Home » Products » Aventics
AVENTICS ED07 Electronic Pressure Regulator with High-Flow Exhaust
AVENTICS ED07 Electronic Pressure Regulator with High-Flow Exhaust
AVENTICS ED07 Electronic Pressure Regulator with High-Flow Exhaust

AVENTICS ED07 Electronic Pressure Regulator with High-Flow Exhaust

Details

1. Product Overview

AVENTICS ED07 Electronic Pressure Regulator with High-Flow Exhaust. The AVENTICS Series ED07 is a dynamic direct-acting E/P pressure regulator with a nominal width of 7. It provides proportional pressurization while the exhaust valve is controlled separately for demanding dynamic applications. The regulator offers a nominal flow of 1300 l/min and a series pressure range from -1 to 20 bar depending on the version. Analog versions accept 0-10 V or 0-20/4-20 mA signals, while fieldbus versions support EtherCAT. The unit operates on 24 V DC with a maximum current consumption of 1400 mA and an M12 connection. It is rated IP65 and carries a CE declaration of conformity.

Official specifications are listed in the table below; values not published in official literature are not assumed.

Product photo

Product photo

Product photo

Above: product appearance / as-delivered photos (desensitized and watermarked, or official manufacturer images).

2. Technical Description

Technical description: The AVENTICS Series ED07 is a dynamic direct-acting E/P pressure regulator with a nominal width of 7. It provides proportional pressurization while the exhaust valve is controlled separately for demanding dynamic applications. The regulator offers a nominal flow of 1300 l/min and a series pressure range from -1 to 20 bar depending on the version. Analog versions accept 0-10 V or 0-20/4-20 mA signals, while fieldbus versions support EtherCAT. The unit operates on 24 V DC with a maximum current consumption of 1400 mA and an M12 connection. It is rated IP65 and carries a CE declaration of conformity.

3. Key Technical Specifications

ParameterSpecification / Description
SpecificationThe AVENTICS Series ED07 is a dynamic direct-acting E/P pressure regulator with a nominal width of 7
SpecificationIt provides proportional pressurization while the exhaust valve is controlled separately for demanding dynamic applications
SpecificationThe regulator offers a nominal flow of 1300 l/min and a series pressure range from -1 to 20 bar depending on the version
SpecificationAnalog versions accept 0-10 V or 0-20/4-20 mA signals
Specificationwhile fieldbus versions support EtherCAT
SpecificationThe unit operates on 24 V DC with a maximum current consumption of 1400 mA and an M12 connection
SpecificationIt is rated IP65 and carries a CE declaration of conformity

4. Selection Quick Reference (Ordering Code by Position)

ItemDescription
Ordering and full model enumerationModels covered: ED07, ED07-000-100-ECAT-4M12X-EXT-DO, R414014314, ED07-000-020-420-1M12A, M12, R414014311, R414014312, R414000700. For complete ordering codes and digit-by-digit definitions, refer to the official data sheet in the source section; verify with the manufacturer.

5. Complete Model Enumeration

No other models in this series in this batch.

6. Related Models

No related models in this batch.

7. Common Spare Parts

Spare partDescription
Seat / trim kitBy size and material; refer to the latest official literature; verify with the manufacturer
Stem packing / seal kitBy valve type and medium; verify with the manufacturer
Guide bushingWear part, by size; verify with the manufacturer
Gasket / O-ring kitBy body material and medium; verify with the manufacturer

8. Accessories

AccessoryDescription
Pneumatic / electric actuatorSelected by torque and duty, with positioner
Valve positioner4-20 mA HART / fieldbus, by single/double acting and linear/rotary
Limit switch / position feedbackSPDT or NAMUR, by explosion protection and ingress rating
Filter regulator / air setStable air supply for pneumatic actuators, by port and flow

9. Disclaimer

The information above is not guaranteed to remain current; changes may be made without prior notice. Please confirm the latest information at the time of inquiry. Certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources and Contact

Source: AVENTICS official literature: catalog-series-ed07-aventics-en-6911838; aventics-ed07. Official product pages: https://www.emerson.com/documents/automation/catalog-series-ed07-aventics-en-6911838.pdf, https://www.emerson.com/en-mq/catalog/aventics-ed07..

We supply the above models, spare parts and accessories. For selection or supply inquiries, please contact: +86 028-60220547 | info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area