Elster EK205 Battery-Operated Volume Conversion Device with LCD Display
1. Product Overview
The Honeywell EK205. Battery-operated volume conversion device with LCD display.
Key technical information is given in the table and Technical Description below. Values not published in official literature are directed to the official data sheet; refer to the official data sheet; verify with the manufacturer.
This page presents only official product positioning and technical data; certification and production status should be verified with the manufacturer.



2. Technical Description
Type: Battery-operated volume conversion device with LCD display.
Type: Battery-operated volume converter
Power: Lithium battery, service life >5 years (official brochure)
Display: Monochrome backlit dot-matrix LCD, 128x64, 4-button panel
Volume conversion: To EN 12405; compressibility per AGA-NX19 mod / AGA 8 (GC1/GC2) / AGA 8 DC-92 / S-GERG 88 / fixed
I/O: 2 digital inputs; 2 freely programmable transistor outputs (pulse / status)
Data logging: Monthly 24, daily 600, measurement archive 10,000; logbook 500, audit trail 100
Communication: Optical interface IEC 62056-21; RS232/RS485; Modbus RTU/ASCII/TCP
Mounting: Meter-, pipe- or wall-mount; IP65 (per official data sheet)
Approvals: MID; ATEX / IECEx II 1G Ex ia IIC T4 Ga (per official data sheet)
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Type / model | Honeywell Elster EK205 |
| Type | Battery-operated volume converter |
| Power | Lithium battery, service life >5 years (official brochure) |
| Display | Monochrome backlit dot-matrix LCD, 128x64, 4-button panel |
| Volume conversion | To EN 12405; compressibility per AGA-NX19 mod / AGA 8 (GC1/GC2) / AGA 8 DC-92 / S-GERG 88 / fixed |
| I/O | 2 digital inputs; 2 freely programmable transistor outputs (pulse / status) |
| Data logging | Monthly 24, daily 600, measurement archive 10,000; logbook 500, audit trail 100 |
| Communication | Optical interface IEC 62056-21; RS232/RS485; Modbus RTU/ASCII/TCP |
| Mounting | Meter-, pipe- or wall-mount; IP65 (per official data sheet) |
| Approvals | MID; ATEX / IECEx II 1G Ex ia IIC T4 Ga (per official data sheet) |
| Ordering | refer to the official data sheet; verify with the manufacturer |
4. Selection Guide
Selection sequence: Application -> Parameter check -> Selection point -> Accessories -> Approvals.
| Step | Item | Key point |
|---|---|---|
| 1 | Application | Battery-operated volume conversion device with LCD display |
| 2 | Parameter check | Verify size, pressure, flow and accuracy against the official data sheet |
| 3 | Selection point | For standard-volume conversion and data logging with diaphragm / turbine / rotary meters; refer to the official data sheet; verify with the manufacturer. |
| 4 | Accessories | Configure volume correction / communication / sensors as required; refer to the official data sheet; verify with the manufacturer. |
| 5 | Approvals | Certification status: refer to the official data sheet; verify with the manufacturer. |
Boundary: For standard-volume conversion and data logging with diaphragm / turbine / rotary meters; refer to the official data sheet; verify with the manufacturer. Limits: refer to the official data sheet; verify with the manufacturer.
5. Complete Model Enumeration
| Model | Type | Note |
|---|---|---|
| Elster 5020 | Honeywell Elster regulation / metering device | Companion model (from CN1696) |
| J125B | Honeywell Elster regulation / metering device | Companion model (from CN1697) |
| EK205 | Honeywell Elster regulation / metering device | This model (EN page from CN1698) |
| EK280 | Honeywell Elster regulation / metering device | Companion model (from CN1699) |
| FC1 | Honeywell Elster regulation / metering device | Companion model (from CN1700) |
| IRM-3 DUO | Honeywell Elster regulation / metering device | Companion model (from CN1721) |
| Q.Sonic MAX | Honeywell Elster regulation / metering device | Companion model (from CN1722) |
| Q.Sonic PLUS | Honeywell Elster regulation / metering device | Companion model (from CN1723) |
| Q75 | Honeywell Elster regulation / metering device | Companion model (from CN1724) |
| QA | Honeywell Elster regulation / metering device | Companion model (from CN1725) |
| RABO | Honeywell Elster regulation / metering device | Companion model (from CN1726) |
| SM-RI-X | Honeywell Elster regulation / metering device | Companion model (from CN1727) |
| TRZ2 | Honeywell Elster regulation / metering device | Companion model (from CN1728) |
| M.Sonic | Honeywell Elster regulation / metering device | Companion model (from CN1729) |
| MAX6 | Honeywell Elster regulation / metering device | Companion model (from CN1730) |
6. Related Models
| Related models | Note |
|---|---|
| Elster EK280 | Companion regulation / metering device in this batch |
| Elster FC1 | Companion regulation / metering device in this batch |
7. Common Spare Parts
| Spare part | Part number / note |
|---|---|
| Index / display assembly | See the official spare-parts list; verify with the manufacturer |
| Sensor / rotor assembly | See the official spare-parts list; verify with the manufacturer |
| Seals and O-rings | See the official spare-parts list; verify with the manufacturer |
| Electronic module / communication board | See the official spare-parts list; verify with the manufacturer |
| Pressure / temperature sensor | See the official spare-parts list; verify with the manufacturer |
8. Accessories
| Accessory | Description |
|---|---|
| Electronic volume corrector (EK280 / EK205) | Selected by communication and metering requirements |
| Pulse output module | LF / HF pulser selected by the receiving system |
| Pressure / temperature sensors | Selected by metering accuracy requirements |
| Communication module (GSM/GPRS / Modbus) | Selected by remote-transfer requirements; verify with the manufacturer |
| Other accessories | Refer to the official data sheet |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文
ENGLISH