Home » Products » Sulzer
Sulzer SMD Process Pump - 200 - 25,000 m3/h / 1,100 - 110,000 US gpm
Sulzer SMD Process Pump - 200 - 25,000 m3/h / 1,100 - 110,000 US gpm
Sulzer SMD Process Pump - 200 - 25,000 m3/h / 1,100 - 110,000 US gpm

Sulzer SMD Process Pump - 200 - 25,000 m3/h / 1,100 - 110,000 US gpm

Details

1. Product Overview

The Sulzer SMD is a member of the Sulzer process pump line. SMD clean-water pump, single-stage double suction with an axially split casing, available as a standard version (municipal water treatment and distribution) and a configured version (intake, transfer, desalination), with ACS and NSF 61/372 drinking-water certificates.

Official key performance: flow 200 - 25,000 m3/h / 1,100 - 110,000 US gpm; head up to 260 m / 850 ft; pressure up to 34 bar / 490 psi. Media and industries: Raw water, clean water, seawater, brackish water; intake, transfer, desalination, water treatment, water supply and distribution, irrigation, district cooling and heating.

Bore, materials and temperature are not fully published here; refer to the official datasheet; verify with the manufacturer.

Above: product appearance / manufacturer literature image.

2. Technical Description

Type: SMD clean-water pump, single-stage double suction with an axially split casing, available as a standard version (municipal water treatment and distribution) and a configured version (intake, transfer, desalination), with ACS and NSF 61/372 drinking-water certificates.

Performance: Flow 200 - 25,000 m3/h / 1,100 - 110,000 US gpm; head up to 260 m / 850 ft; pressure up to 34 bar / 490 psi.

Temperature / flange: Temperature refer to the official datasheet; verify with the manufacturer; connection / flange refer to the official datasheet; verify with the manufacturer.

Key design: Double-suction impeller balances axial thrust with a wide efficiency range and low NPSHR; full-size double volute reduces radial load; 360-degree bearing bracket; dry-shaft design lets bearings, seals and sleeves be replaced without lifting the upper casing

Media / industries: Raw water, clean water, seawater, brackish water; intake, transfer, desalination, water treatment, water supply and distribution, irrigation, district cooling and heating.

Source: Sulzer official product pages (sulzer.com) and official brochures / data sheets

3. Main Technical Specifications

ParameterSpecification / Description
Type / modelSulzer SMD process pump
Flow range200 - 25,000 m3/h / 1,100 - 110,000 US gpm
Head rangeup to 260 m / 850 ft
Pressure ratingup to 34 bar / 490 psi
Temperature rangerefer to the official datasheet; verify with the manufacturer
Connection / flangerefer to the official datasheet; verify with the manufacturer
Media / industriesRaw water, clean water, seawater, brackish water; intake, transfer, desalination, water treatment, water supply and distribution, irrigation, district cooling and heating
Key design featuresDouble-suction impeller balances axial thrust with a wide efficiency range and low NPSHR; full-size double volute reduces radial load; 360-degree bearing bracket; dry-shaft design lets bearings, seals and sleeves be replaced without lifting the upper casing
Bore / materialsrefer to the official datasheet; verify with the manufacturer
OrderingRefer to the official datasheet; verify with the manufacturer
Source: Sulzer official product pages (sulzer.com) and official brochures / data sheets

4. Selection Guide

Selection sequence: Duty check -> Performance check -> Selection point -> Materials and seals -> Installation and driver.

StepItemKey point
1Duty checkDetermine pump type by media (clean / solids / corrosive), flow and head
2Performance checkVerify flow 200 - 25,000 m3/h / 1,100 - 110,000 US gpm, head up to 260 m / 850 ft, pressure up to 34 bar / 490 psi
3Selection pointChoose the standard version for municipal standardisation and the configured version for intake / transfer / desalination; verify ACS / NSF 61/372 for potable service.
4Materials and sealsConfirm wetted materials and sealing by media; verify with the manufacturer
5Installation and driverInstallation, driver and monitoring per project; refer to the official datasheet

Boundary: Choose the standard version for municipal standardisation and the configured version for intake / transfer / desalination; verify ACS / NSF 61/372 for potable service. Limits: refer to the official datasheet; verify with the manufacturer.

Source: Sulzer official product pages (sulzer.com) and official brochures / data sheets

5. Complete Model Enumeration

ModelTypeNote
PRESulzer process pumpCompanion model (from CN1705)
PRER / PRETRSulzer process pumpCompanion model (from CN1706)
EMWSulzer process pumpCompanion model (from CN1707)
PLRSulzer process pumpCompanion model (from CN1708)
RELSulzer process pumpCompanion model (from CN1709)
ZFnSulzer process pumpCompanion model (from CN1710)
ABS FRSulzer process pumpCompanion model (from CN1711)
HPDMSulzer process pumpCompanion model (from CN1712)
HSASulzer process pumpCompanion model (from CN1713)
HSBSulzer process pumpCompanion model (from CN1714)
SMDSulzer process pumpThis model (EN page from CN1715)
ZPPSulzer process pumpCompanion model (from CN1716)
MSD-ROSulzer process pumpCompanion model (from CN1717)
MSN-ROSulzer process pumpCompanion model (from CN1718)

6. Related Models

Related modelsNote
Sulzer ZPPCompanion process pump in this batch (from CN1716)
Sulzer MSD-ROCompanion process pump in this batch (from CN1717)

7. Common Spare Parts

Spare partPart number / note
Impeller / wear ringsSee the official spare-parts list; verify with the manufacturer
Mechanical seal kitSee the official spare-parts list; verify with the manufacturer
Bearing assemblySee the official spare-parts list; verify with the manufacturer
Casing / stage gasketsSee the official spare-parts list; verify with the manufacturer
Coupling and guardSee the official spare-parts list; verify with the manufacturer

8. Accessories

AccessoryDescription
Driver (motor / turbine)Selected by speed and power; verify with the manufacturer
Coupling and baseplateSelected by installation form
Seal flush plan (API Plan)Plan 11 / 31 / 32 etc. by media; verify with the manufacturer
Monitoring and protection instrumentsVibration / temperature / leakage monitoring per project
Other accessoriesRefer to the official datasheet

9. Disclaimer

The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources & Contact

Source: Sulzer official product pages (sulzer.com) and official brochures / data sheets.

We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area