Elster QUANTOMETER Q75 Turbine Gas Flowmeter DN200-DN600
1. Product Overview
The Honeywell QUANTOMETER Q75. Heavy-industry turbine gas flowmeter, DN200-DN600.
Key technical information is given in the table and Technical Description below. Values not published in official literature are directed to the official data sheet; refer to the official data sheet; verify with the manufacturer.
This page presents only official product positioning and technical data; certification and production status should be verified with the manufacturer.



2. Technical Description
Type: Heavy-industry turbine gas flowmeter, DN200-DN600.
Type: Turbine gas flowmeter (heavy-industry Q75)
Size: DN200-DN600 (8 in to 24 in)
Meter sizes: G65-G16000
Flow range: 6-25,000 m3/h (official brochure)
Turndown: up to 1:20
Body: Cast iron or steel
Temperature: -10 to +60 deg C (other ranges on request)
Connections: Flanges to EN or ASME
Protection: IP67 (outdoor)
Index / output: 8-digit mechanical index, two LF outputs standard
Approvals: DVGW, ATEX, PED
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Type / model | Honeywell Elster QUANTOMETER Q75 |
| Type | Turbine gas flowmeter (heavy-industry Q75) |
| Size | DN200-DN600 (8 in to 24 in) |
| Meter sizes | G65-G16000 |
| Flow range | 6-25,000 m3/h (official brochure) |
| Turndown | up to 1:20 |
| Body | Cast iron or steel |
| Temperature | -10 to +60 deg C (other ranges on request) |
| Connections | Flanges to EN or ASME |
| Protection | IP67 (outdoor) |
| Index / output | 8-digit mechanical index, two LF outputs standard |
| Approvals | DVGW, ATEX, PED |
| Ordering | refer to the official data sheet; verify with the manufacturer |
4. Selection Guide
Selection sequence: Application -> Parameter check -> Selection point -> Accessories -> Approvals.
| Step | Item | Key point |
|---|---|---|
| 1 | Application | Heavy-industry turbine gas flowmeter, DN200-DN600 |
| 2 | Parameter check | Verify size, pressure, flow and accuracy against the official data sheet |
| 3 | Selection point | For DN200-DN600 heavy industrial non-custody metering; Q type below DN150, QA/QAe for light industry; refer to the official data sheet; verify with the manufacturer. |
| 4 | Accessories | Configure volume correction / communication / sensors as required; refer to the official data sheet; verify with the manufacturer. |
| 5 | Approvals | Certification status: refer to the official data sheet; verify with the manufacturer. |
Boundary: For DN200-DN600 heavy industrial non-custody metering; Q type below DN150, QA/QAe for light industry; refer to the official data sheet; verify with the manufacturer. Limits: refer to the official data sheet; verify with the manufacturer.
5. Complete Model Enumeration
| Model | Type | Note |
|---|---|---|
| Elster 5020 | Honeywell Elster regulation / metering device | Companion model (from CN1696) |
| J125B | Honeywell Elster regulation / metering device | Companion model (from CN1697) |
| EK205 | Honeywell Elster regulation / metering device | Companion model (from CN1698) |
| EK280 | Honeywell Elster regulation / metering device | Companion model (from CN1699) |
| FC1 | Honeywell Elster regulation / metering device | Companion model (from CN1700) |
| IRM-3 DUO | Honeywell Elster regulation / metering device | Companion model (from CN1721) |
| Q.Sonic MAX | Honeywell Elster regulation / metering device | Companion model (from CN1722) |
| Q.Sonic PLUS | Honeywell Elster regulation / metering device | Companion model (from CN1723) |
| Q75 | Honeywell Elster regulation / metering device | This model (EN page from CN1724) |
| QA | Honeywell Elster regulation / metering device | Companion model (from CN1725) |
| RABO | Honeywell Elster regulation / metering device | Companion model (from CN1726) |
| SM-RI-X | Honeywell Elster regulation / metering device | Companion model (from CN1727) |
| TRZ2 | Honeywell Elster regulation / metering device | Companion model (from CN1728) |
| M.Sonic | Honeywell Elster regulation / metering device | Companion model (from CN1729) |
| MAX6 | Honeywell Elster regulation / metering device | Companion model (from CN1730) |
6. Related Models
| Related models | Note |
|---|---|
| Elster QA | Companion regulation / metering device in this batch |
| Elster RABO | Companion regulation / metering device in this batch |
7. Common Spare Parts
| Spare part | Part number / note |
|---|---|
| Index / display assembly | See the official spare-parts list; verify with the manufacturer |
| Sensor / rotor assembly | See the official spare-parts list; verify with the manufacturer |
| Seals and O-rings | See the official spare-parts list; verify with the manufacturer |
| Electronic module / communication board | See the official spare-parts list; verify with the manufacturer |
| Pressure / temperature sensor | See the official spare-parts list; verify with the manufacturer |
8. Accessories
| Accessory | Description |
|---|---|
| Electronic volume corrector (EK280 / EK205) | Selected by communication and metering requirements |
| Pulse output module | LF / HF pulser selected by the receiving system |
| Pressure / temperature sensors | Selected by metering accuracy requirements |
| Communication module (GSM/GPRS / Modbus) | Selected by remote-transfer requirements; verify with the manufacturer |
| Other accessories | Refer to the official data sheet |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文