Home » Products » Aventics
AVENTICS NL4 Air Preparation Unit
AVENTICS NL4 Air Preparation Unit
AVENTICS NL4 Air Preparation Unit

AVENTICS NL4 Air Preparation Unit

Details

1. Product Overview

AVENTICS NL4 Air Preparation Unit. The AVENTICS Series NL4 is a high-flow modular air preparation family that can be used as individual components or assembled into blocks for centralized and decentralized compressed air conditioning. Available modules include two-part units, filter pressure regulators, standard regulators, microfilters, diaphragm dryers and pneumatic filling units. The NL4-FRE filter pressure regulator is offered with G 1/2 or G 3/4 ports, 5 µm filtration and a nominal flow of 6900 l/min at p2 = 6 bar and a 1 bar pressure drop. Working pressure ranges from 1.5 to 16 bar with an adjustment range of 0.5 to 10 bar and relieving exhaust. Options include lockable versions, pressure gauges, electrical level indicators and ATEX-suitable variants.

Official specifications are listed in the table below; values not published in official literature are not assumed.

Product photo

Product photo

Product photo

Above: product appearance / as-delivered photos (desensitized and watermarked, or official manufacturer images).

2. Technical Description

Technical description: The AVENTICS Series NL4 is a high-flow modular air preparation family that can be used as individual components or assembled into blocks for centralized and decentralized compressed air conditioning. Available modules include two-part units, filter pressure regulators, standard regulators, microfilters, diaphragm dryers and pneumatic filling units. The NL4-FRE filter pressure regulator is offered with G 1/2 or G 3/4 ports, 5 µm filtration and a nominal flow of 6900 l/min at p2 = 6 bar and a 1 bar pressure drop. Working pressure ranges from 1.5 to 16 bar with an adjustment range of 0.5 to 10 bar and relieving exhaust. Options include lockable versions, pressure gauges, electrical level indicators and ATEX-suitable variants.

3. Key Technical Specifications

ParameterSpecification / Description
SpecificationThe AVENTICS Series NL4 is a high-flow modular air preparation family that can be used as individual components or assembled into blocks for centralized and decentralized compressed air conditioning
SpecificationAvailable modules include two-part units
Filtrationfilter pressure regulators
Specificationstandard regulators
Specificationmicrofilters
Specificationdiaphragm dryers and pneumatic filling units
Product familyThe NL4-FRE filter pressure regulator is offered with G 1/2 or G 3/4 ports
Specification5 µm filtration and a nominal flow of 6900 l/min at p2 = 6 bar and a 1 bar pressure drop
SpecificationWorking pressure ranges from 1.5 to 16 bar with an adjustment range of 0.5 to 10 bar and relieving exhaust
SpecificationOptions include lockable versions
Specificationpressure gauges
Specificationelectrical level indicators and ATEX-suitable variants

4. Selection Quick Reference (Ordering Code by Position)

ItemDescription
Ordering and full model enumerationModels covered: R412007607. For complete ordering codes and digit-by-digit definitions, refer to the official data sheet in the source section; verify with the manufacturer.

5. Complete Model Enumeration

No other models in this series in this batch.

6. Related Models

No related models in this batch.

7. Common Spare Parts

Spare partDescription
Seat / trim kitBy size and material; refer to the latest official literature; verify with the manufacturer
Stem packing / seal kitBy valve type and medium; verify with the manufacturer
Guide bushingWear part, by size; verify with the manufacturer
Gasket / O-ring kitBy body material and medium; verify with the manufacturer

8. Accessories

AccessoryDescription
Pneumatic / electric actuatorSelected by torque and duty, with positioner
Valve positioner4-20 mA HART / fieldbus, by single/double acting and linear/rotary
Limit switch / position feedbackSPDT or NAMUR, by explosion protection and ingress rating
Filter regulator / air setStable air supply for pneumatic actuators, by port and flow

9. Disclaimer

The information above is not guaranteed to remain current; changes may be made without prior notice. Please confirm the latest information at the time of inquiry. Certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources and Contact

Source: AVENTICS official literature: catalog-series-nl4-aventics-en-6911174; 0821302507_zho_CHN. Official product pages: https://www.emerson.com/documents/automation/catalog-series-nl4-aventics-en-6911174.pdf, https://emersoncatalog.z1.web.core.windows.net/pdf/0821302507_zho_CHN.PDF..

We supply the above models, spare parts and accessories. For selection or supply inquiries, please contact: +86 028-60220547 | info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area