Home » Products » Honeywell
Honeywell Elster Jeavons S100 Slam Shut Valve DN50-100 Full Bore
Honeywell Elster Jeavons S100 Slam Shut Valve DN50-100 Full Bore
Honeywell Elster Jeavons S100 Slam Shut Valve DN50-100 Full Bore

Honeywell Elster Jeavons S100 Slam Shut Valve DN50-100 Full Bore

Details

1. Product Overview

The Elster Jeavons S100 is a spring loaded slam shut valve of the Series 100 type, installed upstream of a pressure regulator to provide overpressure protection. It is a purely mechanical device that does not need an external power or air supply.

Official literature lists DN50, DN80 and DN100 (2 in, 3 in and 4 in), a maximum inlet pressure of 19 bar (275 psig) and a maximum trip pressure of 6 bar (87 psig). The full bore design gives a low pressure drop. A local position indicator, manual reset and an internal automatic balancing valve are standard, with a remote indication microswitch offered as an option.

This page is a selection overview. Published figures are from the official data sheet; refer to the official datasheet; verify with the manufacturer.

Above: product appearance / manufacturer literature image.

2. Technical Description

Design: Spring loaded, pressure driven slam shut mechanism; full bore body with low pressure drop.

Size range: DN50, DN80 and DN100 (2 in, 3 in and 4 in).

Connections: Flange BS EN 1092-2 NP16; external sensing line Rc 1/4.

Pressure: Maximum inlet pressure 19 bar (275 psig); maximum trip pressure 6 bar (87 psig).

Operation: Sensing line connected to the regulator outlet; on overpressure the valve closes by impact action; manual reset after the fault is cleared.

Construction and approvals: Ductile iron body, stainless steel seat, aluminium alloy actuator and NBR elastomers; BS EN 14382, BGES/V9, DIN 3381, PED 2014/68/EU (CE Category IV) and UKCA.

Source: Honeywell official product pages (process.honeywell.com, honeywell.com.cn) and official data sheets / Bulletins; official product page https://process.honeywell.com/us/en/products/utilities/gas/gas-regulators/safety-devices/s100-slamshut-valve; official data sheet S1002EN, 06, 01/17 (Elster Jeavons S100 Slam Shut Valve)

3. Main Technical Specifications

ParameterSpecification / Description
Product typeSpring loaded slam shut valve
Series / modelElster Jeavons S100, Series 100
Size rangeDN50, DN80, DN100 (2 in, 3 in, 4 in)
Max inlet pressure19 bar (275 psig)
Max trip pressure6 bar (87 psig)
ConnectionFlange BS EN 1092-2 NP16; pilot line Rc 1/4 external sensing
MediumNatural gas, LPG and manufactured gas
InstallationHorizontal or vertical mounting
OperationPressure driven slam shut action; manual reset; internal automatic balancing valve
MaterialsDuctile iron body; stainless steel seat; aluminium alloy actuator; NBR diaphragm, disc and O-rings; carbon steel load spring
Temperature range-20 C to +60 C
ApprovalsBS EN 14382, BGES/V9, DIN 3381, PED 2014/68/EU (CE Category IV), UKCA
Other detailsrefer to the official datasheet; verify with the manufacturer
Source: Honeywell official product pages (process.honeywell.com, honeywell.com.cn) and official data sheets / Bulletins; official product page https://process.honeywell.com/us/en/products/utilities/gas/gas-regulators/safety-devices/s100-slamshut-valve; official data sheet S1002EN, 06, 01/17

4. Selection Guide

Selection sequence: Duty definition -> Size and connection -> Pressure check -> Sensing line -> Indication -> Verification.

StepItemKey point
1Duty definitionConfirm an upstream overpressure protection duty for a pressure regulator
2Size and connectionCheck DN50, DN80 or DN100 and the BS EN 1092-2 NP16 flange
3Pressure checkConfirm inlet pressure within 19 bar and required trip pressure within 6 bar
4Sensing lineConnect the Rc 1/4 external pilot line to the regulator outlet
5IndicationSpecify local indication and the remote microswitch where the station requires it
6VerificationConfirm the final configuration on the official data sheet; refer to the official datasheet; verify with the manufacturer

Boundary: For low and medium pressure commercial and industrial stations needing a full bore, low pressure drop, purely mechanical shut-off valve. Final data are per the official datasheet; refer to the official datasheet; verify with the manufacturer.

Source: Honeywell official product pages (process.honeywell.com, honeywell.com.cn) and official data sheets / Bulletins; official product page https://process.honeywell.com/us/en/products/utilities/gas/gas-regulators/safety-devices/s100-slamshut-valve; official data sheet S1002EN, 06, 01/17

5. Complete Model Enumeration

ModelFamily / functionKey specification
HON 711Axial flow safety shut-off valveDN25-400; overpressure and underpressure shut-off; DIN EN 14382
HON HSV086Pilot-operated globe safety shut-off valveDN25-500; ANSI 150-1500; accuracy class AC1; response under 1 s
Elster Jeavons S100Spring loaded slam shut valveDN50-100; 19 bar inlet; full bore; BS EN 14382
HON 305Self-operated safety shut-off valveDN50-200; up to 19 bar; single inline orifice
HON 512Axial flow pilot pressure regulatorDN25-300; outlet 0.3-90 bar; AC1 / SG5
HON R100Globe pilot high pressure regulatorDN25-400; high differential; optional cage silencer
HON R100NGGlobe pilot high pressure regulatorDN25-200; HON P095NG pilot; fail-closed or fail-open
HON R-50Dome loaded high pressure regulatorANSI 1500 design; accuracy within 1 percent
HON Elster AFVAxial flow valve for multi-purpose useDN50-300; ANSI 300 / 600; reversible sleeve
Elster Jeavons J123Spring loaded direct acting regulator2 in to 4 in; 4 bar inlet; outlet up to 350 mbar
Elster Jeavons J123HPHigh outlet spring loaded regulator2 in and 3 in; 4 bar inlet; outlet around 1 bar
HON 530Electric flow and pressure control valveDN50-500; equal percentage and linear; AC1
HON C210SGlobe flow control valveDN50-400; noise reduction up to 40 dB(A); electric or pneumatic
HON 274Lever spring loaded regulator with integrated SSV1-1/4 to 2 in thread, DN50 flange; outlet 15-420 mbar
HON 370Spring loaded direct acting regulatorDN25-150; 20 bar; outlet 20 mbar-4 bar
HON 372Pilot-operated regulator with integrated SSVDN25-150; outlet 10 mbar-15 bar; AC1 to AC10
HON 402Pilot-operated regulating and shut-off valveDN25-100; inlet up to 50 bar; outlet 20 mbar-40 bar

6. Related Models

Related modelDescription
Elster Jeavons J123Spring loaded distribution regulator commonly protected by the S100
HON 305Self-operated shut-off valve for an alternative mechanical protection duty
HON 370Direct acting regulator with integrated overpressure protection
HON 274Small flow regulator available with an integrated shut-off valve

7. Common Spare Parts

Spare partDescription
Seat and disc setStainless steel seat and NBR disc matched to the orifice
DiaphragmNBR diaphragm matched to the original actuator
Load springCarbon steel spring matched to the trip pressure range
Remote indication microswitchReplacement switch for the optional position feedback

8. Accessories

AccessoryDescription
Remote indication microswitchProvides open or closed position feedback
External sensing line kitRc 1/4 pilot line to the regulator outlet
Wall or line mounting bracketMatched to horizontal or vertical installation
Flange gasket setMatched to the BS EN 1092-2 NP16 connection

9. Disclaimer

The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources & Contact

Source: Honeywell official product pages (process.honeywell.com, honeywell.com.cn) and official data sheets / Bulletins; official data sheet S1002EN, 06, 01/17 (Elster Jeavons S100 Slam Shut Valve).

We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area