Home » Products » Fuji Electric
Fuji Electric ZKJ Infrared Zirconia Gas Analyzer
Fuji Electric ZKJ Infrared Zirconia Gas Analyzer
Fuji Electric ZKJ Infrared Zirconia Gas Analyzer

Fuji Electric ZKJ Infrared Zirconia Gas Analyzer

Details

1. Product Overview

Fuji Electric ZKJ Infrared Zirconia Gas Analyzer. The ZKJ zirconia-configured variant combines double-beam NDIR measurement of NO, SO2, CO2, CO, CH4 and N2O with an external ZFK7 zirconia oxygen sensor. Oxygen is measured by the zirconia sensor, while the infrared channels use a mass-flow twin detector that limits interference from other gases. The ZFK7 provides a reproducibility of ±0.5% FS and a 90% response time of about 20 seconds. The analyzer supports oxygen-corrected outputs, averaging and automatic calibration. It is intended for combustion flue gas monitoring in incinerators, industrial furnaces and boilers.

Official specifications are listed in the table below; values not published in official literature are not assumed.

Product photo

Product photo

Product photo

Above: product appearance / as-delivered photos (desensitized and watermarked, or official manufacturer images).

2. Technical Description

Technical description: The ZKJ zirconia-configured variant combines double-beam NDIR measurement of NO, SO2, CO2, CO, CH4 and N2O with an external ZFK7 zirconia oxygen sensor. Oxygen is measured by the zirconia sensor, while the infrared channels use a mass-flow twin detector that limits interference from other gases. The ZFK7 provides a reproducibility of ±0.5% FS and a 90% response time of about 20 seconds. The analyzer supports oxygen-corrected outputs, averaging and automatic calibration. It is intended for combustion flue gas monitoring in incinerators, industrial furnaces and boilers.

3. Key Technical Specifications

ParameterSpecification / Description
SpecificationThe ZKJ zirconia-configured variant combines double-beam NDIR measurement of NO
SpecificationSO2
SpecificationCO2
SpecificationCO
SpecificationCH4 and N2O with an external ZFK7 zirconia oxygen sensor
SpecificationOxygen is measured by the zirconia sensor
Specificationwhile the infrared channels use a mass-flow twin detector that limits interference from other gases
Product familyThe ZFK7 provides a reproducibility of ±0.5% FS and a 90% response time of about 20 seconds
SpecificationThe analyzer supports oxygen-corrected outputs
Specificationaveraging and automatic calibration
SpecificationIt is intended for combustion flue gas monitoring in incinerators
Specificationindustrial furnaces and boilers

4. Selection Quick Reference (Ordering Code by Position)

ItemDescription
Ordering and full model enumerationModels covered: . For complete ordering codes and digit-by-digit definitions, refer to the official data sheet in the source section; verify with the manufacturer.

5. Complete Model Enumeration

No other models in this series in this batch.

6. Related Models

No related models in this batch.

7. Common Spare Parts

Spare partDescription
Seat / trim kitBy size and material; refer to the latest official literature; verify with the manufacturer
Stem packing / seal kitBy valve type and medium; verify with the manufacturer
Guide bushingWear part, by size; verify with the manufacturer
Gasket / O-ring kitBy body material and medium; verify with the manufacturer

8. Accessories

AccessoryDescription
Pneumatic / electric actuatorSelected by torque and duty, with positioner
Valve positioner4-20 mA HART / fieldbus, by single/double acting and linear/rotary
Limit switch / position feedbackSPDT or NAMUR, by explosion protection and ingress rating
Filter regulator / air setStable air supply for pneumatic actuators, by port and flow

9. Disclaimer

The information above is not guaranteed to remain current; changes may be made without prior notice. Please confirm the latest information at the time of inquiry. Certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources and Contact

Source: Fuji Electric official literature: anlz_gas_zkj; 21C1-E-0068. Official product pages: https://www.fujielectric.com/products/sensors_measurements/instruments/product_detail/anlz_gas_zkj.html, https://americas.fujielectric.com/wp-content/uploads/2018/04/21C1-E-0068.pdf..

We supply the above models, spare parts and accessories. For selection or supply inquiries, please contact: +86 028-60220547 | info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area