| Actuator Stem & Valve Stem Coupling - Locking Device Selection | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Release time:2026-11-27 23:56:05 | Views: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The connection between the actuator push rod and the valve stem is the key link for force transfer. Rigidity, alignment and locking reliability directly affect deadband, hysteresis and position stability. Common forms are threaded connection with lock nut, clamp-type connector, spline or key connection, and non-rotating split coupling. This article organizes connection forms, locking points and a checklist from a general-structure perspective; dimensions are subject to the official catalogue. I. Product Positioning
Sources: SAMSON official instructions EB 8097 EN and EB 8394 ZH; Emerson/Fisher official catalogue D102087X012; Flowserve official manual FCD LGENIM0105-16; interface standard ISO 5211.
II. Connection Forms
Sources: SAMSON official instruction EB 8394 ZH and spare parts list EB 8097 EN; Emerson/Fisher official catalogue D103295X012 (2052); Flowserve official manual FCD LGENIM0105-16. III. Locking and Anti-Loosening Points
Sources: SAMSON official instruction EB 8394 ZH; Flowserve official manual FCD LGENIM0105-16 (0.25 Nm follower bracket tightening torque is a catalogue example; confirm against the official manual). IV. Selection Checks
Sources: SAMSON official data sheets T 8097 EN and T 8048-21 EN, spare parts list EB 8097 EN; Emerson/Fisher official catalogue D102087X012. Example values are catalogue data; confirm by nameplate and order. V. Common Mistakes
Sources: SAMSON official instruction EB 8394 ZH; Flowserve official manual FCD LGENIM0105-16. VI. Selection Guide and Common ModelsSelection guide: First decide linear or rotary connection by valve motion, then check stem diameter, thread and actuator push rod interface. Next choose a clamp or non-rotating split coupling by deadband and thrust requirements, and finally lock to the official torque and recheck the position zero. Where official confirmation is unavailable, refer to the official catalogue or nameplate; do not guess parameters. Common models: SAMSON 3271/3277 actuators with M30 x 1.5 stem connection; SAMSON 3347 position 9 stem connector nut and position 10 lock nut; Fisher 2052 splined clamp connection; Fisher easy-Drive 200R square or splined shaft connection. These are public structural examples; ordering codes subject to the official catalogue and nameplate. If you are reviewing the mechanical interface between an actuator and a valve, please send us the acting form, mounting arrangement, connection and accessory requirements. We can review the model and installation details together against the official catalogue. Orders & InquiriesBaoman Industrial Technology (Chengdu) Co., LtdTel: +86 028-60220547 | Email: info@bit-cd.com Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry. |