INFICON PGE500-RS485/Analog Pirani Vacuum Gauge with OLED Display
1. Product Overview
INFICON PGE500-RS485/Analog belongs to the INFICON vacuum measurement product line. PGE500 RS485/Analog is an INFICON enhanced Pirani gauge using convection-enhanced technology, with an OLED display and integrated keypad, RS485/RS232 digital interfaces and four selectable analog outputs.
Key official parameters are listed in the specification table below; measuring principle, range, output signal and typical applications follow INFICON official literature.
Specific ranges, flange interfaces and ordering codes are subject to the latest official data sheet; verify with the manufacturer.



2. Technical Description
Type / positioning: PGE500 RS485/Analog is an INFICON enhanced Pirani gauge using convection-enhanced technology, with an OLED display and integrated keypad, RS485/RS232 digital interfaces and four selectable analog outputs.
Key technology: sensor principle, range, accuracy and output signal are listed in the specification table.
Selection note: Select for RS485/analog-integrated enhanced Pirani measurement; configure flange and output signals per official catalogue.
Source: Parameters per INFICON official product catalogue 2026 and official literature.
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Item | Specification / Description |
| Sensor / principle | Digital convection-enhanced Pirani, gold-plated tungsten filament |
| Measurement range | 1.3x10^-4 to 1333 mbar (1x10^-4 to 1000 Torr) |
| Accuracy (N2) | By range segments (per official literature) |
| Resolution | 0.1x10^-3 mbar |
| Display | Bright digital OLED display with keypad |
| Output signals | RS485/RS232 digital interfaces; four selectable analog outputs (3 user-selectable + 1 default) |
| Setpoints | Two setpoints |
| Features | Higher accuracy near atmosphere; factory-set or keypad-selected output signals |
| Typical applications | Foreline pressure measurement, general low to high vacuum control |
| Ordering no. | 352-525 (per official catalogue p. A87) |
4. Selection Guide
Selection sequence: Range & process -> Interface & signal -> Selection note -> Material & protection -> Ordering check.
| Step | Item | Key point |
|---|---|---|
| 1 | Range & process | Define sensor type by required vacuum range and process gas |
| 2 | Interface & signal | Check flange, output signal and communication (analog/RS485/DeviceNet/EtherCAT) |
| 3 | Selection note | Select for RS485/analog-integrated enhanced Pirani measurement; configure flange and output signals per official catalogue. |
| 4 | Material & protection | Use ceramic coating/platinum filament for corrosive service per official literature |
| 5 | Ordering check | Verify ordering codes against the official catalogue coding table |
Boundary note: Select for RS485/analog-integrated enhanced Pirani measurement; configure flange and output signals per official catalogue. Limit values are subject to the latest official literature; verify with the manufacturer.
5. Complete Model Enumeration
| Related / same series | Category | Note |
|---|---|---|
| Pilot Plus | INFICON vacuum gauge / equipment | Same batch (CN1758) |
| Wey-TEK Pro | INFICON vacuum gauge / equipment | Same batch (CN1759) |
| Vortex Dual | INFICON vacuum gauge / equipment | Same batch (CN1760) |
| QS5 | INFICON vacuum gauge / equipment | Same batch (CN1761) |
| CDG015D | INFICON vacuum gauge / equipment | Same batch (CN1762) |
| Trigon BAG552 | INFICON vacuum gauge / equipment | Same batch (CN1763) |
| Trigon BCG552 | INFICON vacuum gauge / equipment | Same batch (CN1764) |
| Trigon BPG552 | INFICON vacuum gauge / equipment | Same batch (CN1765) |
| PSG55x | INFICON vacuum gauge / equipment | Same batch (CN1766) |
| PCG55x | INFICON vacuum gauge / equipment | Same batch (CN1768) |
| Gemini MxG5xx | INFICON vacuum gauge / equipment | Same batch (CN1769) |
| MPG40X | INFICON vacuum gauge / equipment | Same batch (CN1770) |
| MAG470 | INFICON vacuum gauge / equipment | Same batch (CN1771) |
| OPG550 | INFICON vacuum gauge / equipment | Same batch (CN1772) |
| BAG402 | INFICON vacuum gauge / equipment | Same batch (CN1773) |
| PBR 260 | INFICON vacuum gauge / equipment | Same batch (CN1774) |
| BPG400 | INFICON vacuum gauge / equipment | Same batch (CN1775) |
| BPG402-Sx | INFICON vacuum gauge / equipment | Same batch (CN1776) |
| BCG450 | INFICON vacuum gauge / equipment | Same batch (CN1777) |
| HPG400 | INFICON vacuum gauge / equipment | Same batch (CN1778) |
| PGE300 | INFICON vacuum gauge / equipment | Same batch (CN1779) |
| PGE500-DeviceNet | INFICON vacuum gauge / equipment | Same batch (CN1780) |
| PGE500-RS485/Analog | INFICON vacuum gauge / equipment | This page (CN1781) |
| PPG550 | INFICON vacuum gauge / equipment | Same batch (CN1782) |
| PPG570 | INFICON vacuum gauge / equipment | Same batch (CN1783) |
| BAG302 | INFICON vacuum gauge / equipment | Same batch (CN1784) |
6. Related Models
| Related models | Brief description |
|---|---|
| PGE500-DeviceNet (CN1780) | DeviceNet version |
| PGE300 (CN1779) | Economical enhanced Pirani |
7. Common Spare Parts
| Spare part | Part number / description |
|---|---|
| Replacement sensor / filament | Model-specific (e.g. BAG302 iridium filament), per official spare parts list |
| Filter / pre-filter | Model-specific (e.g. Pilot Plus 710-701-G1), per official literature |
| Cable / connector | Per output signal, per official literature |
| Calibration chip | Removable calibration data chip (e.g. Trigon series), per official literature |
| Other spares | Per official spare parts list; verify with manufacturer |
8. Accessories
| Accessory | Description |
|---|---|
| Gauge controller / display unit | For passive gauge heads (e.g. VGC083/VGC031), model-specific |
| Flange / fitting | KF/NW/ISO/VCR/flared, per model and interface |
| Setpoint relay module | Model-specific, per official literature |
| Communication gateway / bus interface | RS485/DeviceNet/EtherCAT per system integration |
| Other accessories | Per official data sheet; verify with manufacturer |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文
ENGLISH