Masoneilan 51/52/53 Series Pneumatic Piston Actuators
1. Product Overview
Baker Hughes / Masoneilan 51 / 52 / 53 Series belongs to the Baker Hughes Masoneilan valve, actuator and instrument product line. The 51/52/53 Series are Baker Hughes Masoneilan pneumatic piston cylinder actuators for duties beyond the capability of conventional spring-diaphragm actuators, providing high thrust and high dynamic stiffness for throttling and on/off control. Type 51 is double-acting with no spring and an optional integral air reservoir for fail action; Type 52 is single-acting spring-return with air-to-extend, and Type 53 is single-acting spring-return with air-to-retract.
Key official parameters are listed in the specification table below; type, materials, performance and typical applications follow official literature.
Specific values, interfaces and ordering codes are subject to the latest official data sheet; verify with the manufacturer.



2. Technical Description
Type / positioning: The 51/52/53 Series are Baker Hughes Masoneilan pneumatic piston cylinder actuators for duties beyond the capability of conventional spring-diaphragm actuators, providing high thrust and high dynamic stiffness for throttling and on/off control. Type 51 is double-acting with no spring and an optional integral air reservoir for fail action; Type 52 is single-acting spring-return with air-to-extend, and Type 53 is single-acting spring-return with air-to-retract.
Key technology: construction, materials, performance and application notes are listed in the specification table.
Selection note: Use the 51/52/53 series where higher thrust or longer stroke than a spring-diaphragm actuator is required; size the cylinder 12-46 from the valve thrust and stroke. The fail-safe direction sets the model: double-acting with no spring plus a reservoir for Type 51, or spring-return Type 52 (air-to-close, fail-open) or Type 53 (air-to-open, fail-close). Choose the standard spring range, 10-25 / 20-40 / 25-50 psi, to match the control signal pressure. For very fast response or large cylinder volume, reduce the cylinder volume to use its high stiffness; for loss-of-air manual operation select a handwheel, hand gear or hydraulic operator.
Source: Parameters per Baker Hughes / Masoneilan official product pages, official data sheets and official manuals.
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Item | Specification / Description |
| Type / positioning | Pneumatic piston cylinder actuators; high thrust and dynamic stiffness; throttling and on/off control |
| Model configurations | 51: double-acting, single or double piston, no spring, optional integral reservoir; 52: single-acting, air-to-extend spring-return; 53: single-acting, air-to-retract spring-return |
| Sizes and max stroke | Type 51: size 12 (4 in/101 mm), 16 and 20 (30 in/762 mm), 24/28/32 (12 in/304 mm), 40/46 (6 in/152 mm); Types 52/53: 12 (4 in/101 mm), 16/20 (6 in/152 mm) |
| Standard spring range (52/53) | 10-25 psi (0.07-0.17 MPa), 20-40 psi (0.14-0.28 MPa), 25-50 psi (0.17-0.34 MPa) |
| Thrust / effective area | Varies with cylinder size 12-46 and single or double piston construction; see official thrust and effective-area tables; subject to the latest official data sheet; verify with the manufacturer |
| Construction features | Heavy internal guidance and support; small cylinder volume and fast response; spring cartridge can be safely pre-compressed and reversed in the field; piston in a separate cylinder chamber for easy dynamic seal replacement; heavy stem guidance reduces wear and friction |
| Optional accessories | Integral or external air reservoirs for fail action on double-acting units, handwheel, hand gear or hydraulic manual operators, travel stops, low- and high-temperature versions, stainless steel fasteners, steel yokes |
| Approvals / compliance | EU Pressure Equipment Directive (PED) and ATEX 2014/34/EU, II 2 GD TX |
| Typical applications | Large valves, long strokes, high pressure drop and tight shutoff; turbines, condensers, cooling towers, reactor and turbine buildings, distillation, hydroprocessing, cracking, separation, pipelines and liquefaction |
4. Selection Guide
Selection sequence: Duty & process -> Type & construction -> Selection note -> Material & compliance -> Documentation check.
| Step | Item | Key point |
|---|---|---|
| 1 | Duty & process | Define service, fluid, pressure drop and temperature |
| 2 | Type & construction | Choose valve, actuator or instrument type from official literature |
| 3 | Selection note | Use the 51/52/53 series where higher thrust or longer stroke than a spring-diaphragm actuator is required; size the cylinder 12-46 from the valve thrust and stroke. The fail-safe direction sets the model: double-acting with no spring plus a reservoir for Type 51, or spring-return Type 52 (air-to-close, fail-open) or Type 53 (air-to-open, fail-close). Choose the standard spring range, 10-25 / 20-40 / 25-50 psi, to match the control signal pressure. For very fast response or large cylinder volume, reduce the cylinder volume to use its high stiffness; for loss-of-air manual operation select a handwheel, hand gear or hydraulic operator. |
| 4 | Material & compliance | Check body, trim and approvals for the service condition |
| 5 | Documentation check | Verify all parameters against the latest official data sheet |
Boundary note: Use the 51/52/53 series where higher thrust or longer stroke than a spring-diaphragm actuator is required; size the cylinder 12-46 from the valve thrust and stroke. The fail-safe direction sets the model: double-acting with no spring plus a reservoir for Type 51, or spring-return Type 52 (air-to-close, fail-open) or Type 53 (air-to-open, fail-close). Choose the standard spring range, 10-25 / 20-40 / 25-50 psi, to match the control signal pressure. For very fast response or large cylinder volume, reduce the cylinder volume to use its high stiffness; for loss-of-air manual operation select a handwheel, hand gear or hydraulic operator. Limit values are subject to the latest official data sheet; verify with the manufacturer.
5. Complete Model Enumeration
| Related / same series | Category | Note |
|---|---|---|
| BR200 / BR400 | Baker Hughes / Masoneilan valve, actuator or instrument | Same batch (CN347) |
| 4411 | Baker Hughes / Masoneilan valve, actuator or instrument | Same batch (CN352) |
| 74000 Series | Baker Hughes / Masoneilan valve, actuator or instrument | Same batch (CN401) |
| 75000 Series | Baker Hughes / Masoneilan valve, actuator or instrument | Same batch (CN402) |
| 77000 / 77003 Series | Baker Hughes / Masoneilan valve, actuator or instrument | Same batch (CN403) |
| 84000 Series SteamForm | Baker Hughes / Masoneilan valve, actuator or instrument | Same batch (CN404) |
| 12400 Series | Baker Hughes / Masoneilan valve, actuator or instrument | Same batch (CN405) |
| 12800 Series | Baker Hughes / Masoneilan valve, actuator or instrument | Same batch (CN406) |
| 51 / 52 / 53 Series | Baker Hughes / Masoneilan valve, actuator or instrument | This page (CN407) |
| 87 / 88 Series | Baker Hughes / Masoneilan valve, actuator or instrument | Same batch (CN408) |
6. Related Models
| Related models | Brief description |
|---|---|
| 74000 Series (CN401) | Heavy oil process valve |
| 87/88 Actuators (CN408) | Multi-spring diaphragm actuators |
7. Common Spare Parts
| Spare part | Part number / description |
|---|---|
| Diaphragm / seal kit | Model-specific; per official literature |
| Valve plug / seat set | Model-specific; per official literature |
| Packing / wiper set | Model-specific; per official literature |
| Spring / spring cartridge | Model-specific; per official literature |
| Filter element | Model-specific; per official literature |
| Other spares | Model-specific; per official literature; verify with the manufacturer |
8. Accessories
| Accessory | Description |
|---|---|
| Positioner / controller | Model-specific; per official literature |
| Handwheel / manual operator | Model-specific; per official literature |
| Air reservoir / booster relay | Model-specific; per official literature |
| Flange / connection kit | Model-specific; per official literature |
| Other accessories | Model-specific; per official literature; verify with the manufacturer |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China