Honeywell Elster 274 Spring Loaded Gas Regulator with Integrated SSV
1. Product Overview
The Honeywell HON 274 is a lever type, spring loaded direct acting gas regulator from American Meter. It can be supplied with an integrated safety shut-off valve (SSV) for overpressure and underpressure protection and is used for industrial and residential smaller flow duties.
Official literature gives a maximum inlet pressure of 10.3 bar (150 psi) and a maximum allowable operating pressure of 8.6 bar (125 psi) depending on orifice diameter. Connections include threaded 1-1/4 in, 1-1/2 in and 2 in in NPT, BSPT or BSPP and a DN50 flange in ANSI 150 or PN16. Outlet pressure spans 15 to 420 mbar across five spring ranges, with balanced valve and interchangeable orifice options.
This page is a selection overview. Material, temperature and flow coefficient figures are per the official data sheet and refer to the official datasheet; verify with the manufacturer.



2. Technical Description
Design: Lever type spring loaded direct acting regulator with fast response and a balanced valve option.
Connections: Threaded 1-1/4 in, 1-1/2 in and 2 in in NPT, BSPT or BSPP; DN50 flange in ANSI 150 or PN16.
Pressure: Maximum inlet pressure 10.3 bar (150 psi); maximum allowable operating pressure 8.6 bar (125 psi) depending on orifice diameter.
Outlet range: 15-420 mbar (6 in w.c. to 6.0 psi) across five spring ranges; several interchangeable orifices.
Options: Internal relief in full, limited or no relief execution; safety diaphragm; internal or external sensing; a 1 in threaded relief port; several integrated SSV models such as 274LR-309, 274P-309 and 274SD-309.
Approvals: CSA 6.22 line regulator certification; PFM fixed factor accuracy within 1 percent absolute pressure; material, temperature and flow coefficient are refer to the official datasheet; verify with the manufacturer.
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Product type | Lever spring loaded direct acting gas regulator |
| Series / model | Honeywell Elster HON 274 (American Meter) |
| Max inlet pressure | 10.3 bar (150 psi) |
| Max allowable operating pressure | 8.6 bar (125 psi) depending on orifice diameter |
| Threaded connections | 1-1/4 in, 1-1/2 in and 2 in in NPT, BSPT or BSPP |
| Flanged connection | DN50 in ANSI 150 or PN16 |
| Medium | Natural and manufactured gas and other non-corrosive gases including nitrogen, carbon dioxide, propane and butane |
| Outlet pressure range | 15-420 mbar (6 in w.c. to 6.0 psi) across five spring ranges |
| Orifices and balance | Several interchangeable orifices; balanced valve version for improved accuracy |
| Relief and sensing | Internal relief in full, limited or none execution; safety diaphragm; internal or external sensing; 1 in threaded relief port |
| Integrated SSV options | 274LR-309, 274P-309 and 274SD-309 among the overpressure and underpressure versions |
| Approvals | CSA 6.22 line regulator certification; PFM accuracy within 1 percent absolute pressure |
| Material / temperature / flow | refer to the official datasheet; verify with the manufacturer |
4. Selection Guide
Selection sequence: Duty definition -> Connection check -> Pressure check -> Spring and orifice -> Protection options -> Verification.
| Step | Item | Key point |
|---|---|---|
| 1 | Duty definition | Confirm a smaller flow industrial or residential regulating duty |
| 2 | Connection check | Choose between the threaded sizes and the DN50 flange |
| 3 | Pressure check | Confirm inlet within 10.3 bar and operating pressure within 8.6 bar |
| 4 | Spring and orifice | Select the spring range for 15-420 mbar and the suitable interchangeable orifice |
| 5 | Protection options | Specify the relief execution, sensing location and integrated SSV configuration |
| 6 | Verification | Confirm material, temperature and flow coefficient on the official data sheet; refer to the official datasheet; verify with the manufacturer |
Boundary: For industrial and residential small flow duties that need an integrated overpressure and underpressure shut-off valve. Distinguish the P version without relief, the R and LR versions with relief and the SD version with a safety diaphragm; refer to the official datasheet; verify with the manufacturer.
5. Complete Model Enumeration
| Model | Family / function | Key specification |
|---|---|---|
| HON 711 | Axial flow safety shut-off valve | DN25-400; overpressure and underpressure shut-off; DIN EN 14382 |
| HON HSV086 | Pilot-operated globe safety shut-off valve | DN25-500; ANSI 150-1500; accuracy class AC1; response under 1 s |
| Elster Jeavons S100 | Spring loaded slam shut valve | DN50-100; 19 bar inlet; full bore; BS EN 14382 |
| HON 305 | Self-operated safety shut-off valve | DN50-200; up to 19 bar; single inline orifice |
| HON 512 | Axial flow pilot pressure regulator | DN25-300; outlet 0.3-90 bar; AC1 / SG5 |
| HON R100 | Globe pilot high pressure regulator | DN25-400; high differential; optional cage silencer |
| HON R100NG | Globe pilot high pressure regulator | DN25-200; HON P095NG pilot; fail-closed or fail-open |
| HON R-50 | Dome loaded high pressure regulator | ANSI 1500 design; accuracy within 1 percent |
| HON Elster AFV | Axial flow valve for multi-purpose use | DN50-300; ANSI 300 / 600; reversible sleeve |
| Elster Jeavons J123 | Spring loaded direct acting regulator | 2 in to 4 in; 4 bar inlet; outlet up to 350 mbar |
| Elster Jeavons J123HP | High outlet spring loaded regulator | 2 in and 3 in; 4 bar inlet; outlet around 1 bar |
| HON 530 | Electric flow and pressure control valve | DN50-500; equal percentage and linear; AC1 |
| HON C210S | Globe flow control valve | DN50-400; noise reduction up to 40 dB(A); electric or pneumatic |
| HON 274 | Lever spring loaded regulator with integrated SSV | 1-1/4 to 2 in thread, DN50 flange; outlet 15-420 mbar |
| HON 370 | Spring loaded direct acting regulator | DN25-150; 20 bar; outlet 20 mbar-4 bar |
| HON 372 | Pilot-operated regulator with integrated SSV | DN25-150; outlet 10 mbar-15 bar; AC1 to AC10 |
| HON 402 | Pilot-operated regulating and shut-off valve | DN25-100; inlet up to 50 bar; outlet 20 mbar-40 bar |
6. Related Models
| Related model | Description |
|---|---|
| HON 274LR-309 | 274 version with relief and an integrated shut-off valve |
| HON 274P-309 | 274 version without relief and with an integrated shut-off valve |
| HON 274SD-309 | 274 version with a safety diaphragm and integrated shut-off |
| Elster Jeavons J123 | Larger direct acting regulator for distribution duties |
7. Common Spare Parts
| Spare part | Description |
|---|---|
| Spring range set | One of the five springs covering 15-420 mbar |
| Interchangeable orifice | Matched to the required flow and outlet pressure |
| Diaphragm | Standard or safety diaphragm matched to the configuration |
| Relief valve insert | Full or limited relief insert matched to the chosen execution |
8. Accessories
| Accessory | Description |
|---|---|
| Integrated SSV module | Overpressure or underpressure shut-off version; Ordering code per the official datasheet; verify with the manufacturer |
| External sensing kit | Pilot line for downstream pressure sensing |
| Threaded relief adapter | For the 1 in threaded relief port |
| Union and flange adapters | Matched to the threaded or flanged connection |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China