at up to 3.4 bar
Specificationand it should be at least 0.3 bar above the output upper limit
Operating temperatureOperating temperature spans minus 40 to 85 degrees C
SpecificationElectrical connection is half inch NPT
Specificationwhile supply
Specificationoutput and exhaust connections are quarter inch NPT
Specificationand the unit weighs 2.5 kg
SpecificationApprovals include CSA Class 4X and 3X
SpecificationFM NEMA 4X and 3
Explosion protectionATEX IP66 and IP64 and IECEx IP66 and IP64
SpecificationThe family also includes the 646 basic model with plus or minus 0.5 percent accuracy and air only
Product familythe 846 with electronic self calibration
Specificationmultiple ranges and plus or minus 0.30 percent accuracy
Specificationand the 546NS nuclear qualified version

4. Selection Quick Reference (Ordering Code by Position)

ItemDescription
Ordering and full model enumerationModels covered: P-100. For complete ordering codes and digit-by-digit definitions, refer to the official data sheet in the source section; verify with the manufacturer.

5. Complete Model Enumeration

No other models in this series in this batch.

6. Related Models

No related models in this batch.

7. Common Spare Parts

Spare partDescription
Seat / trim kitBy size and material; refer to the latest official literature; verify with the manufacturer
Stem packing / seal kitBy valve type and medium; verify with the manufacturer
Guide bushingWear part, by size; verify with the manufacturer
Gasket / O-ring kitBy body material and medium; verify with the manufacturer

8. Accessories

AccessoryDescription
Pneumatic / electric actuatorSelected by torque and duty, with positioner
Valve positioner4-20 mA HART / fieldbus, by single/double acting and linear/rotary
Limit switch / position feedbackSPDT or NAMUR, by explosion protection and ingress rating
Filter regulator / air setStable air supply for pneumatic actuators, by port and flow

9. Disclaimer

The information above is not guaranteed to remain current; changes may be made without prior notice. Please confirm the latest information at the time of inquiry. Certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources and Contact

Source: Fisher official literature: D103198X0CN; D101351X0CN; D102005X0CN; D103425X0CN..

We supply the above models, spare parts and accessories. For selection or supply inquiries, please contact: +86 028-60220547 | info@bit-cd.com

Ordering & Inquiry

The photos above show the models currently in stock. If you are working through a similar selection, or would like to know more about a model's configuration and availability, feel free to get in touch — we can look at the right combination together based on your valve type and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area