Flowserve PMV PS / PM Intrinsically Safe Modular Switch Box
1. Product Overview
Flowserve PMV PS / PM Intrinsically Safe Modular Switch Box. The PMV PS/PM UltraSwitch is a modular limit switch box built around a lightweight, corrosion-resistant fiberglass-reinforced PA6/PA66 resin enclosure. It provides intrinsically safe, non-incendive and increased-safety certifications, IP66/Type 4X protection and a -40 to +80 deg C operating range. Up to four switch elements and an optional 4-20 mA transmitter or potentiometer can be fitted, and the unit mounts directly on rotary or linear actuators or serves as a solenoid junction box. Typical applications include chemical, petrochemical, municipal, wastewater and pharmaceutical services.
Official specifications are listed in the table below; values not published in official literature are not assumed.



2. Technical Description
Technical description: Protection IP66 / Type 4X (the brochure also states IP66/67, NEMA 4X); weight 1 kg (2.2 lb). Housing and cover are PA6/PA66 nylon reinforced with 25-33% glass fiber; shaft stainless steel; cam and spline nylon; terminal block Buchanan TBS series; internal brackets stainless or plated steel; fasteners stainless steel; UltraDome polycarbonate. Approvals: ATEX II 1G Ex ia IIC T4/T5/T6 Gb (NEMKO 11ATEX1065X), IECEx Ex ia IIC T4/T5/T6 Gb (NEM 11.0012X), ATEX II 2G Ex e mb IIC T5/T6 Gb (NEMKO 12ATEX1079X, IP66; T5 -40 to 80 deg C, T6 -40 to 60 deg C), FM intrinsically safe Class I Div.1 Groups A-D T5, FM non-incendive Class I Div.2 Groups A-D T6. Operating -40 to 80 deg C; switch quantity 0/2/4; analog output options 4-20 mA transmitter, 180 deg 4-20 mA transmitter or 0-1 kohm potentiometer; optional Viton O-ring.
3. Key Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Specification | Protection IP66 / Type 4X (the brochure also states IP66/67 |
| Specification | NEMA 4X) |
| Weight | weight 1 kg (2.2 lb) |
| Housing | Housing and cover are PA6/PA66 nylon reinforced with 25-33% glass fiber |
| Specification | shaft stainless steel |
| Specification | cam and spline nylon |
| Specification | terminal block Buchanan TBS series |
| Specification | internal brackets stainless or plated steel |
| Specification | fasteners stainless steel |
| Specification | UltraDome polycarbonate |
| Specification | Approvals: ATEX II 1G Ex ia IIC T4/T5/T6 Gb (NEMKO 11ATEX1065X) |
| Specification | IECEx Ex ia IIC T4/T5/T6 Gb (NEM 11.0012X) |
| Certification | ATEX II 2G Ex e mb IIC T5/T6 Gb (NEMKO 12ATEX1079X |
| Specification | IP66 |
| Specification | T5 -40 to 80 deg C |
| Specification | T6 -40 to 60 deg C) |
| Certification | FM intrinsically safe Class I Div.1 Groups A-D T5 |
| Certification | FM non-incendive Class I Div.2 Groups A-D T6 |
| Specification | Operating -40 to 80 deg C |
| Specification | switch quantity 0/2/4 |
| Specification | analog output options 4-20 mA transmitter |
| Specification | 180 deg 4-20 mA transmitter or 0-1 kohm potentiometer |
| Specification | optional Viton O-ring |
4. Selection Quick Reference (Ordering Code by Position)
| Item | Description |
|---|---|
| Ordering and full model enumeration | A brand label P; B shaft N NAMUR VDI/VDE 3845 / D double-D 1/4 in; C connection PS resin 1/2 NPT / PM resin M20x1.5 / PN 3/4 NPT / PG M25x1.5; D conduit count 1/2/3; E indicator 1 flat cover no indication / U standard UltraDome, with 90 deg, 180 deg, 120 deg on/off, black/yellow, white/blue and reverse viewing options; F switch count 0/2/4; G switch options; H certification 14 general / 15 ATEX ia / 21 IECEx ia / 22 ATEX e mb / 27 FM IS / 28 FM NI and CSA NI / 40, 60 multiple certifications; I analog output 0 none / T 4-20 mA / D 180 deg 4-20 mA / A 0-1 kohm; J wiring 0 / 3 Brad Harrison 7-pin / 4 Weidmuller / H heavy-duty terminals; K extra terminals 2/4/6/8; L special options 0 none / V Viton O-ring. |
5. Complete Model Enumeration
| Model | Description |
|---|---|
| Flowserve PMV F5 Limit Switch Box with 4-20 mA Feedback | Related model in this batch |
| Flowserve PMV WS / WM Intrinsically Safe Compact Switch Box | Related model in this batch |
| Flowserve PMV P5 / EP5 Analog Valve Positioner | Related model in this batch |
6. Related Models
| Related models | Brief description |
|---|---|
| Flowserve PMV F5 Limit Switch Box with 4-20 mA Feedback | Related model in this batch |
| Flowserve PMV WS / WM Intrinsically Safe Compact Switch Box | Related model in this batch |
| Flowserve PMV P5 / EP5 Analog Valve Positioner | Related model in this batch |
7. Common Spare Parts
| Spare part | Description |
|---|---|
| Seat / trim kit | By size and material; refer to the latest official literature; verify with the manufacturer |
| Stem packing / seal kit | By valve type and medium; verify with the manufacturer |
| Guide bushing | Wear part, by size; verify with the manufacturer |
| Gasket / O-ring kit | By body material and medium; verify with the manufacturer |
8. Accessories
| Accessory | Description |
|---|---|
| Pneumatic / electric actuator | Selected by torque and duty, with positioner |
| Valve positioner | 4-20 mA HART / fieldbus, by single/double acting and linear/rotary |
| Limit switch / position feedback | SPDT or NAMUR, by explosion protection and ingress rating |
| Filter regulator / air set | Stable air supply for pneumatic actuators, by port and flow |
9. Disclaimer
The information above is not guaranteed to remain current; changes may be made without prior notice. Please confirm the latest information at the time of inquiry. Certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources and Contact
We supply the above models, spare parts and accessories. For selection or supply inquiries, please contact: +86 028-60220547 | info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文