Honeywell Elster 711 Safety Shut-off Valve DN25-400 for Gas
1. Product Overview
The Honeywell HON 711 is an axial flow safety shut-off valve (SSV) used for overpressure and underpressure protection at gas pressure regulating stations. The design is also supplied as HON 711 S2 within the same family.
Official literature lists sizes from DN25 to DN400, flange connections to DIN PN25 / PN40 and ANSI 300 / 600 / 900, and a maximum operating pressure that depends on the flange pressure class. The axial flow body gives a low pressure drop and permits the internals to be changed in line. Manual reset is standard, with remote position indication and remote forced shut-off offered as options.
This page is a selection overview. Where official sources give different figures for the same item, both are shown side by side; final data are per the official datasheet and refer to the official datasheet; verify with the manufacturer.



2. Technical Description
Design: Axial flow safety shut-off valve; low pressure drop; internals replaceable in line.
Size range: DN25, 50, 80, 100, 150, 200, 250, 300 and 400.
Connections: DIN flanges PN25 and PN40; ANSI 300, 600 and 900 in RF or RTJ execution.
Pressure: PSmax 150 bar depending on flange class; the English product page states up to 100 bar, with the ANSI 900 RTJ version available up to 130 bar on request.
Trip setting: Overpressure shut-off 0.05-90 bar and underpressure shut-off 0.01-90 bar; response time 0.5 s or less in the Chinese sample, and 0.1-0.3 s on the English product page depending on valve size and control device.
Materials and approvals: Body A352 LCC or G20Mn5 QT; NBR O-rings; DIN EN 14382 (DIN 3381), CE (PED), DVGW, GOST and SIL3 per IEC 61508.
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Product type | Axial flow safety shut-off valve (SSV) |
| Series / model | Honeywell Elster HON 711; family includes HON 711 S2 |
| Size range | DN25, 50, 80, 100, 150, 200, 250, 300, 400 |
| Max operating pressure | PSmax 150 bar depending on flange class; English page up to 100 bar, ANSI 900 RTJ 130 bar on request |
| Pressure class / connection | DIN PN25, PN40; ANSI 300, 600, 900; RF / RTJ |
| Medium | Natural gas (DVGW G260) and other non-corrosive gases; consult the manufacturer for other gases |
| Overpressure trip range | 0.05-90 bar |
| Underpressure trip range | 0.01-90 bar |
| Response time | 0.5 s or less; English page 0.1-0.3 s depending on size and control device |
| Body / internals material | A352 LCC / G20Mn5 QT body; shut-off device in cast aluminium; internals in aluminium, stainless steel, copper and steel; NBR O-rings |
| Temperature range | Class 2, -20 C to +60 C; other ranges on request |
| Design standard / approvals | DIN EN 14382 (DIN 3381); CE (PED), DVGW, GOST, SIL3 per IEC 61508 |
| Other details | refer to the official datasheet; verify with the manufacturer |
4. Selection Guide
Selection sequence: Duty definition -> Size and connection -> Pressure check -> Trip setting -> Function options -> Verification.
| Step | Item | Key point |
|---|---|---|
| 1 | Duty definition | Confirm overpressure, underpressure or combined shut-off protection at the regulating station |
| 2 | Size and connection | Check DN25 to DN400 and the DIN or ANSI flange class against the official data sheet |
| 3 | Pressure check | Confirm the inlet pressure against the PSmax figure for the selected flange class |
| 4 | Trip setting | Set the overpressure 0.05-90 bar and underpressure 0.01-90 bar ranges to the required protection points |
| 5 | Function options | Specify manual reset plus remote indication and remote forced shut-off where the station requires them |
| 6 | Verification | Confirm the final configuration on the official data sheet; refer to the official datasheet; verify with the manufacturer |
Boundary: For gate stations and plant inlets needing a low pressure drop, in-line serviceable axial shut-off valve. Sizes above DN150 are listed by Honeywell under a separate HON 711 DN 200 thru 300 product page. Final data are per the official datasheet; refer to the official datasheet; verify with the manufacturer.
5. Complete Model Enumeration
| Model | Family / function | Key specification |
|---|---|---|
| HON 711 | Axial flow safety shut-off valve | DN25-400; overpressure and underpressure shut-off; DIN EN 14382 |
| HON HSV086 | Pilot-operated globe safety shut-off valve | DN25-500; ANSI 150-1500; accuracy class AC1; response under 1 s |
| Elster Jeavons S100 | Spring loaded slam shut valve | DN50-100; 19 bar inlet; full bore; BS EN 14382 |
| HON 305 | Self-operated safety shut-off valve | DN50-200; up to 19 bar; single inline orifice |
| HON 512 | Axial flow pilot pressure regulator | DN25-300; outlet 0.3-90 bar; AC1 / SG5 |
| HON R100 | Globe pilot high pressure regulator | DN25-400; high differential; optional cage silencer |
| HON R100NG | Globe pilot high pressure regulator | DN25-200; HON P095NG pilot; fail-closed or fail-open |
| HON R-50 | Dome loaded high pressure regulator | ANSI 1500 design; accuracy within 1 percent |
| HON Elster AFV | Axial flow valve for multi-purpose use | DN50-300; ANSI 300 / 600; reversible sleeve |
| Elster Jeavons J123 | Spring loaded direct acting regulator | 2 in to 4 in; 4 bar inlet; outlet up to 350 mbar |
| Elster Jeavons J123HP | High outlet spring loaded regulator | 2 in and 3 in; 4 bar inlet; outlet around 1 bar |
| HON 530 | Electric flow and pressure control valve | DN50-500; equal percentage and linear; AC1 |
| HON C210S | Globe flow control valve | DN50-400; noise reduction up to 40 dB(A); electric or pneumatic |
| HON 274 | Lever spring loaded regulator with integrated SSV | 1-1/4 to 2 in thread, DN50 flange; outlet 15-420 mbar |
| HON 370 | Spring loaded direct acting regulator | DN25-150; 20 bar; outlet 20 mbar-4 bar |
| HON 372 | Pilot-operated regulator with integrated SSV | DN25-150; outlet 10 mbar-15 bar; AC1 to AC10 |
| HON 402 | Pilot-operated regulating and shut-off valve | DN25-100; inlet up to 50 bar; outlet 20 mbar-40 bar |
6. Related Models
| Related model | Description |
|---|---|
| HON 711 S2 | Second-stage member of the HON 711 safety shut-off family |
| HON HSV086 | Pilot-operated globe shut-off valve for higher inlet pressure duties |
| HON 305 | Self-operated shut-off valve where no external power source is available |
| HON 512 | Axial flow pressure regulator used upstream of the shut-off valve |
7. Common Spare Parts
| Spare part | Description |
|---|---|
| Internals / trim set | Matched to the axial flow HON 711 body; refer to the official parts list |
| Closing spring | Spring steel spring matched to the trip setting range |
| O-ring set | NBR seals matched to the fitted control device |
| Control device diaphragm | Matched to the overpressure or underpressure control unit fitted |
8. Accessories
| Accessory | Description |
|---|---|
| Remote position indication | Reports valve open or closed status to the station control system |
| Remote forced shut-off | Allows an emergency trip signal from a remote location |
| Manual release extension | For access where the valve is installed in a pit or cabinet |
| Mounting kit | Matched to the valve body and flange class; Ordering code per the official datasheet; verify with the manufacturer |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文
ENGLISH