KROHNE OPTIMASS 2400 Coriolis Mass Flowmeter - Dual-tube, low pressure drop, lar
1. Product Overview
The KROHNE OPTIMASS 2400 is a Coriolis mass flowmeter that measures mass flow, volumetric flow, density and temperature directly, without media conversion factors. Nominal bore: DN100-400.
It is intended for liquids (large flow). Key design: Dual-tube, low pressure drop, large bore. Typical applications: pipelines, liquid storage and transfer, large-flow process metering.
Accuracy, pressure and temperature limits are not fully published here; refer to the official datasheet; verify with the manufacturer.



2. Technical Description
Measuring principle: Coriolis force; direct mass-flow measurement with density and temperature outputs.
Nominal bore: DN100-400.
Media: Liquids (large flow).
Design: Dual-tube, low pressure drop, large bore.
Outputs and communication: 4-20 mA / HART / FOUNDATION Fieldbus / Profibus PA / Modbus, depending on configuration; refer to the official datasheet; verify with the manufacturer.
Typical applications: Pipelines, liquid storage and transfer, large-flow process metering.
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Product type | Coriolis mass flowmeter |
| Model | KROHNE OPTIMASS 2400 |
| Nominal bore | DN100-400 |
| Measured media | Liquids (large flow) |
| Outputs / communication | 4-20 mA / HART / FF / Profibus PA / Modbus (per configuration) |
| Accuracy | refer to the official datasheet; verify with the manufacturer |
| Pressure rating | refer to the official datasheet; verify with the manufacturer |
| Temperature range | refer to the official datasheet; verify with the manufacturer |
| Design features | Dual-tube, low pressure drop, large bore |
| Typical applications | Pipelines, liquid storage and transfer, large-flow process metering |
| Ordering | Refer to the official datasheet; verify with the manufacturer |
4. Selection Guide
Selection sequence: Media check -> Bore check -> Accuracy and pressure -> Communication -> Materials and connections.
| Step | Item | Key point |
|---|---|---|
| 1 | Media check | Confirm liquid / gas / two-phase flow and whether EGM is required |
| 2 | Bore check | Bore DN100-400; verify against process flow and pressure drop |
| 3 | Accuracy and pressure | Verify accuracy and pressure class against the official datasheet |
| 4 | Communication | Select HART / FF / Profibus PA / Modbus and the matching MFC converter |
| 5 | Materials and connections | Confirm wetted materials and process connections; verify with the manufacturer |
Boundary: Pipelines, liquid storage and transfer, large-flow process metering. Limits and ordering codes: refer to the official datasheet; verify with the manufacturer.
5. Complete Model Enumeration
| Model | Description | Note |
|---|---|---|
| OPTIMASS / OPTIGAS / OPTIBATCH | Coriolis mass flowmeter | See the CN counterpart page |
| OPTIMASS 5400 | Lightweight Coriolis mass flowmeter, DN10-100 | Companion model (from CN1736) |
| OPTIMASS 6400 | Dual bent-tube mass flowmeter, DN10-300 | Companion model (from CN1737) |
| OPTIMASS 2400 | Large-bore liquid mass flowmeter, DN100-400 | This model (EN page from CN1738) |
| OPTIMASS 7400 | Food-grade hygienic mass flowmeter, DN10-100 | Companion model (from CN1739) |
| OPTIMASS 1400 | Dual straight-tube mass flowmeter, DN15-100 | Companion model (from CN1740) |
| OPTIMASS 3400 | Z-shaped single-tube mass flowmeter with EGM, from DN15 | Companion model (from CN1741) |
| OPTIMASS 7010 | Single straight-tube corrosion-resistant mass flowmeter | Companion model (from CN1742) |
| OPTIMASS 3010 | Single bent-tube small-bore mass flowmeter, DN15 threaded | Companion model (from CN1743) |
| OPTIMASS 1010 | Basic Coriolis mass flowmeter, DN15-100 | Companion model (from CN1744) |
| OPTIBATCH 4021 | Hygienic batching mass flowmeter, stainless dual bent tube | Companion model (from CN1745) |
| OPTIGAS 4010 | Dual bent-tube gas mass flowmeter, 3/4 NPT | Companion model (from CN1746) |
6. Related Models
| Related models | Note |
|---|---|
| OPTIMASS 3400 | Z-shaped single tube with EGM for wet gas and high pressure |
| OPTIMASS 6400 | Dual bent tube high accuracy, DN10-300 |
| MFC series converters | MFC 400 / 300 / 050 selected by protocol |
7. Common Spare Parts
| Spare part | Part number / note |
|---|---|
| Measuring tube / sensor assembly | See the official spare-parts list; verify with the manufacturer |
| MFC converter spares | See the official spare-parts list; verify with the manufacturer |
| Process-connection seals | See the official spare-parts list; verify with the manufacturer |
| Electronic module / display board | See the official spare-parts list; verify with the manufacturer |
| Calibration and verification kit | See the official spare-parts list; verify with the manufacturer |
8. Accessories
| Accessory | Description |
|---|---|
| MFC 400 signal converter | Full protocol (HART / FF / Profibus PA / Modbus), supports density and temperature |
| MFC 300 signal converter | General purpose, 4-20 mA / HART |
| MFC 050 / 051 converter | Compact, economical, 4-20 mA / HART |
| Mounting bracket / flange kit | Selected by bore and process connection; verify with the manufacturer |
| Other accessories | Refer to the official datasheet |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文