Fisher DLC3100 Digital Level Transmitter - Arrival Photos & Data
1. Product Overview
Fisher DLC3100 Digital Level Transmitter - Arrival Photos & Data. The Fisher DLC3100 is a digital level transmitter that uses a floating displacer for level, interface and density service. Buoyancy acting on the displacer produces torque tube rotation of up to 4.4 degrees, and a Hall effect sensor detects that rotation and converts it into a digital signal. The output is 4 to 20 mA with HART 5 or HART 7 and NAMUR NE43 alarm currents, powered by 12 to 30 V DC at 25 mA with a 17.75 V minimum for HART. Independent linearity ranges from plus or minus 0.25 percent for an NPS 3, 14 inch displacer to plus or minus 0.8 percent for other 249 configurations and plus or minus 0.5 percent for the 249W, with repeatability of plus or minus 0.1 to 0.5 percent of full scale, hysteresis below 0.2 percent of output and dead band below 0.05 percent. Ambient temperature range is minus 40 to 80 degrees C and the LCD operates from minus 20 to 70 degrees C. Protection is IP66 and Type 4X, with two half inch 14 NPT connections and weight up to 3.45 kg. Approvals include CSA Ex ia and Ex d, SIL 2, ATEX, IECEx, CML, CUTR, NEPSI and PESO. A DLC3100 SIS variant is available for safety instrumented systems. Wetted parts depend on the 249 sensor fitted.
Official specifications are listed in the table below; values not published in official literature are not assumed.



2. Technical Description
Technical description: The Fisher DLC3100 is a digital level transmitter that uses a floating displacer for level, interface and density service. Buoyancy acting on the displacer produces torque tube rotation of up to 4.4 degrees, and a Hall effect sensor detects that rotation and converts it into a digital signal. The output is 4 to 20 mA with HART 5 or HART 7 and NAMUR NE43 alarm currents, powered by 12 to 30 V DC at 25 mA with a 17.75 V minimum for HART. Independent linearity ranges from plus or minus 0.25 percent for an NPS 3, 14 inch displacer to plus or minus 0.8 percent for other 249 configurations and plus or minus 0.5 percent for the 249W, with repeatability of plus or minus 0.1 to 0.5 percent of full scale, hysteresis below 0.2 percent of output and dead band below 0.05 percent. Ambient temperature range is minus 40 to 80 degrees C and the LCD operates from minus 20 to 70 degrees C. Protection is IP66 and Type 4X, with two half inch 14 NPT connections and weight up to 3.45 kg. Approvals include CSA Ex ia and Ex d, SIL 2, ATEX, IECEx, CML, CUTR, NEPSI and PESO. A DLC3100 SIS variant is available for safety instrumented systems. Wetted parts depend on the 249 sensor fitted.
3. Key Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Specification | The Fisher DLC3100 is a digital level transmitter that uses a floating displacer for level |
| Specification | interface and density service |
| Specification | Buoyancy acting on the displacer produces torque tube rotation of up to 4.4 degrees |
| Specification | and a Hall effect sensor detects that rotation and converts it into a digital signal |
| Specification | The output is 4 to 20 mA with HART 5 or HART 7 and NAMUR NE43 alarm currents |
| Power supply | powered by 12 to 30 V DC at 25 mA with a 17.75 V minimum for HART |
| Specification | Independent linearity ranges from plus or minus 0.25 percent for an NPS 3 |
| Specification | 14 inch displacer to plus or minus 0.8 percent for other 249 configurations and plus or minus 0.5 percent for the 249W |
| Specification | with repeatability of plus or minus 0.1 to 0.5 percent of full scale |
| Hysteresis | hysteresis below 0.2 percent of output and dead band below 0.05 percent |
| Temperature | Ambient temperature range is minus 40 to 80 degrees C and the LCD operates from minus 20 to 70 degrees C |
| Specification | Protection is IP66 and Type 4X |
| Specification | with two half inch 14 NPT connections and weight up to 3.45 kg |
| Specification | Approvals include CSA Ex ia and Ex d |
| Specification | SIL 2 |
| Explosion protection | ATEX |
| Explosion protection | IECEx |
| Specification | CML |
| Specification | CUTR |
| Specification | NEPSI and PESO |
| Specification | A DLC3100 SIS variant is available for safety instrumented systems |
| Materials | Wetted parts depend on the 249 sensor fitted |
4. Selection Quick Reference (Ordering Code by Position)
| Item | Description |
|---|---|
| Ordering and full model enumeration | Models covered: DLC3100. For complete ordering codes and digit-by-digit definitions, refer to the official data sheet in the source section; verify with the manufacturer. |
5. Complete Model Enumeration
No other models in this series in this batch.
6. Related Models
No related models in this batch.
7. Common Spare Parts
| Spare part | Description |
|---|---|
| Seat / trim kit | By size and material; refer to the latest official literature; verify with the manufacturer |
| Stem packing / seal kit | By valve type and medium; verify with the manufacturer |
| Guide bushing | Wear part, by size; verify with the manufacturer |
| Gasket / O-ring kit | By body material and medium; verify with the manufacturer |
8. Accessories
| Accessory | Description |
|---|---|
| Pneumatic / electric actuator | Selected by torque and duty, with positioner |
| Valve positioner | 4-20 mA HART / fieldbus, by single/double acting and linear/rotary |
| Limit switch / position feedback | SPDT or NAMUR, by explosion protection and ingress rating |
| Filter regulator / air set | Stable air supply for pneumatic actuators, by port and flow |
9. Disclaimer
The information above is not guaranteed to remain current; changes may be made without prior notice. Please confirm the latest information at the time of inquiry. Certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources and Contact
We supply the above models, spare parts and accessories. For selection or supply inquiries, please contact: +86 028-60220547 | info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文
ENGLISH