Home » Products » Honeywell
Elster EK280 Battery-Operated Electronic Volume Corrector for Gas Meters
Elster EK280 Battery-Operated Electronic Volume Corrector for Gas Meters
Elster EK280 Battery-Operated Electronic Volume Corrector for Gas Meters

Elster EK280 Battery-Operated Electronic Volume Corrector for Gas Meters

Details

1. Product Overview

The Honeywell EK280. Battery-operated electronic volume corrector for gas meters and flowmeters.

Key technical information is given in the table and Technical Description below. Values not published in official literature are directed to the official data sheet; refer to the official data sheet; verify with the manufacturer.

This page presents only official product positioning and technical data; certification and production status should be verified with the manufacturer.

Above: product appearance / manufacturer literature image.

2. Technical Description

Type: Battery-operated electronic volume corrector for gas meters and flowmeters.

Type: Electronic volume corrector, battery operated

Pairs with: Diaphragm gas meters, turbine or rotary flowmeters

Pressure sensor: Internal or external absolute sensor (ENVEC CT30), optional second sensor; ranges 0.7-2 to 14-70 bar

Temperature sensor: Pt-500 to DIN 60751 class A, -30 to +60 deg C

Compressibility: S-GERG 88 / AGA 8 (GC1/GC2) / AGA 8 DC-92 / AGA NX-19 / programmable constant

Power: 2 lithium batteries (13 Ah, >5 years standard), optional external 7.5-8.5 VDC

Communication: Optical IEC 62056-21; RS232/RS485; optional GSM/GPRS modem; Modbus RTU/ASCII/TCP, DLMS/COSEM

Approvals: MID (NMI T 10339); EN 12405-1; ATEX zone 1 EEx ia IIB T3/T4, zone 2 EEx ia IIC T6

Source: Honeywell official product pages (honeywell.com.cn, process.honeywell.com) and official Elster data sheets / Bulletins

3. Main Technical Specifications

ParameterSpecification / Description
Type / modelHoneywell Elster EK280
TypeElectronic volume corrector, battery operated
Pairs withDiaphragm gas meters, turbine or rotary flowmeters
Pressure sensorInternal or external absolute sensor (ENVEC CT30), optional second sensor; ranges 0.7-2 to 14-70 bar
Temperature sensorPt-500 to DIN 60751 class A, -30 to +60 deg C
CompressibilityS-GERG 88 / AGA 8 (GC1/GC2) / AGA 8 DC-92 / AGA NX-19 / programmable constant
Power2 lithium batteries (13 Ah, >5 years standard), optional external 7.5-8.5 VDC
CommunicationOptical IEC 62056-21; RS232/RS485; optional GSM/GPRS modem; Modbus RTU/ASCII/TCP, DLMS/COSEM
ApprovalsMID (NMI T 10339); EN 12405-1; ATEX zone 1 EEx ia IIB T3/T4, zone 2 EEx ia IIC T6
Orderingrefer to the official data sheet; verify with the manufacturer
Source: Honeywell official product pages (honeywell.com.cn, process.honeywell.com) and official Elster data sheets / Bulletins

4. Selection Guide

Selection sequence: Application -> Parameter check -> Selection point -> Accessories -> Approvals.

StepItemKey point
1ApplicationBattery-operated electronic volume corrector for gas meters and flowmeters
2Parameter checkVerify size, pressure, flow and accuracy against the official data sheet
3Selection pointFor custody-grade volume correction, remote data transfer and station monitoring; refer to the official data sheet; verify with the manufacturer.
4AccessoriesConfigure volume correction / communication / sensors as required; refer to the official data sheet; verify with the manufacturer.
5ApprovalsCertification status: refer to the official data sheet; verify with the manufacturer.

Boundary: For custody-grade volume correction, remote data transfer and station monitoring; refer to the official data sheet; verify with the manufacturer. Limits: refer to the official data sheet; verify with the manufacturer.

Source: Honeywell official product pages (honeywell.com.cn, process.honeywell.com) and official Elster data sheets / Bulletins

5. Complete Model Enumeration

ModelTypeNote
Elster 5020Honeywell Elster regulation / metering deviceCompanion model (from CN1696)
J125BHoneywell Elster regulation / metering deviceCompanion model (from CN1697)
EK205Honeywell Elster regulation / metering deviceCompanion model (from CN1698)
EK280Honeywell Elster regulation / metering deviceThis model (EN page from CN1699)
FC1Honeywell Elster regulation / metering deviceCompanion model (from CN1700)
IRM-3 DUOHoneywell Elster regulation / metering deviceCompanion model (from CN1721)
Q.Sonic MAXHoneywell Elster regulation / metering deviceCompanion model (from CN1722)
Q.Sonic PLUSHoneywell Elster regulation / metering deviceCompanion model (from CN1723)
Q75Honeywell Elster regulation / metering deviceCompanion model (from CN1724)
QAHoneywell Elster regulation / metering deviceCompanion model (from CN1725)
RABOHoneywell Elster regulation / metering deviceCompanion model (from CN1726)
SM-RI-XHoneywell Elster regulation / metering deviceCompanion model (from CN1727)
TRZ2Honeywell Elster regulation / metering deviceCompanion model (from CN1728)
M.SonicHoneywell Elster regulation / metering deviceCompanion model (from CN1729)
MAX6Honeywell Elster regulation / metering deviceCompanion model (from CN1730)

6. Related Models

Related modelsNote
Elster FC1Companion regulation / metering device in this batch
Elster IRM-3 DUOCompanion regulation / metering device in this batch

7. Common Spare Parts

Spare partPart number / note
Index / display assemblySee the official spare-parts list; verify with the manufacturer
Sensor / rotor assemblySee the official spare-parts list; verify with the manufacturer
Seals and O-ringsSee the official spare-parts list; verify with the manufacturer
Electronic module / communication boardSee the official spare-parts list; verify with the manufacturer
Pressure / temperature sensorSee the official spare-parts list; verify with the manufacturer

8. Accessories

AccessoryDescription
Electronic volume corrector (EK280 / EK205)Selected by communication and metering requirements
Pulse output moduleLF / HF pulser selected by the receiving system
Pressure / temperature sensorsSelected by metering accuracy requirements
Communication module (GSM/GPRS / Modbus)Selected by remote-transfer requirements; verify with the manufacturer
Other accessoriesRefer to the official data sheet

9. Disclaimer

The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources & Contact

Source: Honeywell official product pages (honeywell.com.cn, process.honeywell.com) and official Elster data sheets / Bulletins.

We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area