1. Product Overview

The CCS 675GS is a low-range general-purpose switch with a large diaphragm for inches-of-water settings. The product literature positions the 675GS in the gage family, while the official data sheet labels the set point table as differential pressure; confirm the pressure type definition against the official data sheet.

The set point range is 0.2-31 inH2O (0.5-77.2 mbar / 0.05-7.72 kPa), split into five rising and falling bands. The switch uses a 1/4-18 NPT aluminum pressure connection, polyimide diaphragm and Buna N O-ring, with SPDT contact and NEMA 4,13 / IP65 protection.

This page is a selection overview. The stated ranges are published figures; refer to the official datasheet; verify with the manufacturer.

Above: product appearance / manufacturer literature image.

2. Technical Description

Pressure type: Gage family positioning; the data sheet set point table is labelled differential pressure.

Set point range: 0.2-31 inH2O (0.5-77.2 mbar / 0.05-7.72 kPa).

Set point bands (675GS*8001-8005, rising): 2-6.9, 7-12.9, 13-18.9, 19-24.9 and 25-31 inH2O.

Falling bands: 0.2-5.1, 5.5-11.4, 11-16.9, 16.5-22.4 and 22-28 inH2O.

Electrical: SPDT; 125 VAC 50/60 Hz 11 A; 250 VAC 50/60 Hz 11 A; 30 VDC 5 A; 125 VDC 0.5 A.

Construction: 1/4-18 NPT aluminum port, polyimide diaphragm, Buna N O-ring, -40 to 186 deg F, NEMA 4,13 / IP65.

Source: CCS official product pages (ccsdualsnap.com and custom-control-sensors.com) and official data sheets; official data sheet 675GS* (675GS-Non-Hazardous-Series-181005.pdf); official industrial pressure switches page http://ccsdualsnap.com/products/industrial-pressure-switches/

3. Main Technical Specifications

ParameterSpecification / Description
Product typeLow-range general-purpose pressure switch
Series / modelCCS 675GS
Pressure typeGage family; data sheet labels the set points as differential pressure
Pressure type definitionrefer to the official datasheet; verify with the manufacturer
Set point range0.2-31 inH2O (0.5-77.2 mbar / 0.05-7.72 kPa)
Set point bands (rising, 8001-8005)2-6.9; 7-12.9; 13-18.9; 19-24.9; 25-31 inH2O
Set point bands (falling, 8001-8005)0.2-5.1; 5.5-11.4; 11-16.9; 16.5-22.4; 22-28 inH2O
Electrical arrangementSPDT
Electrical rating125 VAC 11 A; 250 VAC 11 A; 30 VDC 5 A; 125 VDC 0.5 A (AC at 50/60 Hz)
Pressure connection1/4-18 NPT, aluminum
Diaphragm / O-ringPolyimide diaphragm; Buna N O-ring
Ambient temperature-40 to 186 deg F (-40 to 86 deg C)
Approvals / protectionNEMA 4,13 / IP65
OptionsViton O-ring (option A); gold contacts 7008; 2 m leads 7054; 18 in Teflon leads 7076
Source: CCS official product pages (ccsdualsnap.com and custom-control-sensors.com) and official data sheets; official data sheet 675GS* (675GS-Non-Hazardous-Series-181005.pdf); official industrial pressure switches page http://ccsdualsnap.com/products/industrial-pressure-switches/

4. Selection Guide

Selection sequence: Pressure type -> Set point band -> Port interface -> Electrical duty -> Environment -> Verification.

StepItemKey point
1Pressure typeConfirm the required pressure type definition against the official data sheet
2Set point bandChoose a rising band from 8001-8005 and its falling counterpart
3Port interfaceAllow for a 1/4-18 NPT aluminum pressure connection
4Electrical dutyConfirm SPDT switching against the AC and DC ratings on the data sheet
5EnvironmentCheck NEMA 4,13 / IP65 protection and -40 to 186 deg F ambient
6VerificationConfirm the selected suffix and options against the official data sheet; refer to the official datasheet; verify with the manufacturer

Boundary: Use this switch for low-range inches-of-water duty in non-hazardous locations. Pressure type definition, set point band and options are per the official data sheet; refer to the official datasheet; verify with the manufacturer.

Source: CCS official product pages (ccsdualsnap.com and custom-control-sensors.com) and official data sheets; official data sheet 675GS* (675GS-Non-Hazardous-Series-181005.pdf); official industrial pressure switches page http://ccsdualsnap.com/products/industrial-pressure-switches/

5. Complete Model Enumeration

Model / variantPressure typeKey feature
604 familyGage / differential / vacuum / pistonGeneral industrial all-aluminum switch with integral junction box
605 familyGage / differential / vacuum / pistonWeather-resistant switch with downward-facing electrical port
611VVacuumCompact switch based on the 6900 platform, male 1/4 in NPT
6214GBGageTire curing press switch with dual ports and a debris clean-out port
646GEGageHazardous-location heavy-duty all-aluminum switch, female 1/4 in NPT
646PEGage (piston)Hazardous-location piston switch for hydraulic fluid duty
646VEVacuumHazardous-location vacuum switch; 646GV*E* gives vacuum-to-gage cross setting
675DSDifferentialLow-range differential switch with large diaphragm for inches-of-water settings
675GSGage / differentialLow-range switch for inches-of-water settings, NEMA 4,13 / IP65
6900GGageGeneral-purpose all-aluminum switch with a wide set point range
6900PGage (piston)General-purpose piston-port switch for hydraulic fluid duty

6. Related Models

Related modelDescription
CCS 675DSLow-range differential switch with large diaphragm
CCS 604GGeneral industrial gage switch with integral junction box
CCS 605GWeather-resistant gage switch with NEMA 4X / IP66
CCS 611GCompact gage switch based on the 6900 platform

7. Common Spare Parts

Spare partDescription
DiaphragmPolyimide type matched to the original 675GS range; refer to the official spare parts list
O-ringBuna N or Viton type selected to the fitted port and medium
Switch contact blockSPDT block matched to the fitted electrical rating
Enclosure coverReplacement cover for the 675 enclosure

8. Accessories

AccessoryDescription
Viton O-ring optionOption A for compatibility with the process medium
Gold contact optionOption 7008 per the official data sheet
Lead wire option7054 2 m leads or 7076 18 in Teflon leads
Panel mounting kitFor panel or equipment installation of the 675 enclosure

9. Disclaimer

The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources & Contact

Source: CCS official product pages (ccsdualsnap.com and custom-control-sensors.com) and official data sheets; official data sheet 675GS* (675GS-Non-Hazardous-Series-181005.pdf); official industrial pressure switches page http://ccsdualsnap.com/products/industrial-pressure-switches/.

We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area