Honeywell Elster 305 Self-operated Safety Shut-off Valve Single Orifice
1. Product Overview
The Honeywell HON 305 is a single inline orifice, self-operated overpressure safety shut-off valve. It needs no external power or air supply and can be supplied as an overpressure and underpressure combination.
Official literature lists DN50, DN80, DN100, DN150 and DN200 with a maximum inlet pressure of up to 19 bar depending on body material and size. The valve uses an external pilot line to the outlet side, a torsion spring for fast and tight closure, a pressure balancing bypass and a fully enclosed position indicator that shows the state by colour.
This page is a selection overview. Flange and pilot line details are per the official data sheet and refer to the official datasheet; verify with the manufacturer.



2. Technical Description
Design: Single inline orifice, self-operated shut-off valve with no external power source.
Size range: DN50, DN80, DN100, DN150 and DN200.
Pressure: Maximum inlet pressure up to 19 bar, depending on body material and pipe size.
Control: External pilot line connected to the outlet side; overpressure trigger with manual reset and pressure balancing bypass.
Construction: Torsion spring for rapid tight closure; fully enclosed colour-coded position indicator; integral push-button pressure balancing valve; special valve shaft and seal remove the effect of inlet pressure variation on the trip setting.
Approvals: CE (PED) and V9; mechanical parts have no potential ignition source so ATEX 95 does not apply, while electronic accessories meet ATEX.
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Product type | Self-operated overpressure safety shut-off valve |
| Series / model | Honeywell Elster HON 305 |
| Size range | DN50, DN80, DN100, DN150, DN200 |
| Max inlet pressure | Up to 19 bar depending on body material and size |
| Control connection | External pilot line to the outlet side; flange specification per official data sheet |
| Medium | Natural gas, non-corrosive and manufactured gas; nitrogen, carbon dioxide and propane; other gases on consultation |
| Trigger type | Overpressure trigger with optional underpressure combination; manual reset |
| Pressure balancing | Integral push-button pressure balancing valve and bypass |
| Position indication | Fully enclosed indicator showing state by colour |
| Trip setting stability | Special valve shaft and seal reduce the effect of inlet pressure variation on the set point |
| Temperature range | -20 C to +60 C |
| Approvals | CE (PED); V9; ATEX 95 not applicable to mechanical parts |
| Other details | refer to the official datasheet; verify with the manufacturer |
4. Selection Guide
Selection sequence: Duty definition -> Size and connection -> Pressure check -> Medium check -> Indication and reset -> Verification.
| Step | Item | Key point |
|---|---|---|
| 1 | Duty definition | Confirm a purely self-operated overpressure or combined shut-off duty |
| 2 | Size and connection | Check DN50 to DN200 and the flange specification on the official data sheet |
| 3 | Pressure check | Confirm inlet pressure within the 19 bar limit for the chosen material and size |
| 4 | Medium check | Verify the gas type against the listed natural, non-corrosive, manufactured and LPG gases |
| 5 | Indication and reset | Specify the enclosed position indicator, manual reset and any remote position option |
| 6 | Verification | Confirm the final configuration on the official data sheet; refer to the official datasheet; verify with the manufacturer |
Boundary: For stations upstream of a regulator where no air or electrical supply is available and low pressure loss is required. Final data are per the official datasheet; refer to the official datasheet; verify with the manufacturer.
5. Complete Model Enumeration
| Model | Family / function | Key specification |
|---|---|---|
| HON 711 | Axial flow safety shut-off valve | DN25-400; overpressure and underpressure shut-off; DIN EN 14382 |
| HON HSV086 | Pilot-operated globe safety shut-off valve | DN25-500; ANSI 150-1500; accuracy class AC1; response under 1 s |
| Elster Jeavons S100 | Spring loaded slam shut valve | DN50-100; 19 bar inlet; full bore; BS EN 14382 |
| HON 305 | Self-operated safety shut-off valve | DN50-200; up to 19 bar; single inline orifice |
| HON 512 | Axial flow pilot pressure regulator | DN25-300; outlet 0.3-90 bar; AC1 / SG5 |
| HON R100 | Globe pilot high pressure regulator | DN25-400; high differential; optional cage silencer |
| HON R100NG | Globe pilot high pressure regulator | DN25-200; HON P095NG pilot; fail-closed or fail-open |
| HON R-50 | Dome loaded high pressure regulator | ANSI 1500 design; accuracy within 1 percent |
| HON Elster AFV | Axial flow valve for multi-purpose use | DN50-300; ANSI 300 / 600; reversible sleeve |
| Elster Jeavons J123 | Spring loaded direct acting regulator | 2 in to 4 in; 4 bar inlet; outlet up to 350 mbar |
| Elster Jeavons J123HP | High outlet spring loaded regulator | 2 in and 3 in; 4 bar inlet; outlet around 1 bar |
| HON 530 | Electric flow and pressure control valve | DN50-500; equal percentage and linear; AC1 |
| HON C210S | Globe flow control valve | DN50-400; noise reduction up to 40 dB(A); electric or pneumatic |
| HON 274 | Lever spring loaded regulator with integrated SSV | 1-1/4 to 2 in thread, DN50 flange; outlet 15-420 mbar |
| HON 370 | Spring loaded direct acting regulator | DN25-150; 20 bar; outlet 20 mbar-4 bar |
| HON 372 | Pilot-operated regulator with integrated SSV | DN25-150; outlet 10 mbar-15 bar; AC1 to AC10 |
| HON 402 | Pilot-operated regulating and shut-off valve | DN25-100; inlet up to 50 bar; outlet 20 mbar-40 bar |
6. Related Models
| Related model | Description |
|---|---|
| Elster Jeavons S100 | Spring loaded slam shut valve with full bore body |
| HON 711 | Axial flow shut-off valve for large gate station duties |
| HON HSV086 | Pilot-operated globe shut-off valve for higher pressure ratings |
| HON 370 | Direct acting regulator with an optional integrated shut-off valve |
7. Common Spare Parts
| Spare part | Description |
|---|---|
| Seat and seal set | Matched to the single inline orifice; refer to the official parts list |
| Torsion spring | Spring matched to the trip setting range |
| Position indicator lens | Replacement cover for the enclosed colour indicator |
| Pilot line fittings | Matched to the external outlet sensing connection |
8. Accessories
| Accessory | Description |
|---|---|
| Remote position indication | Reports shut-off status to the station control system |
| Underpressure trip module | Extends the valve to combined overpressure and underpressure protection |
| Noise or weather cover | For exposed installations where offered; Ordering code per the official datasheet; verify with the manufacturer |
| Flange gasket set | Matched to the flange specified on the official data sheet |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文
ENGLISH