Home » Service & Support » Technical Documentation
Positioner & Actuator Mechanical Mounting Interfaces
Release time:2026-11-27 23:56:05 | Views:

The mechanical interface between a positioner and an actuator determines the reliability of feedback sensing, air connection and accessory expansion. Common interfaces include direct mounting, NAMUR (IEC 60534-6-1), VDI/VDE 3845 for rotary service and VDI/VDE 3847 for quick replacement. A wrong interface causes unsynchronized feedback, air leakage or positioner oscillation. This article organizes interface types, mounting points and a checklist from a general-structure perspective; dimensions are subject to the official catalogue.

I. Product Positioning

ItemContent
Interface functionMount the positioner, pick up valve position feedback and connect the signal air circuit
Main interfacesDirect mount (dedicated bracket) / NAMUR (IEC 60534-6-1) / VDI/VDE 3845 / VDI/VDE 3847
Feedback methodsFeedback lever with pin or follower plate, non-contact magnetic array, rack and pinion
Air circuitInternal drilling or connector block plus external tubing, with switching plate and blanks
Main documentsSAMSON EB 8394 ZH; Fisher DVC6200 catalogue; Flowserve FCD LGENIM0105-16

Sources: SAMSON official instruction EB 8394 ZH and 3730-3 operating instruction; Emerson/Fisher official catalogues DVC6200 and D103295X012; Flowserve official manual FCD LGENIM0105-16; interface standards IEC 60534-6-1, VDI/VDE 3845/3847 and ISO 5211.

Positioner and actuator interface illustration
Digital positioner illustration, not the actual model; parameters subject to the official catalogue

II. Interface Types

InterfaceDescription
Direct mountPositioner bolted directly to the small actuator bracket, feedback lever bears on the follower clamp by spring force, e.g. SAMSON 3277 with 3730
NAMUR (IEC 60534-6-1)Mounted using a NAMUR bracket or bent plate; follower pin enters the follower plate slot
VDI/VDE 3845Mounting face for quarter-turn actuators, used for 90-degree feedback
VDI/VDE 3847Includes an air blocker for quick positioner replacement while pressurized
Universal bracketExtended follower plate or flipped take-off arm selected by actuator size

Sources: SAMSON official instruction EB 8394 ZH and 3730-3 operating instruction (VDI/VDE 3847-1); Flowserve official manual FCD LGENIM0105-16 (linear NAMUR per IEC 534 part 6).

III. Mounting Points

PointDescription
Mid-stroke mountingPlace the actuator at mid stroke before fixing the follower plate or bent plate so the slot is centred
Feedback lever loadThe feedback lever must bear on the follower clamp by spring force, never float
Clamping screw in grooveThe follower clamp fixing screw must sit in the push rod groove
Pin positionChoose pin position such as 35 or 50 by actuator area or travel
Air switchingSelect internal drilling or external tubing for stem-extend or stem-retract action and align the switching plate mark
Vent plug downwardCover vent plug should face downward to drain condensate

Sources: SAMSON official instruction EB 8394 ZH (pin positions 35/50, switching plate, vent plug); 3730-3 operating instruction.

IV. Air Circuit and Accessory Expansion

PointDescription
Port blankingBlank off unused output ports to prevent leakage
Gauge connector blockFit a plain connector plate or one with a gauge; mind the seals
Solenoid valveWhen added, block the internal rear passage and route output through the connector plate
Spring chamber purgeVDI/VDE 3847 allows the Y2 port to purge the spring chamber
Lock-up and quick exhaustInstall per ESD or position-holding requirements
Limit feedbackInductive limit switches or position transmitters can be added

Sources: SAMSON official instruction EB 8394 ZH and 3730-3 operating instruction; Flowserve official manual FCD LGENIM0105-16.

V. Selection Checks

Check itemDescription
Acting formPositioner single- or double-acting must match the actuator
Travel or angleCheck linear travel or rotary angle range and select the matching feedback variant
Interface standardConfirm NAMUR, VDI/VDE 3845, 3847 or ISO 5211
Air directionStem-extend or stem-retract action corresponds to internal drilling or external tubing
Accessory spaceSpace for gauge, solenoid valve and limit switches
Tightening torquePer official manual; 0.25 Nm in the Flowserve catalogue is an example value

Sources: Flowserve official manual FCD LGENIM0105-16 (maximum tightening torque 0.25 Nm); SAMSON official instruction EB 8394 ZH; specific torque subject to the official manual.

VI. Selection Guide and Common Models

Selection guide: First confirm the available mechanical interface (direct mount, NAMUR, 3845 or 3847) from the actuator brand and model, then select the feedback variant and pin position by linear or rotary travel and range. Next set the air switching direction from the fail-safe action and blank unused ports, and finally check accessory space and tightening torque. Where official confirmation is unavailable, refer to the official catalogue or nameplate; do not guess parameters.

Common models: SAMSON 3730 with direct mount or NAMUR on 3277 (EB 8394 ZH) and VDI/VDE 3847 quick replacement; Emerson Fisher DVC6200 with 585C and 2052 (D103295X012); Flowserve Logix 520MD+ linear NAMUR (FCD LGENIM0105-16); Masoneilan, ABB and SMC digital positioners use their own mounting kits. These are public product series examples; mounting kit ordering numbers subject to the official catalogue.

If you are reviewing the mechanical interface between an actuator and a valve, please send us the acting form, mounting arrangement, connection and accessory requirements. We can review the model and installation details together against the official catalogue.

Orders & Inquiries

Baoman Industrial Technology (Chengdu) Co., Ltd
Tel: +86 028-60220547 | Email: info@bit-cd.com
Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China