Endress+Hauser PMC71 Digital Pressure Transmitter
1. Product Overview
Endress+Hauser PMC71 Digital Pressure Transmitter. The Endress+Hauser Cerabar S PMC71 is a digital pressure transmitter for absolute and gauge pressure in gases and liquids, using an oil free Ceraphire ceramic sensor in a dry measuring cell. Reference accuracy is 0.05 percent in the standard version and up to 0.025 percent in the Platinum version. The measuring cell covers 100 millibar to 40 bar relative or absolute, the vacuum resistance is zero millibar absolute, and the maximum overpressure limit is 60 bar. Process temperature extends from minus 40 to plus 150 degrees Celsius. Main wetted parts are Ceraphire ceramic, Alloy C, 316L, Monel and PVDF, and the process membrane is ceramic. Communication options include 4 to 20 milliamp HART, PROFIBUS PA and FOUNDATION Fieldbus. The model has been announced as phasing out, with the PMC71B available as its successor. ---
Official specifications are listed in the table below; values not published in official literature are not assumed.



2. Technical Description
Technical description: The Endress+Hauser Cerabar S PMC71 is a digital pressure transmitter for absolute and gauge pressure in gases and liquids, using an oil free Ceraphire ceramic sensor in a dry measuring cell. Reference accuracy is 0.05 percent in the standard version and up to 0.025 percent in the Platinum version. The measuring cell covers 100 millibar to 40 bar relative or absolute, the vacuum resistance is zero millibar absolute, and the maximum overpressure limit is 60 bar. Process temperature extends from minus 40 to plus 150 degrees Celsius. Main wetted parts are Ceraphire ceramic, Alloy C, 316L, Monel and PVDF, and the process membrane is ceramic. Communication options include 4 to 20 milliamp HART, PROFIBUS PA and FOUNDATION Fieldbus. The model has been announced as phasing out, with the PMC71B available as its successor. ---
3. Key Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Specification | The Endress+Hauser Cerabar S PMC71 is a digital pressure transmitter for absolute and gauge pressure in gases and liquids |
| Specification | using an oil free Ceraphire ceramic sensor in a dry measuring cell |
| Specification | Reference accuracy is 0.05 percent in the standard version and up to 0.025 percent in the Platinum version |
| Specification | The measuring cell covers 100 millibar to 40 bar relative or absolute |
| Specification | the vacuum resistance is zero millibar absolute |
| Specification | and the maximum overpressure limit is 60 bar |
| Specification | Process temperature extends from minus 40 to plus 150 degrees Celsius |
| Specification | Main wetted parts are Ceraphire ceramic |
| Specification | Alloy C |
| Specification | 316L |
| Specification | Monel and PVDF |
| Specification | and the process membrane is ceramic |
| Specification | Communication options include 4 to 20 milliamp HART |
| Specification | PROFIBUS PA and FOUNDATION Fieldbus |
| Specification | The model has been announced as phasing out |
| Specification | with the PMC71B available as its successor. --- |
4. Selection Quick Reference (Ordering Code by Position)
| Item | Description |
|---|---|
| Ordering and full model enumeration | Models covered: PMC71, PMP71, PMP75, PMC71B. For complete ordering codes and digit-by-digit definitions, refer to the official data sheet in the source section; verify with the manufacturer. |
5. Complete Model Enumeration
No other models in this series in this batch.
6. Related Models
No related models in this batch.
7. Common Spare Parts
| Spare part | Description |
|---|---|
| Seat / trim kit | By size and material; refer to the latest official literature; verify with the manufacturer |
| Stem packing / seal kit | By valve type and medium; verify with the manufacturer |
| Guide bushing | Wear part, by size; verify with the manufacturer |
| Gasket / O-ring kit | By body material and medium; verify with the manufacturer |
8. Accessories
| Accessory | Description |
|---|---|
| Pneumatic / electric actuator | Selected by torque and duty, with positioner |
| Valve positioner | 4-20 mA HART / fieldbus, by single/double acting and linear/rotary |
| Limit switch / position feedback | SPDT or NAMUR, by explosion protection and ingress rating |
| Filter regulator / air set | Stable air supply for pneumatic actuators, by port and flow |
9. Disclaimer
The information above is not guaranteed to remain current; changes may be made without prior notice. Please confirm the latest information at the time of inquiry. Certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources and Contact
We supply the above models, spare parts and accessories. For selection or supply inquiries, please contact: +86 028-60220547 | info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文
ENGLISH