Fuji Electric FWD Air Ultrasonic Flowmeter
1. Product Overview
Fuji Electric FWD Air Ultrasonic Flowmeter. The Fuji Electric FWD is an ultrasonic flowmeter for air and nitrogen in pipes from 25 to 200 mm, intended for compressor monitoring and factory air management. It uses the transit-time method with no obstruction in the pipe, so there is no pressure loss, and it tolerates oil mist without a separate mist separator. Versions are available with 24 V DC supply or an internal lithium battery with an approximate ten year life at 20 degrees Celsius. Flow range depends on pipe size, from plus or minus 0.6 to 35 cubic meters per hour for 25 mm up to plus or minus 40 to 2000 cubic meters per hour for 200 mm, with accuracy of plus or minus 2 percent of rate over the upper part of each range. The meter supports forward and reverse measurement, air leakage detection and conversion to normal or standard flow conditions.
Official specifications are listed in the table below; values not published in official literature are not assumed.



2. Technical Description
Technical description: The Fuji Electric FWD is an ultrasonic flowmeter for air and nitrogen in pipes from 25 to 200 mm, intended for compressor monitoring and factory air management. It uses the transit-time method with no obstruction in the pipe, so there is no pressure loss, and it tolerates oil mist without a separate mist separator. Versions are available with 24 V DC supply or an internal lithium battery with an approximate ten year life at 20 degrees Celsius. Flow range depends on pipe size, from plus or minus 0.6 to 35 cubic meters per hour for 25 mm up to plus or minus 40 to 2000 cubic meters per hour for 200 mm, with accuracy of plus or minus 2 percent of rate over the upper part of each range. The meter supports forward and reverse measurement, air leakage detection and conversion to normal or standard flow conditions.
3. Key Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Specification | The Fuji Electric FWD is an ultrasonic flowmeter for air and nitrogen in pipes from 25 to 200 mm |
| Specification | intended for compressor monitoring and factory air management |
| Specification | It uses the transit-time method with no obstruction in the pipe |
| Specification | so there is no pressure loss |
| Specification | and it tolerates oil mist without a separate mist separator |
| Specification | Versions are available with 24 V DC supply or an internal lithium battery with an approximate ten year life at 20 degrees Celsius |
| Flow capacity | Flow range depends on pipe size |
| Specification | from plus or minus 0.6 to 35 cubic meters per hour for 25 mm up to plus or minus 40 to 2000 cubic meters per hour for 200 mm |
| Specification | with accuracy of plus or minus 2 percent of rate over the upper part of each range |
| Specification | The meter supports forward and reverse measurement |
| Specification | air leakage detection and conversion to normal or standard flow conditions |
4. Selection Quick Reference (Ordering Code by Position)
| Item | Description |
|---|---|
| Ordering and full model enumeration | Models covered: FWD025, FWD032, FWD040, FWD050, FWD065, FWD080, FWD100, FWD150, FWD200. For complete ordering codes and digit-by-digit definitions, refer to the official data sheet in the source section; verify with the manufacturer. |
5. Complete Model Enumeration
No other models in this series in this batch.
6. Related Models
No related models in this batch.
7. Common Spare Parts
| Spare part | Description |
|---|---|
| Seat / trim kit | By size and material; refer to the latest official literature; verify with the manufacturer |
| Stem packing / seal kit | By valve type and medium; verify with the manufacturer |
| Guide bushing | Wear part, by size; verify with the manufacturer |
| Gasket / O-ring kit | By body material and medium; verify with the manufacturer |
8. Accessories
| Accessory | Description |
|---|---|
| Pneumatic / electric actuator | Selected by torque and duty, with positioner |
| Valve positioner | 4-20 mA HART / fieldbus, by single/double acting and linear/rotary |
| Limit switch / position feedback | SPDT or NAMUR, by explosion protection and ingress rating |
| Filter regulator / air set | Stable air supply for pneumatic actuators, by port and flow |
9. Disclaimer
The information above is not guaranteed to remain current; changes may be made without prior notice. Please confirm the latest information at the time of inquiry. Certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources and Contact
We supply the above models, spare parts and accessories. For selection or supply inquiries, please contact: +86 028-60220547 | info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文
ENGLISH