Fisher digital positioners generally carry NEMA 4X / IP66 enclosures for protection against dust, rain, water spray and corrosion. However, an enclosure rating is not the same as a material rating: corrosive service also depends on housing material, coating and elastomers. This article organizes rating meanings, DVC6200 enclosure configuration and corrosive-environment selection according to official catalogues. Ratings and certifications are subject to the nameplate and official manual.

I. Product Positioning

ItemDescription
Brand and ownershipFisher (a brand of Emerson)
SubjectFisher FIELDVUE DVC6200 / DVC7K digital positioner enclosures
Enclosure ratingCSA/FM Type 4X, IP66; ATEX/IECEx IP66
StandardsNEMA 250 (Type 4X), IEC 60529 (IP66)
MaterialsA03600 low-copper aluminium (standard); stainless steel optional; thermoplastic polyester cover; nitrile/fluorosilicone elastomers
Ambient temperatureStandard -40 to +85 degC; extreme fluorosilicone -52 to +85 degC; remote feedback unit -52 to +125 degC
Key documentsEmerson/Fisher manuals D103409X012, D103557X012, bulletins D104363X0CN / D104765X012

Reference: Emerson/Fisher manuals D103409X012 and D103557X012, bulletins D104363X0CN and D104765X012; ratings per NEMA 250 and IEC 60529, subject to the nameplate.

Fisher digital positioner enclosure reference
Appearance reference only, not the actual model; parameters subject to the official catalogue.

II. Enclosure Rating Meanings

RatingMeaningTypical scenario
NEMA Type 4XDust and windblown dust protection, rain, splashing water, hose-directed water and ice, with corrosion resistanceOutdoor, wash-down, coastal or mild corrosive areas
IP66Dust-tight (6); protected against powerful water jets (6)Outdoor, dusty and powerful jet-water locations
IP67 (some options)Dust-tight; temporary immersionSpecial locations with possible temporary immersion, confirm official options
Type 4X vs IP66Different test systems; not directly convertibleCheck nameplate markings separately; neither replaces the other
Corrosion4X emphasizes corrosion-resistant enclosure; IP codes do not include corrosion ratingCorrosive service needs separate check of housing material and coating
Explosion protectionEnclosure rating and Ex certification are separate systemsEx ia / Ex d certifications verified separately on the nameplate

An enclosure rating describes protection against solid objects and water, not chemical corrosion resistance. Explosion protection (intrinsic safety Ex ia, flameproof Ex d) is yet another system. All three must be verified separately; IP66 alone does not imply any particular Ex or corrosion rating.

Reference: NEMA 250 and IEC 60529 standard definitions; Emerson/Fisher catalogues D103409X012 and D103557X012. Certifications are subject to the nameplate and certificates; verify with the manufacturer if unconfirmed.

III. DVC6200 Enclosure Configuration

ItemStandard / optionDescription
Housing materialStandard A03600 low-copper aluminium; stainless steel optionalOrdering code field 2 distinguishes aluminium / stainless
Housing typeHousing B (standard design); housing A (integral aluminium, for GX valves only)Ordering code field 3 distinguishes types
CoverThermoplastic polyesterTransparent window and protective cover
ElastomersNitrile (standard); fluorosilicone (extreme temperature)Affects low- and high-temperature range
Electrical interface1/2 NPT; M20 optionalConduit and cable gland must preserve the rating
Enclosure ratingType 4X / IP66Valid only when fully assembled with plugs installed

The rating is valid only when all conduit openings, covers and seals are installed as specified; unused openings must be closed with certified plugs. Opening the cover or removing plugs on site invalidates the rating until restored.

Reference: Emerson/Fisher bulletin D104363X0CN and manuals D103409X012, D103557X012 (SIS housing/materials). Ordering codes are subject to the official catalogue.

IV. Corrosive-Environment Selection Dimensions

EnvironmentRiskSelection direction
Coastal / marineSalt-spray corrosionStainless housing or enhanced corrosion coating, 316 fittings
Chemical atmosphereAcidic / alkaline gasesStainless housing and corrosion-resistant elastomers per medium
Wash-down areaHigh-pressure waterType 4X / IP66 with complete glands and plugs
Dusty areaDust ingressIP66 dust-tight, sealed conduit openings
Low / high temperatureElastomer ageingFluorosilicone extreme-temperature option; verify temperature range
VibrationLoose fastenersTighten per official instructions; inspect seals periodically

The DVC7K also offers conformal-coated electronics per ISA-S75.13 and a weatherproof enclosure for vibration, temperature and corrosive environments; the exact coating and corrosion options are subject to its product bulletin.

Reference: Emerson/Fisher bulletin D104765X012 (DVC7K conformal coating and weatherproof enclosure) and D104363X0CN; corrosive selection is subject to the official catalogue and site specifications.

V. Installation and Maintenance Checklist

StageCheck items
UnpackingCheck nameplate rating, housing material and Ex markings
InstallationPoint conduits downward or sideways down; match gland to cable diameter
PluggingClose unused openings with certified plugs, number and location per manual
SealingCover gasket seated, bolts tightened evenly to the manual torque
MaintenanceInspect gasket after opening; confirm rating restored after reassembly
RecordsRecord rating, plug list and inspection date

Reference: Emerson/Fisher manual D103409X012; torque and seals are subject to the official manual.

VI. Selection Guide and Common Models

Selection guide: Decide whether Type 4X / IP66 is needed for dust and water first, then choose aluminium or stainless housing and coating by medium corrosiveness, then elastomers by temperature range, and finally determine the Ex certification by hazardous area and check the nameplate. Enclosure rating, corrosion resistance and Ex certification are three independent sets of specifications and cannot substitute for each other. Unconfirmed items are subject to the nameplate and official manual.

Common models: DVC6200 (Type 4X / IP66, aluminium or stainless housing), DVC6200 SIS (IP66, low-bleed relay), DVC7K (IP66 / Type 4X, conformal coating option). Ordering codes, housing types and certifications are subject to the official catalogue and nameplate.

If you are selecting an enclosure for outdoor or corrosive service, please share the medium, installation location and certification requirements. We can review the rating and housing material together against the official catalogue.

Orders & Inquiries

Baoman Industrial Technology (Chengdu) Co., Ltd
Tel: +86 028-60220547 | Email: info@bit-cd.com
Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry.