Honeywell Elster 402 Pilot-operated Regulating and Shut-off Valve DN25-100
1. Product Overview
The Honeywell HON 402 is a pilot-operated regulating and shut-off integrated valve for gas transmission regulation stations, gas plants and industrial users with inlet pressure up to 50 bar. It combines pressure reduction and safety shut-off in one body.
Official literature lists DN25 to DN100 with PN16, PN25 and ANSI 150 to 300 flanges. The outlet pressure range is 20 mbar to 40 bar, with accuracy class AC1 to AC20 by outlet band, shut-off class SG10 and shut-off zone SZ2.5. An internal HON 620 pilot or an external HON 630 series pilot can be selected, and an integrated safety shut-off valve can be fitted.
This page is a selection overview. The temperature range is per the official data sheet and refer to the official datasheet; verify with the manufacturer.



2. Technical Description
Design: Globe pilot-operated regulator with an optional integrated shut-off valve, few parts and quiet operation.
Size range: DN25 to DN100.
Connections: PN16, PN25 and ANSI 150 to 300 flanges; at DN25 the outlet DN equals the inlet DN, and at DN50 to DN100 the outlet DN is twice the inlet DN.
Pressure: Maximum inlet pressure 50 bar; maximum allowable pressure 25 bar with the HON 625 regulator or 40 bar with the HON 630 and 630-1 pilots; outlet pressure 20 mbar to 40 bar.
Control: Internal HON 620 pilot or external HON 630 series pilot, with the HON 630-1 as a single stage type; accuracy AC1 to AC20 by outlet band, shut-off class SG10, shut-off zone SZ2.5; minimum differential 0.5 bar.
SSV and construction: Optional integrated SSV with Wdo 40 mbar to 40 bar and Wdu 5 mbar to 40 bar; ductile iron GJS or cast steel GS body; NBR and ECO diaphragms; CE (PED/GAD).
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Product type | Pilot-operated regulating and shut-off integrated valve |
| Series / model | Honeywell Elster HON 402 |
| Size range | DN25-DN100 |
| Max inlet pressure | 50 bar |
| Max allowable pressure | 25 bar with HON 625; 40 bar with HON 630 and 630-1 |
| Pressure class / connection | PN16, PN25, ANSI 150-300; flanged; outlet DN equals inlet DN at DN25 and is twice inlet DN at DN50 to DN100 |
| Medium | DVGW G260 natural gas and neutral non-corrosive gas; other gases on consultation |
| Outlet pressure range | 20 mbar-40 bar (Chinese site 0.02-40 bar) |
| Pilot options | Internal HON 620 or external HON 630 series pilot; HON 630-1 single stage type |
| Accuracy / shut-off | AC1 to AC20 by outlet band; shut-off class SG10; shut-off zone SZ2.5 |
| Minimum differential | 0.5 bar |
| Integrated SSV settings | Overpressure Wdo 40 mbar-40 bar; underpressure Wdu 5 mbar-40 bar |
| Materials / approvals | Ductile iron GJS or cast steel GS body; NBR and ECO diaphragms; CE (PED/GAD); ATEX 95 not applicable to mechanical parts; refer to the official datasheet; verify with the manufacturer |
4. Selection Guide
Selection sequence: Duty definition -> Size and connection -> Pressure check -> Pilot selection -> SSV and options -> Verification.
| Step | Item | Key point |
|---|---|---|
| 1 | Duty definition | Confirm a station duty needing regulation and shut-off in one valve |
| 2 | Size and connection | Check DN25 to DN100 and the PN or ANSI flange and outlet DN relation |
| 3 | Pressure check | Confirm inlet within 50 bar and the allowable pressure for the selected pilot |
| 4 | Pilot selection | Choose the internal HON 620 or external HON 630 series pilot from the inlet conditions |
| 5 | SSV and options | Specify the integrated SSV settings, noise reduction, outlet expansion and remote position as required |
| 6 | Verification | Confirm temperature and final configuration on the official data sheet; refer to the official datasheet; verify with the manufacturer |
Boundary: For DN25 to DN100 duties with inlet pressure up to 50 bar that need regulation and shut-off in one body. Choose the internal HON 620 or external HON 630 pilot according to inlet variation; refer to the official datasheet; verify with the manufacturer.
5. Complete Model Enumeration
| Model | Family / function | Key specification |
|---|---|---|
| HON 711 | Axial flow safety shut-off valve | DN25-400; overpressure and underpressure shut-off; DIN EN 14382 |
| HON HSV086 | Pilot-operated globe safety shut-off valve | DN25-500; ANSI 150-1500; accuracy class AC1; response under 1 s |
| Elster Jeavons S100 | Spring loaded slam shut valve | DN50-100; 19 bar inlet; full bore; BS EN 14382 |
| HON 305 | Self-operated safety shut-off valve | DN50-200; up to 19 bar; single inline orifice |
| HON 512 | Axial flow pilot pressure regulator | DN25-300; outlet 0.3-90 bar; AC1 / SG5 |
| HON R100 | Globe pilot high pressure regulator | DN25-400; high differential; optional cage silencer |
| HON R100NG | Globe pilot high pressure regulator | DN25-200; HON P095NG pilot; fail-closed or fail-open |
| HON R-50 | Dome loaded high pressure regulator | ANSI 1500 design; accuracy within 1 percent |
| HON Elster AFV | Axial flow valve for multi-purpose use | DN50-300; ANSI 300 / 600; reversible sleeve |
| Elster Jeavons J123 | Spring loaded direct acting regulator | 2 in to 4 in; 4 bar inlet; outlet up to 350 mbar |
| Elster Jeavons J123HP | High outlet spring loaded regulator | 2 in and 3 in; 4 bar inlet; outlet around 1 bar |
| HON 530 | Electric flow and pressure control valve | DN50-500; equal percentage and linear; AC1 |
| HON C210S | Globe flow control valve | DN50-400; noise reduction up to 40 dB(A); electric or pneumatic |
| HON 274 | Lever spring loaded regulator with integrated SSV | 1-1/4 to 2 in thread, DN50 flange; outlet 15-420 mbar |
| HON 370 | Spring loaded direct acting regulator | DN25-150; 20 bar; outlet 20 mbar-4 bar |
| HON 372 | Pilot-operated regulator with integrated SSV | DN25-150; outlet 10 mbar-15 bar; AC1 to AC10 |
| HON 402 | Pilot-operated regulating and shut-off valve | DN25-100; inlet up to 50 bar; outlet 20 mbar-40 bar |
6. Related Models
| Related model | Description |
|---|---|
| HON 620 pilot | Internal pilot option for the HON 402 regulator |
| HON 630 series pilot | External pilot option for the HON 402 regulator |
| HON 372 | Pilot-operated regulator on a lower pressure platform |
| HON 711 | Safety shut-off valve for separate downstream protection |
7. Common Spare Parts
| Spare part | Description |
|---|---|
| Pilot spare set | Matched to the HON 620 or HON 630 pilot fitted |
| Diaphragm set | NBR or ECO matched to the original material |
| Seat and internal trim | Matched to the DN size and outlet pressure band |
| SSV control set | Matched to the integrated shut-off valve where fitted |
8. Accessories
| Accessory | Description |
|---|---|
| Integrated SSV | Overpressure and underpressure shut-off in one body |
| Internal silencer | Retrofittable noise reduction |
| Outlet expansion | Enlarged outlet connection where required |
| Shut-off position remote indication | Reports SSV status to the control system; Ordering code per the official datasheet; verify with the manufacturer |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China