INFICON FLUE-MATE Multi-Function Combustion Efficiency Analyzer with LCD
1. Product Overview
INFICON FLUE-MATE belongs to the INFICON leak detection and gas analysis product line. The FLUE-MATE is an INFICON multi-function combustion efficiency analyzer integrating flue-gas analysis, a pressure gauge and a thermometer for ambient/flue CO testing, damaged heat-exchanger testing and draft analysis. A backlit LCD shows efficiency, O2, CO2, CO and flue temperature on one screen.
Key official parameters are listed in the specification table below; detection media and typical applications follow INFICON official literature.
Specific ranges, approvals and ordering codes are subject to the latest official data sheet; verify with the manufacturer.



2. Technical Description
Type / positioning: The FLUE-MATE is an INFICON multi-function combustion efficiency analyzer integrating flue-gas analysis, a pressure gauge and a thermometer for ambient/flue CO testing, damaged heat-exchanger testing and draft analysis. A backlit LCD shows efficiency, O2, CO2, CO and flue temperature on one screen.
Key technology: sensor technology, sensitivity, detectable gases and power are listed in the specification table.
Selection note: Select for boiler/burner commissioning and combustion efficiency analysis (not leak detection); choose the Bluetooth printer version for on-site reports.
Source: Parameters per INFICON official product catalogue 2026 and official service tool literature.
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Item | Specification / Description |
| Type | Combustion efficiency analyzer (not a leak detector) |
| O2 | 0-25.0% vol; resolution 0.1% vol, accuracy ±0.2% vol |
| CO | 0-4000 ppm; resolution 1 ppm, accuracy ±20 ppm or ±5% of reading |
| CO2 (calculated) | 0-99.9% vol |
| Flue temperature | -20.0 to 800.0 C |
| Ambient temperature | -20.0 to 120.0 C |
| Pressure | -99.5 to 199.1 mbar |
| Efficiency (calculated) | 0-120% |
| Sensors | Field-replaceable O2 sensor; high H2-interference immunity CO sensor with NOx filter; auto-protection; NOx upgrade available |
| Fuels | 15 programmable fuels (natural gas, propane, butane, diesel, fuel oil, biogas, wood, coal, etc.) |
| Power / runtime | Rechargeable Li-ion battery; approx. 8 h |
| Probe | 1.5 m (5 ft) dual-hose flue probe |
| Weight | 350 g |
| Display | Backlit LCD; companion app generates reports |
| Approvals | Per official literature |
| Warranty | One year (China official channel) |
| Ordering no. | 502-202-G11 (base); 502-203-G11 (with Bluetooth printer) |
4. Selection Guide
Selection sequence: Detectant confirmation -> Sensitivity & approvals -> Selection note -> Power & accessories -> Ordering check.
| Step | Item | Key point |
|---|---|---|
| 1 | Detectant confirmation | Identify refrigerant / combustible gas / CO / ultrasonic leak to select instrument type |
| 2 | Sensitivity & approvals | Check minimum sensitivity, target gas and area approvals (A2L / intrinsic safety / EN14624) |
| 3 | Selection note | Select for boiler/burner commissioning and combustion efficiency analysis (not leak detection); choose the Bluetooth printer version for on-site reports. |
| 4 | Power & accessories | Select battery version, sensor and accessories per official literature |
| 5 | Ordering check | Verify ordering codes against the official data sheet |
Boundary note: Select for boiler/burner commissioning and combustion efficiency analysis (not leak detection); choose the Bluetooth printer version for on-site reports. Limit values are subject to the latest official literature; verify with the manufacturer.
5. Complete Model Enumeration
| Related / same series | Category | Note |
|---|---|---|
| D-TEK 3 | INFICON leak detector / gas analyzer | Same batch (CN1751) |
| D-TEK Pro | INFICON leak detector / gas analyzer | Same batch (CN1752) |
| TEK-Mate | INFICON leak detector / gas analyzer | Same batch (CN1753) |
| Whisper | INFICON leak detector / gas analyzer | Same batch (CN1754) |
| GAS-MATE | INFICON leak detector / gas analyzer | Same batch (CN1755) |
| FLUE-MATE | INFICON leak detector / gas analyzer | This page (CN1756) |
| CO Check | INFICON leak detector / gas analyzer | Same batch (CN1757) |
6. Related Models
| Related models | Brief description |
|---|---|
| CO Check (CN1757) | Ambient carbon monoxide meter |
| GAS-MATE (CN1755) | Combustible gas leak detector |
7. Common Spare Parts
| Spare part | Part number / description |
|---|---|
| Replacement sensor | Model-specific (e.g. GAS-MATE 706-700-G1, TEK-Mate 703-020-G1), per official literature |
| Filter cartridge | Model-specific, per official literature |
| Battery / battery pack | Model-specific, per official literature |
| Carrying case / holster | Model-specific, per official literature |
| Reference leak (calibration) | TEK-Check R134a 703-080-G10 etc., per official literature |
8. Accessories
| Accessory | Description |
|---|---|
| Headphones / earbuds | Audio alarm monitoring, model-specific |
| Ultrasonic transmitter | For Whisper sealed-enclosure checks (711-600-G1) |
| Charger / power adapter | Per battery version, per official literature |
| Calibration reference leak | By refrigerant type |
| Other accessories | Per official data sheet; verify with manufacturer |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文
ENGLISH