Home » Products » Aventics
AVENTICS AF2 Air Flow Sensor
AVENTICS AF2 Air Flow Sensor
AVENTICS AF2 Air Flow Sensor

AVENTICS AF2 Air Flow Sensor

Details

1. Product Overview

AVENTICS AF2 Air Flow Sensor. The AVENTICS Series AF2 flow sensors monitor air consumption in pneumatic systems, enabling rapid intervention in the event of leakage, optimizing energy use, preventing machine downtime and cutting costs. Using a calorimetric measuring principle, the sensors are available with IO-Link or Ethernet interfaces and measure compressed air at 0.5 to 100 m/s in the standard range and up to 150 m/s in the extended range, in accordance with ISO 8778. Working pressure ranges from 0 to 16 bar with ambient and medium temperatures from -20 to 60 °C. IO-Link versions provide two analog outputs, two switching outputs, a frequency output and a pulse output, with IP65/IP67 protection. Accuracy is ±3% of reading in the standard range, with ±1.5% reproducibility, and an OLED display shows flow, pressure and temperature.

Official specifications are listed in the table below; values not published in official literature are not assumed.

Product photo

Product photo

Product photo

Above: product appearance / as-delivered photos (desensitized and watermarked, or official manufacturer images).

2. Technical Description

Technical description: The AVENTICS Series AF2 flow sensors monitor air consumption in pneumatic systems, enabling rapid intervention in the event of leakage, optimizing energy use, preventing machine downtime and cutting costs. Using a calorimetric measuring principle, the sensors are available with IO-Link or Ethernet interfaces and measure compressed air at 0.5 to 100 m/s in the standard range and up to 150 m/s in the extended range, in accordance with ISO 8778. Working pressure ranges from 0 to 16 bar with ambient and medium temperatures from -20 to 60 °C. IO-Link versions provide two analog outputs, two switching outputs, a frequency output and a pulse output, with IP65/IP67 protection. Accuracy is ±3% of reading in the standard range, with ±1.5% reproducibility, and an OLED display shows flow, pressure and temperature.

3. Key Technical Specifications

ParameterSpecification / Description
SpecificationThe AVENTICS Series AF2 flow sensors monitor air consumption in pneumatic systems
Specificationenabling rapid intervention in the event of leakage
Specificationoptimizing energy use
Specificationpreventing machine downtime and cutting costs
SpecificationUsing a calorimetric measuring principle
Specificationthe sensors are available with IO-Link or Ethernet interfaces and measure compressed air at 0.5 to 100 m/s in the standard range and up to 150 m/s in the extended range
Specificationin accordance with ISO 8778
SpecificationWorking pressure ranges from 0 to 16 bar with ambient and medium temperatures from -20 to 60 °C
SpecificationIO-Link versions provide two analog outputs
Specificationtwo switching outputs
Specificationa frequency output and a pulse output
Specificationwith IP65/IP67 protection
AccuracyAccuracy is ±3% of reading in the standard range
Specificationwith ±1.5% reproducibility
Specificationand an OLED display shows flow
Specificationpressure and temperature

4. Selection Quick Reference (Ordering Code by Position)

ItemDescription
Ordering and full model enumerationModels covered: R412026834, W05, R412028645, R412028647, R412026496. For complete ordering codes and digit-by-digit definitions, refer to the official data sheet in the source section; verify with the manufacturer.

5. Complete Model Enumeration

No other models in this series in this batch.

6. Related Models

No related models in this batch.

7. Common Spare Parts

Spare partDescription
Seat / trim kitBy size and material; refer to the latest official literature; verify with the manufacturer
Stem packing / seal kitBy valve type and medium; verify with the manufacturer
Guide bushingWear part, by size; verify with the manufacturer
Gasket / O-ring kitBy body material and medium; verify with the manufacturer

8. Accessories

AccessoryDescription
Pneumatic / electric actuatorSelected by torque and duty, with positioner
Valve positioner4-20 mA HART / fieldbus, by single/double acting and linear/rotary
Limit switch / position feedbackSPDT or NAMUR, by explosion protection and ingress rating
Filter regulator / air setStable air supply for pneumatic actuators, by port and flow

9. Disclaimer

The information above is not guaranteed to remain current; changes may be made without prior notice. Please confirm the latest information at the time of inquiry. Certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources and Contact

Source: AVENTICS official literature: catalog-series-af2-aventics-en-6916374; R412027180_zho_CHN; monteringsanvisning-fl%C3%B6dessensor-af2-aventics-sv-10107780.pdf%E3%80%82. Official product pages: https://www.emerson.com/documents/automation/catalog-series-af2-aventics-en-6916374.pdf, https://emersoncatalog.z1.web.core.windows.net/pdf/R412027180_zho_CHN.PDF, https://www.emerson.com/documents/automation/monteringsanvisning-fl%C3%B6dessensor-af2-aventics-sv-10107780.pdf%E3%80%82..

We supply the above models, spare parts and accessories. For selection or supply inquiries, please contact: +86 028-60220547 | info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area