Details

1. Product Overview

Flowserve Argus EK71 End-Entry Floating Ball Valves. The Flowserve Argus EK71 is an end-entry floating ball valve with a one-piece forged body for oil and gas service, designed to prevent production or process leakage. It meets API 6D, ASME B16.34 and BS 5351, and its FCI 70-2 Class VI seat design can meet up to zero-leakage shutoff requirements.

Official specifications are listed in the table below; values not published in official literature are not assumed.

Source: Flowserve official Argus EK71 product pages and official Argus EK71 literature / IOM..

Above: product appearance / manufacturer literature image.

2. Technical Description

Technical description: A soft-seated floating ball design with blow-out-proof stem, bearing-supported stem and long-life dual stem seals keeps sealing components unloaded. Stem sealing complies with TA-Luft and EPA Method 21. The valve meets API 607 / ISO 10497 fire safety, ISO 15848 fugitive emissions, DIN EN ISO 17292 anti-static and PED 97/23/EC.

Source: Flowserve official Argus EK71 product pages and official Argus EK71 literature / IOM..

Source: Flowserve official Argus EK71 product pages and official Argus EK71 literature / IOM.

3. Main Technical Specifications

ParameterSpecification / Description
ParameterSpecification / Description
Size rangeDN 15-50 mm (DIN); NPS 1/2-2 in (ASME)
Pressure classPN 16-PN 100 (DIN); Class 150-600 (ASME)
Body materialOne-piece low-temperature forged carbon steel body (end-entry); exact material subject to the latest official data sheet; verify with the manufacturer
SeatSoft seated, FCI 70-2 Class VI seat
ConnectionFlanged; ASME B16.34, API 6D, PED 97/23/EC
Temperature-48 to +230 C (-54 to +446 F)
MediaOil and gas, downstream processing, midstream transmission, power (nuclear/conventional steam/geothermal/combined cycle)
OperationManual (lever / wing / spring return) or with actuator; limit switch, locking device, extended wrench and extended stem optional
StandardsASME B16.34, API 6D, PED 97/23/EC, API 607 / ISO 10497, ISO 15848, DIN EN ISO 17292
Source: Flowserve official Argus EK71 product pages and official Argus EK71 literature / IOM.

4. Selection Guide

ItemDescription
Ordering and full model enumerationSee the corresponding Chinese-language page and the official data sheet for complete ordering codes and digit-by-digit definitions
Source: Flowserve official Argus EK71 product pages and official Argus EK71 literature / IOM.

5. Complete Model Enumeration

ModelDescription
ASCO 210ASCO / Flowserve model in this batch
ASCO 327ASCO / Flowserve model in this batch
ASCO 551ASCO / Flowserve model in this batch
ASCO 316ASCO / Flowserve model in this batch
ASCO 353ASCO / Flowserve model in this batch
ASCO 320ASCO / Flowserve model in this batch
ASCO 215ASCO / Flowserve model in this batch
ASCO 314ASCO / Flowserve model in this batch
Flowserve EK71ASCO / Flowserve model in this batch
Flowserve McCANNA FloatingASCO / Flowserve model in this batch
Flowserve McCANNA Top EntryASCO / Flowserve model in this batch
Flowserve VW1ASCO / Flowserve model in this batch
Flowserve DBBASCO / Flowserve model in this batch

6. Related Models

Related modelsBrief description
501Related model in this batch; see the corresponding page
503Related model in this batch; see the corresponding page

7. Common Spare Parts

Spare partPart number / description
CoilBy series, approval and voltage; subject to the official data sheet
Seat / seals / diaphragmBy medium, temperature and valve type; subject to the official data sheet
Body repair kit / packingBy size and configuration; subject to the official spare parts list
Manual operator MO / bracketBy installation and control requirements
Other sparesSubject to the official spare parts list; verify with the manufacturer

8. Accessories

AccessoryDescription
Limit switch / feedback unitBy control system interface; subject to the official data sheet
Filter regulator / air preparationBy air supply conditions
NAMUR adapter / mounting bracketBy installation method
Explosion-proof coil / junction boxBy hazardous-area and approval requirements; subject to the official data sheet
Other accessoriesSubject to the official data sheet; verify with the manufacturer

9. Disclaimer

The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources & Contact

Source: Flowserve official Argus EK71 product pages and official Argus EK71 literature / IOM..

We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area