Large-Bore Valves - Twin Actuator Parallel Configuration
Release time:2026-11-27 23:56:05 | Views:

Large-bore, high-differential-pressure valves may need more torque than a single actuator can deliver, or more output at a limited air supply pressure. In such cases two actuators can be arranged in parallel to drive the same valve shaft. The essentials are torque synchronization, mechanical linkage and air capacity matching; otherwise internal forces, binding and out-of-step motion may result. This article organizes configuration forms, synchronization points and a checklist from a general-structure perspective; specific schemes require manufacturer confirmation.

I. Product Positioning

ItemContent
ApplicationLarge-bore ball or butterfly valves, high-differential-pressure shutoff, high torque at low supply pressure
ConfigurationTwo cylinders in parallel driving one valve shaft, outputs combined through a linkage
Output combiningOutputs add only under synchronous conditions; size with the official selection tool
Suitable seriesLarge-bore scotch yoke, rack and pinion, heavy-duty piston
Main documentsNeles/Valmet 6B20EN and 6vb20en; HKC PA-25P R1; SMC SRT catalogue

Sources: Neles/Valmet official catalogues 6B20EN and 6vb20en; HKC official catalogue PA-25P R1; SMC official SRT series catalogue. Specific parallel schemes require manufacturer engineering confirmation.

Twin actuator illustration
Pneumatic actuator illustration, not the actual model; parameters subject to the official catalogue

II. Parallel Configuration Forms

FormStructural description
Coaxial twin cylindersTwo cylinders arranged symmetrically on either side of the shaft, torque combined on a common output shaft
Twin scotch yokeTwo scotch-yoke cylinders in parallel with linkages joining one yoke
Twin rack and pinionTwo rack-and-pinion units in parallel with a common output gear
Top-bottom arrangementLinear valves can use two actuators above and below driving one stem crossbeam
Linkage beamA rigid beam or linkage keeps both sides moving in step

The above is a general-structure reference, not a guaranteed value for any model; specific layout subject to the official catalogue and engineering drawings.

III. Synchronization and Load Points

PointDescription
Torque matchingBoth actuators should share model, supply pressure and spring configuration
Motion synchronizationCommon output shaft or rigid linkage prevents one side leading and creating internal force
Consistent deadbandBacklash differences between the two units can cause oscillation or binding
Air capacityTotal consumption is the sum of both units; enlarge piping and regulator capacity
Limit settingTravel limits set uniformly to actual valve open and closed positions
Maintenance isolationMechanically lock one unit before servicing so the other cannot move unexpectedly

Sources: Neles/Valmet official catalogue 6B20EN (selection rule: output torque not less than required valve torque; lifting eye bolts prohibited on twin-cylinder types); SMC official SRT series catalogue.

IV. Comparison with a Single Large Cylinder

ItemTwin actuatorsSingle large cylinder
Output torqueCombined output reaches higher torqueLimited by bore and supply pressure
SpaceLarger footprint and symmetrical mounting neededCompact
Air demandDoubled consumption; piping must be enlargedComparatively low
Synchronization riskRisk of out-of-step motion and internal forceNo synchronization issue
ReliabilityDegraded operation possible if one unit fails (configuration dependent)Single-point failure disables the valve
MaintenanceTwice the service pointsComparatively simple

The above is a general comparison, not a guaranteed value for any model; specifics subject to the official catalogue.

V. Selection Checks

Check itemDescription
Valve torqueSize to differential pressure and bore with margin
Supply pressureConfirm each unit delivers required output at minimum supply pressure
Acting formDouble-acting or spring return; size spring torque for worst case
Mounting interfaceISO 5211 or VDI/VDE 3845; verify common output shaft
AccessoriesPositioner, limit switches, handwheel and quick exhaust per unit
SafetySIL applications verified per IEC 61508 and IEC 61511; approvals subject to nameplate and certificate

Sources: Neles/Valmet official catalogue 6B20EN (Nelprof selection rule); safety standards IEC 61508 and IEC 61511; approvals subject to nameplate and certificate.

VI. Selection Guide and Common Models

Selection guide: First calculate required valve torque and minimum supply pressure to decide whether parallel actuators are really needed. Then use two identical units in the same configuration for synchronization. Next verify the common output shaft, linkage stiffness, air capacity and unified limits, and finally complete verification against SIL or ESD requirements. Never convert single-acting to double-acting and never use lifting eye bolts on twin-cylinder types. Where official confirmation is unavailable, refer to the official catalogue or nameplate.

Common models: Neles B1 series large-bore double-acting or spring return (6B20EN); Neles N1 heavy-duty scotch yoke for high-torque ESD; HKC ET series heavy rack plus scotch yoke (495 to 250000 Nm); SMC SRT rack and pinion series. These are public product series examples; specific parallel schemes require manufacturer engineering confirmation and the official catalogue.

If you are reviewing the mechanical interface between an actuator and a valve, please send us the acting form, mounting arrangement, connection and accessory requirements. We can review the model and installation details together against the official catalogue.

Orders & Inquiries

Baoman Industrial Technology (Chengdu) Co., Ltd
Tel: +86 028-60220547 | Email: info@bit-cd.com
Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry.