1. Product Overview
The Elster Jeavons S100 is a spring loaded slam shut valve of the Series 100 type, installed upstream of a pressure regulator to provide overpressure protection. It is a purely mechanical device that does not need an external power or air supply.
Official literature lists DN50, DN80 and DN100 (2 in, 3 in and 4 in), a maximum inlet pressure of 19 bar (275 psig) and a maximum trip pressure of 6 bar (87 psig). The full bore design gives a low pressure drop. A local position indicator, manual reset and an internal automatic balancing valve are standard, with a remote indication microswitch offered as an option.
This page is a selection overview. Published figures are from the official data sheet; refer to the official datasheet; verify with the manufacturer.



2. Technical Description
Design: Spring loaded, pressure driven slam shut mechanism; full bore body with low pressure drop.
Size range: DN50, DN80 and DN100 (2 in, 3 in and 4 in).
Connections: Flange BS EN 1092-2 NP16; external sensing line Rc 1/4.
Pressure: Maximum inlet pressure 19 bar (275 psig); maximum trip pressure 6 bar (87 psig).
Operation: Sensing line connected to the regulator outlet; on overpressure the valve closes by impact action; manual reset after the fault is cleared.
Construction and approvals: Ductile iron body, stainless steel seat, aluminium alloy actuator and NBR elastomers; BS EN 14382, BGES/V9, DIN 3381, PED 2014/68/EU (CE Category IV) and UKCA.
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Product type | Spring loaded slam shut valve |
| Series / model | Elster Jeavons S100, Series 100 |
| Size range | DN50, DN80, DN100 (2 in, 3 in, 4 in) |
| Max inlet pressure | 19 bar (275 psig) |
| Max trip pressure | 6 bar (87 psig) |
| Connection | Flange BS EN 1092-2 NP16; pilot line Rc 1/4 external sensing |
| Medium | Natural gas, LPG and manufactured gas |
| Installation | Horizontal or vertical mounting |
| Operation | Pressure driven slam shut action; manual reset; internal automatic balancing valve |
| Materials | Ductile iron body; stainless steel seat; aluminium alloy actuator; NBR diaphragm, disc and O-rings; carbon steel load spring |
| Temperature range | -20 C to +60 C |
| Approvals | BS EN 14382, BGES/V9, DIN 3381, PED 2014/68/EU (CE Category IV), UKCA |
| Other details | refer to the official datasheet; verify with the manufacturer |
4. Selection Guide
Selection sequence: Duty definition -> Size and connection -> Pressure check -> Sensing line -> Indication -> Verification.
| Step | Item | Key point |
|---|---|---|
| 1 | Duty definition | Confirm an upstream overpressure protection duty for a pressure regulator |
| 2 | Size and connection | Check DN50, DN80 or DN100 and the BS EN 1092-2 NP16 flange |
| 3 | Pressure check | Confirm inlet pressure within 19 bar and required trip pressure within 6 bar |
| 4 | Sensing line | Connect the Rc 1/4 external pilot line to the regulator outlet |
| 5 | Indication | Specify local indication and the remote microswitch where the station requires it |
| 6 | Verification | Confirm the final configuration on the official data sheet; refer to the official datasheet; verify with the manufacturer |
Boundary: For low and medium pressure commercial and industrial stations needing a full bore, low pressure drop, purely mechanical shut-off valve. Final data are per the official datasheet; refer to the official datasheet; verify with the manufacturer.
5. Complete Model Enumeration
| Model | Family / function | Key specification |
|---|---|---|
| HON 711 | Axial flow safety shut-off valve | DN25-400; overpressure and underpressure shut-off; DIN EN 14382 |
| HON HSV086 | Pilot-operated globe safety shut-off valve | DN25-500; ANSI 150-1500; accuracy class AC1; response under 1 s |
| Elster Jeavons S100 | Spring loaded slam shut valve | DN50-100; 19 bar inlet; full bore; BS EN 14382 |
| HON 305 | Self-operated safety shut-off valve | DN50-200; up to 19 bar; single inline orifice |
| HON 512 | Axial flow pilot pressure regulator | DN25-300; outlet 0.3-90 bar; AC1 / SG5 |
| HON R100 | Globe pilot high pressure regulator | DN25-400; high differential; optional cage silencer |
| HON R100NG | Globe pilot high pressure regulator | DN25-200; HON P095NG pilot; fail-closed or fail-open |
| HON R-50 | Dome loaded high pressure regulator | ANSI 1500 design; accuracy within 1 percent |
| HON Elster AFV | Axial flow valve for multi-purpose use | DN50-300; ANSI 300 / 600; reversible sleeve |
| Elster Jeavons J123 | Spring loaded direct acting regulator | 2 in to 4 in; 4 bar inlet; outlet up to 350 mbar |
| Elster Jeavons J123HP | High outlet spring loaded regulator | 2 in and 3 in; 4 bar inlet; outlet around 1 bar |
| HON 530 | Electric flow and pressure control valve | DN50-500; equal percentage and linear; AC1 |
| HON C210S | Globe flow control valve | DN50-400; noise reduction up to 40 dB(A); electric or pneumatic |
| HON 274 | Lever spring loaded regulator with integrated SSV | 1-1/4 to 2 in thread, DN50 flange; outlet 15-420 mbar |
| HON 370 | Spring loaded direct acting regulator | DN25-150; 20 bar; outlet 20 mbar-4 bar |
| HON 372 | Pilot-operated regulator with integrated SSV | DN25-150; outlet 10 mbar-15 bar; AC1 to AC10 |
| HON 402 | Pilot-operated regulating and shut-off valve | DN25-100; inlet up to 50 bar; outlet 20 mbar-40 bar |
6. Related Models
| Related model | Description |
|---|---|
| Elster Jeavons J123 | Spring loaded distribution regulator commonly protected by the S100 |
| HON 305 | Self-operated shut-off valve for an alternative mechanical protection duty |
| HON 370 | Direct acting regulator with integrated overpressure protection |
| HON 274 | Small flow regulator available with an integrated shut-off valve |
7. Common Spare Parts
| Spare part | Description |
|---|---|
| Seat and disc set | Stainless steel seat and NBR disc matched to the orifice |
| Diaphragm | NBR diaphragm matched to the original actuator |
| Load spring | Carbon steel spring matched to the trip pressure range |
| Remote indication microswitch | Replacement switch for the optional position feedback |
8. Accessories
| Accessory | Description |
|---|---|
| Remote indication microswitch | Provides open or closed position feedback |
| External sensing line kit | Rc 1/4 pilot line to the regulator outlet |
| Wall or line mounting bracket | Matched to horizontal or vertical installation |
| Flange gasket set | Matched to the BS EN 1092-2 NP16 connection |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文
ENGLISH