Elster RABO Gas Rotary Flowmeter DN32-DN150
1. Product Overview
The Honeywell RABO. Gas rotary (roots) flowmeter, DN32-DN150.
Key technical information is given in the table and Technical Description below. Values not published in official literature are directed to the official data sheet; refer to the official data sheet; verify with the manufacturer.
This page presents only official product positioning and technical data; certification and production status should be verified with the manufacturer.



2. Technical Description
Type: Gas rotary (roots) flowmeter, DN32-DN150.
Type: Gas rotary (positive displacement) flowmeter
Size: DN32, 40, 50, 80, 100, 150 (1.25 in to 6 in)
Meter sizes / Qmax: G16 25 m3/h through G400 650 m3/h
Flow range: 0.6-650 m3/h, turndown up to 1:160 (official brochure)
Pressure class: PN10/16 and Class 150 (ASME B16.5); max operating pressure 20 bar
Temperature: Gas / ambient -25 to +70 deg C
Body: Aluminium or spheroidal cast iron
Protection: IP67 (outdoor)
Accuracy: Accuracy class AC1.0; reproducibility <0.1%
Index: S1V standard; optional S1D absolute encoder / dual index
Pulse output: LF (reed / Wiegand), HF NAMUR (refer to the official data sheet; verify with the manufacturer)
Approvals: MID DE-12-MI002-PTB001; PED CE-0085CN0022; ATEX zone 1
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Type / model | Honeywell Elster RABO |
| Type | Gas rotary (positive displacement) flowmeter |
| Size | DN32, 40, 50, 80, 100, 150 (1.25 in to 6 in) |
| Meter sizes / Qmax | G16 25 m3/h through G400 650 m3/h |
| Flow range | 0.6-650 m3/h, turndown up to 1:160 (official brochure) |
| Pressure class | PN10/16 and Class 150 (ASME B16.5); max operating pressure 20 bar |
| Temperature | Gas / ambient -25 to +70 deg C |
| Body | Aluminium or spheroidal cast iron |
| Protection | IP67 (outdoor) |
| Accuracy | Accuracy class AC1.0; reproducibility <0.1% |
| Index | S1V standard; optional S1D absolute encoder / dual index |
| Pulse output | LF (reed / Wiegand), HF NAMUR (refer to the official data sheet; verify with the manufacturer) |
| Approvals | MID DE-12-MI002-PTB001; PED CE-0085CN0022; ATEX zone 1 |
| Ordering | refer to the official data sheet; verify with the manufacturer |
4. Selection Guide
Selection sequence: Application -> Parameter check -> Selection point -> Accessories -> Approvals.
| Step | Item | Key point |
|---|---|---|
| 1 | Application | Gas rotary (roots) flowmeter, DN32-DN150 |
| 2 | Parameter check | Verify size, pressure, flow and accuracy against the official data sheet |
| 3 | Selection point | For compact DN32-DN150 metering with no inlet straight run; refer to the official data sheet; verify with the manufacturer. |
| 4 | Accessories | Configure volume correction / communication / sensors as required; refer to the official data sheet; verify with the manufacturer. |
| 5 | Approvals | Certification status: refer to the official data sheet; verify with the manufacturer. |
Boundary: For compact DN32-DN150 metering with no inlet straight run; refer to the official data sheet; verify with the manufacturer. Limits: refer to the official data sheet; verify with the manufacturer.
5. Complete Model Enumeration
| Model | Type | Note |
|---|---|---|
| Elster 5020 | Honeywell Elster regulation / metering device | Companion model (from CN1696) |
| J125B | Honeywell Elster regulation / metering device | Companion model (from CN1697) |
| EK205 | Honeywell Elster regulation / metering device | Companion model (from CN1698) |
| EK280 | Honeywell Elster regulation / metering device | Companion model (from CN1699) |
| FC1 | Honeywell Elster regulation / metering device | Companion model (from CN1700) |
| IRM-3 DUO | Honeywell Elster regulation / metering device | Companion model (from CN1721) |
| Q.Sonic MAX | Honeywell Elster regulation / metering device | Companion model (from CN1722) |
| Q.Sonic PLUS | Honeywell Elster regulation / metering device | Companion model (from CN1723) |
| Q75 | Honeywell Elster regulation / metering device | Companion model (from CN1724) |
| QA | Honeywell Elster regulation / metering device | Companion model (from CN1725) |
| RABO | Honeywell Elster regulation / metering device | This model (EN page from CN1726) |
| SM-RI-X | Honeywell Elster regulation / metering device | Companion model (from CN1727) |
| TRZ2 | Honeywell Elster regulation / metering device | Companion model (from CN1728) |
| M.Sonic | Honeywell Elster regulation / metering device | Companion model (from CN1729) |
| MAX6 | Honeywell Elster regulation / metering device | Companion model (from CN1730) |
6. Related Models
| Related models | Note |
|---|---|
| Elster SM-RI-X | Companion regulation / metering device in this batch |
| Elster TRZ2 | Companion regulation / metering device in this batch |
7. Common Spare Parts
| Spare part | Part number / note |
|---|---|
| Index / display assembly | See the official spare-parts list; verify with the manufacturer |
| Sensor / rotor assembly | See the official spare-parts list; verify with the manufacturer |
| Seals and O-rings | See the official spare-parts list; verify with the manufacturer |
| Electronic module / communication board | See the official spare-parts list; verify with the manufacturer |
| Pressure / temperature sensor | See the official spare-parts list; verify with the manufacturer |
8. Accessories
| Accessory | Description |
|---|---|
| Electronic volume corrector (EK280 / EK205) | Selected by communication and metering requirements |
| Pulse output module | LF / HF pulser selected by the receiving system |
| Pressure / temperature sensors | Selected by metering accuracy requirements |
| Communication module (GSM/GPRS / Modbus) | Selected by remote-transfer requirements; verify with the manufacturer |
| Other accessories | Refer to the official data sheet |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文
ENGLISH