Honeywell Elster 370 Spring Loaded Gas Regulator DN25-150
1. Product Overview
The Honeywell HON 370 is a spring loaded direct acting gas regulator for commercial and industrial users, regional distribution stations and dynamic regulating lines serving boilers, burners and engines. Family versions include an integrated overpressure protection (IS) type and a fail-open (FO) type.
Official literature lists DN25 to DN150, a maximum allowable pressure and maximum inlet pressure of up to 20 bar, and DIN PN16 or ANSI Class 150 flanges. The outlet pressure range is 20 mbar to 4 bar with shut-off pressure zone SZ2.5. The inlet pressure compensated diaphragm, integrated safety relief and shut-off options, and cartridge style functional modules make the regulator compact and easy to maintain.
This page is a selection overview. Flange options other than PN16 and Class 150 require consultation; final data are per the official datasheet and refer to the official datasheet; verify with the manufacturer.

2. Technical Description
Design: Direct acting regulator with an inlet pressure compensation diaphragm and cartridge style functional modules.
Size range: DN25 to DN150.
Connections: DIN flange PN16 or ANSI Class 150 (ANSI 16.5); other flanges on consultation.
Pressure: Maximum allowable pressure and maximum inlet pressure up to 20 bar; outlet pressure 20 mbar to 4 bar; shut-off pressure zone SZ2.5.
Safety options: Integrated overpressure protection IS; optional safety relief valve set 15-90 mbar above Pds or safety diaphragm; optional integrated SSV with overpressure setting 25 mbar to 5.2 bar and underpressure setting 5-400 mbar, in EN 14382 functional class A or B.
Construction and approvals: Ductile iron body with no ignition source in the mechanical parts so ATEX 95 does not apply; electronic accessories meet ATEX; temperature -20 C to +60 C; CE (PED).
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Product type | Spring loaded direct acting gas regulator |
| Series / model | Honeywell Elster HON 370; family includes IS and FO versions |
| Size range | DN25-DN150 |
| Max allowable / inlet pressure | Both up to 20 bar |
| Pressure class / connection | DIN PN16 or ANSI Class 150 (ANSI 16.5); other flanges on consultation |
| Medium | DVGW G260 natural gas and neutral non-corrosive gas; other gases on consultation |
| Outlet pressure range | 20 mbar-4 bar |
| Shut-off pressure zone | SZ2.5 |
| Integrated protection | IS overpressure protection; optional SSV overpressure 25 mbar-5.2 bar and underpressure 5-400 mbar, EN 14382 class A or B |
| Relief option | Optional safety relief valve set 15-90 mbar above Pds or safety diaphragm |
| Pilot of SSV | Pressure balancing valve giving an internal bypass |
| Body material / temperature | Ductile iron body; -20 C to +60 C; ATEX 95 not applicable to mechanical parts |
| Approvals / options | CE (PED); noise reduction and cartridge modules; suitable for gas appliances under 90/396/EEC; refer to the official datasheet; verify with the manufacturer |
4. Selection Guide
Selection sequence: Duty definition -> Size and connection -> Pressure check -> Protection needs -> Dynamic duty -> Verification.
| Step | Item | Key point |
|---|---|---|
| 1 | Duty definition | Confirm a commercial, industrial or regional distribution regulating duty |
| 2 | Size and connection | Check DN25 to DN150 and the PN16 or ANSI Class 150 flange |
| 3 | Pressure check | Confirm inlet up to 20 bar and the required outlet between 20 mbar and 4 bar |
| 4 | Protection needs | Specify IS, safety relief, safety diaphragm or integrated SSV with the required EN 14382 class |
| 5 | Dynamic duty | Check the regulator for boiler, burner or engine supply and add noise reduction if needed |
| 6 | Verification | Confirm the final configuration on the official data sheet; refer to the official datasheet; verify with the manufacturer |
Boundary: For commercial and industrial stations and combustion equipment needing direct acting accuracy with integrated relief or shut-off. For higher pilot-operated capacity use the HON 372 on the same platform; refer to the official datasheet; verify with the manufacturer.
5. Complete Model Enumeration
| Model | Family / function | Key specification |
|---|---|---|
| HON 711 | Axial flow safety shut-off valve | DN25-400; overpressure and underpressure shut-off; DIN EN 14382 |
| HON HSV086 | Pilot-operated globe safety shut-off valve | DN25-500; ANSI 150-1500; accuracy class AC1; response under 1 s |
| Elster Jeavons S100 | Spring loaded slam shut valve | DN50-100; 19 bar inlet; full bore; BS EN 14382 |
| HON 305 | Self-operated safety shut-off valve | DN50-200; up to 19 bar; single inline orifice |
| HON 512 | Axial flow pilot pressure regulator | DN25-300; outlet 0.3-90 bar; AC1 / SG5 |
| HON R100 | Globe pilot high pressure regulator | DN25-400; high differential; optional cage silencer |
| HON R100NG | Globe pilot high pressure regulator | DN25-200; HON P095NG pilot; fail-closed or fail-open |
| HON R-50 | Dome loaded high pressure regulator | ANSI 1500 design; accuracy within 1 percent |
| HON Elster AFV | Axial flow valve for multi-purpose use | DN50-300; ANSI 300 / 600; reversible sleeve |
| Elster Jeavons J123 | Spring loaded direct acting regulator | 2 in to 4 in; 4 bar inlet; outlet up to 350 mbar |
| Elster Jeavons J123HP | High outlet spring loaded regulator | 2 in and 3 in; 4 bar inlet; outlet around 1 bar |
| HON 530 | Electric flow and pressure control valve | DN50-500; equal percentage and linear; AC1 |
| HON C210S | Globe flow control valve | DN50-400; noise reduction up to 40 dB(A); electric or pneumatic |
| HON 274 | Lever spring loaded regulator with integrated SSV | 1-1/4 to 2 in thread, DN50 flange; outlet 15-420 mbar |
| HON 370 | Spring loaded direct acting regulator | DN25-150; 20 bar; outlet 20 mbar-4 bar |
| HON 372 | Pilot-operated regulator with integrated SSV | DN25-150; outlet 10 mbar-15 bar; AC1 to AC10 |
| HON 402 | Pilot-operated regulating and shut-off valve | DN25-100; inlet up to 50 bar; outlet 20 mbar-40 bar |
6. Related Models
| Related model | Description |
|---|---|
| HON 372 | Pilot-operated regulator on the same platform with higher capacity |
| HON 370 IS | Version with integrated overpressure protection |
| HON 370 FO | Fail-open version for specific safety duties |
| Elster Jeavons J123 | Direct acting regulator for smaller distribution sizes |
7. Common Spare Parts
| Spare part | Description |
|---|---|
| Cartridge module | Functional cartridge matched to the regulator configuration |
| Diaphragm set | NBR diaphragm matched to the original actuator |
| Seat and valve insert | Matched to the DN size and outlet range |
| SSV control set | Matched to the integrated shut-off valve where fitted |
8. Accessories
| Accessory | Description |
|---|---|
| Safety relief valve | Set 15-90 mbar above Pds |
| Integrated SSV | Overpressure and underpressure shut-off in class A or B |
| Noise reduction insert | For low noise operation where required |
| Position indication | Local or remote indication where offered; Ordering code per the official datasheet; verify with the manufacturer |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文
ENGLISH