Home » Products » INFICON
INFICON PGE500-RS485/Analog Pirani Vacuum Gauge with OLED Display
INFICON PGE500-RS485/Analog Pirani Vacuum Gauge with OLED Display
INFICON PGE500-RS485/Analog Pirani Vacuum Gauge with OLED Display

INFICON PGE500-RS485/Analog Pirani Vacuum Gauge with OLED Display

Details

1. Product Overview

INFICON PGE500-RS485/Analog belongs to the INFICON vacuum measurement product line. PGE500 RS485/Analog is an INFICON enhanced Pirani gauge using convection-enhanced technology, with an OLED display and integrated keypad, RS485/RS232 digital interfaces and four selectable analog outputs.

Key official parameters are listed in the specification table below; measuring principle, range, output signal and typical applications follow INFICON official literature.

Specific ranges, flange interfaces and ordering codes are subject to the latest official data sheet; verify with the manufacturer.

Above: product appearance / manufacturer literature image.

2. Technical Description

Type / positioning: PGE500 RS485/Analog is an INFICON enhanced Pirani gauge using convection-enhanced technology, with an OLED display and integrated keypad, RS485/RS232 digital interfaces and four selectable analog outputs.

Key technology: sensor principle, range, accuracy and output signal are listed in the specification table.

Selection note: Select for RS485/analog-integrated enhanced Pirani measurement; configure flange and output signals per official catalogue.

Source: Parameters per INFICON official product catalogue 2026 and official literature.

Source: INFICON official product catalogue 2026 and official literature

3. Main Technical Specifications

ParameterSpecification / Description
ItemSpecification / Description
Sensor / principleDigital convection-enhanced Pirani, gold-plated tungsten filament
Measurement range1.3x10^-4 to 1333 mbar (1x10^-4 to 1000 Torr)
Accuracy (N2)By range segments (per official literature)
Resolution0.1x10^-3 mbar
DisplayBright digital OLED display with keypad
Output signalsRS485/RS232 digital interfaces; four selectable analog outputs (3 user-selectable + 1 default)
SetpointsTwo setpoints
FeaturesHigher accuracy near atmosphere; factory-set or keypad-selected output signals
Typical applicationsForeline pressure measurement, general low to high vacuum control
Ordering no.352-525 (per official catalogue p. A87)
Source: INFICON official product catalogue 2026 and official literature

4. Selection Guide

Selection sequence: Range & process -> Interface & signal -> Selection note -> Material & protection -> Ordering check.

StepItemKey point
1Range & processDefine sensor type by required vacuum range and process gas
2Interface & signalCheck flange, output signal and communication (analog/RS485/DeviceNet/EtherCAT)
3Selection noteSelect for RS485/analog-integrated enhanced Pirani measurement; configure flange and output signals per official catalogue.
4Material & protectionUse ceramic coating/platinum filament for corrosive service per official literature
5Ordering checkVerify ordering codes against the official catalogue coding table

Boundary note: Select for RS485/analog-integrated enhanced Pirani measurement; configure flange and output signals per official catalogue. Limit values are subject to the latest official literature; verify with the manufacturer.

Source: INFICON official product catalogue 2026 and official literature

5. Complete Model Enumeration

Related / same seriesCategoryNote
Pilot PlusINFICON vacuum gauge / equipmentSame batch (CN1758)
Wey-TEK ProINFICON vacuum gauge / equipmentSame batch (CN1759)
Vortex DualINFICON vacuum gauge / equipmentSame batch (CN1760)
QS5INFICON vacuum gauge / equipmentSame batch (CN1761)
CDG015DINFICON vacuum gauge / equipmentSame batch (CN1762)
Trigon BAG552INFICON vacuum gauge / equipmentSame batch (CN1763)
Trigon BCG552INFICON vacuum gauge / equipmentSame batch (CN1764)
Trigon BPG552INFICON vacuum gauge / equipmentSame batch (CN1765)
PSG55xINFICON vacuum gauge / equipmentSame batch (CN1766)
PCG55xINFICON vacuum gauge / equipmentSame batch (CN1768)
Gemini MxG5xxINFICON vacuum gauge / equipmentSame batch (CN1769)
MPG40XINFICON vacuum gauge / equipmentSame batch (CN1770)
MAG470INFICON vacuum gauge / equipmentSame batch (CN1771)
OPG550INFICON vacuum gauge / equipmentSame batch (CN1772)
BAG402INFICON vacuum gauge / equipmentSame batch (CN1773)
PBR 260INFICON vacuum gauge / equipmentSame batch (CN1774)
BPG400INFICON vacuum gauge / equipmentSame batch (CN1775)
BPG402-SxINFICON vacuum gauge / equipmentSame batch (CN1776)
BCG450INFICON vacuum gauge / equipmentSame batch (CN1777)
HPG400INFICON vacuum gauge / equipmentSame batch (CN1778)
PGE300INFICON vacuum gauge / equipmentSame batch (CN1779)
PGE500-DeviceNetINFICON vacuum gauge / equipmentSame batch (CN1780)
PGE500-RS485/AnalogINFICON vacuum gauge / equipmentThis page (CN1781)
PPG550INFICON vacuum gauge / equipmentSame batch (CN1782)
PPG570INFICON vacuum gauge / equipmentSame batch (CN1783)
BAG302INFICON vacuum gauge / equipmentSame batch (CN1784)

6. Related Models

Related modelsBrief description
PGE500-DeviceNet (CN1780)DeviceNet version
PGE300 (CN1779)Economical enhanced Pirani

7. Common Spare Parts

Spare partPart number / description
Replacement sensor / filamentModel-specific (e.g. BAG302 iridium filament), per official spare parts list
Filter / pre-filterModel-specific (e.g. Pilot Plus 710-701-G1), per official literature
Cable / connectorPer output signal, per official literature
Calibration chipRemovable calibration data chip (e.g. Trigon series), per official literature
Other sparesPer official spare parts list; verify with manufacturer

8. Accessories

AccessoryDescription
Gauge controller / display unitFor passive gauge heads (e.g. VGC083/VGC031), model-specific
Flange / fittingKF/NW/ISO/VCR/flared, per model and interface
Setpoint relay moduleModel-specific, per official literature
Communication gateway / bus interfaceRS485/DeviceNet/EtherCAT per system integration
Other accessoriesPer official data sheet; verify with manufacturer

9. Disclaimer

The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources & Contact

Source: INFICON official product catalogue 2026 and official literature.

We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China