Honeywell Elster R100 High Pressure Globe Regulator DN25-400
1. Product Overview
The Honeywell HON R100 is a high pressure globe type pilot-controlled regulator used where a national trunk line enters a regional distribution network and in large power plants and industrial plants. The family includes R100S with a cage silencer, R100-SO in fail-open execution, R100(S)-M in monitor execution and R101S with a composite silencer.
Official literature lists DN25 to DN400 with RF and RTJ flanges. The Chinese data give a higher maximum inlet pressure and ANSI range than the English product page, so both sets of figures are shown. The valve offers in-line maintenance, an internal silencer and a quick direct-acting response alongside pilot control.
This page is a selection overview. Where official sources give different figures for the same item, both are shown side by side; final data are per the official datasheet and refer to the official datasheet; verify with the manufacturer.



2. Technical Description
Design: Globe pilot-controlled regulator with direct-acting fast response; serviceable in line.
Size range: DN25 to DN400.
Connections: RF and RTJ flanges; the English product page lists ANSI 150, 300 and 600.
Pressure: Chinese data give 250 bar maximum inlet pressure and ANSI 150-1500; the English page gives 100 bar maximum operating pressure and 1.0-60 bar outlet, while the Chinese data sheet gives 0.5-60 bar outlet at the pilot.
Control accuracy: Chinese data give 0.5-100 bar set pressure, AC1 accuracy, SG2.5 shut-off class and SZ2.5 shut-off zone; the English page gives AC5 / SG10 for 1.0-3.0 bar and AC1 / SG2.5 for 3.0-60 bar, with SZ2.5 shut-off zone.
Construction and approvals: A352-LCC (QT) body; temperature -20 C to +60 C (Class 2); DVGW and CE (PED); R100S cage silencer can reduce noise by up to 40 dB(A).
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Product type | High pressure globe pilot regulator |
| Series / model | Honeywell Elster HON R100; family includes R100S, R100-SO, R100(S)-M and R101S |
| Size range | DN25-DN400 |
| Max inlet pressure | Chinese data 250 bar; English page 100 bar maximum operating; official datasheet governs |
| Outlet pressure range | Chinese data sheet 0.5-60 bar; English page 1.0-60 bar |
| Pressure class / connection | Chinese data ANSI 150-1500; English page ANSI 150, 300, 600; flanges RF / RTJ |
| Medium | Natural gas in Chinese data; sweet natural gas on the English page; other gases on consultation |
| Set pressure / accuracy | Chinese data 0.5-100 bar, AC1, SG2.5, SZ2.5; English page AC5 / SG10 at 1.0-3.0 bar and AC1 / SG2.5 at 3.0-60 bar |
| Minimum start-up differential | 0.5 bar |
| Body material | A352-LCC (QT) |
| Temperature range | -20 C to +60 C (Class 2) |
| Approvals | DVGW, CE (PED) |
| Other details | refer to the official datasheet; verify with the manufacturer |
4. Selection Guide
Selection sequence: Duty definition -> Size and connection -> Pressure check -> Accuracy and flow -> Noise and options -> Verification.
| Step | Item | Key point |
|---|---|---|
| 1 | Duty definition | Confirm a high pressure offtake, power plant or industrial regulating duty |
| 2 | Size and connection | Check DN25 to DN400 and the RF or RTJ flange and ANSI class |
| 3 | Pressure check | Reconcile the inlet and outlet figures against the official data sheet for the selected execution |
| 4 | Accuracy and flow | Check the AC and SG figures against the outlet pressure band of the duty |
| 5 | Noise and options | Select the R100S cage silencer where noise is a concern; add remote position or control as required |
| 6 | Verification | Confirm the final configuration on the official data sheet; refer to the official datasheet; verify with the manufacturer |
Boundary: For high differential pressure and large size regulating duties at offtake stations and plants. For noise sensitive sites choose a family member with a cage or composite silencer. Final data are per the official datasheet; refer to the official datasheet; verify with the manufacturer.
5. Complete Model Enumeration
| Model | Family / function | Key specification |
|---|---|---|
| HON 711 | Axial flow safety shut-off valve | DN25-400; overpressure and underpressure shut-off; DIN EN 14382 |
| HON HSV086 | Pilot-operated globe safety shut-off valve | DN25-500; ANSI 150-1500; accuracy class AC1; response under 1 s |
| Elster Jeavons S100 | Spring loaded slam shut valve | DN50-100; 19 bar inlet; full bore; BS EN 14382 |
| HON 305 | Self-operated safety shut-off valve | DN50-200; up to 19 bar; single inline orifice |
| HON 512 | Axial flow pilot pressure regulator | DN25-300; outlet 0.3-90 bar; AC1 / SG5 |
| HON R100 | Globe pilot high pressure regulator | DN25-400; high differential; optional cage silencer |
| HON R100NG | Globe pilot high pressure regulator | DN25-200; HON P095NG pilot; fail-closed or fail-open |
| HON R-50 | Dome loaded high pressure regulator | ANSI 1500 design; accuracy within 1 percent |
| HON Elster AFV | Axial flow valve for multi-purpose use | DN50-300; ANSI 300 / 600; reversible sleeve |
| Elster Jeavons J123 | Spring loaded direct acting regulator | 2 in to 4 in; 4 bar inlet; outlet up to 350 mbar |
| Elster Jeavons J123HP | High outlet spring loaded regulator | 2 in and 3 in; 4 bar inlet; outlet around 1 bar |
| HON 530 | Electric flow and pressure control valve | DN50-500; equal percentage and linear; AC1 |
| HON C210S | Globe flow control valve | DN50-400; noise reduction up to 40 dB(A); electric or pneumatic |
| HON 274 | Lever spring loaded regulator with integrated SSV | 1-1/4 to 2 in thread, DN50 flange; outlet 15-420 mbar |
| HON 370 | Spring loaded direct acting regulator | DN25-150; 20 bar; outlet 20 mbar-4 bar |
| HON 372 | Pilot-operated regulator with integrated SSV | DN25-150; outlet 10 mbar-15 bar; AC1 to AC10 |
| HON 402 | Pilot-operated regulating and shut-off valve | DN25-100; inlet up to 50 bar; outlet 20 mbar-40 bar |
6. Related Models
| Related model | Description |
|---|---|
| HON R100S | R100 version with a cage silencer for reduced noise |
| HON R100-SO | Fail-open version of the R100 regulator |
| HON R100(S)-M | Monitor version for a series regulation loop |
| HON 512 | Axial flow regulator offering an alternative at high flow and low differential |
7. Common Spare Parts
| Spare part | Description |
|---|---|
| Pilot spare set | Matched to the pilot supplied with the regulator |
| Seat and cage trim | Matched to the DN size and to the silencer execution |
| Diaphragm set | Matched to the original actuator diaphragm material |
| Silencer insert | Cage or composite insert matched to the fitted noise reduction option |
8. Accessories
| Accessory | Description |
|---|---|
| Cage silencer | Reduces noise by up to 40 dB(A) on the R100S version |
| Remote position indication | Reports valve position to the station control system |
| Remote set point control | Allows adjustment from a control room where offered |
| Monitor pilot kit | Converts the regulator to a monitor arrangement |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China