Home » Products » CCS
CCS 675DS Low Range Differential Pressure Switch Large Diaphragm SPDT
CCS 675DS Low Range Differential Pressure Switch Large Diaphragm SPDT
CCS 675DS Low Range Differential Pressure Switch Large Diaphragm SPDT

CCS 675DS Low Range Differential Pressure Switch Large Diaphragm SPDT

Details

1. Product Overview

The CCS 675DS is a low-range general-purpose differential pressure switch built around a large diaphragm for settings in the inches-of-water range. It uses the Dual-Snap Belleville disc spring and is intended for non-hazardous industrial service.

The large diaphragm supports stable switching at very low differential pressures, and the disc spring element resists vibration and shock. Detailed values for range, ports, electrical duty, housing, contacts, temperature and approvals are given in the official data sheet.

This page is a selection overview. The stated ranges are published figures; refer to the official datasheet; verify with the manufacturer.

Above: product appearance / manufacturer literature image.

2. Technical Description

Pressure type: Differential pressure.

Range characteristic: Low range, inches-of-water settings with a large diaphragm design.

Sensing: Dual-Snap Belleville disc spring with high vibration and shock resistance.

Service: Non-hazardous locations including power generation, rail vehicles, fluid management, process manufacturing, water and utility treatment, refining and safety systems.

Family reference (675GS data sheet): 0.2-31 inH2O (0.5-77.2 mbar), 1/4-18 NPT aluminum port, polyimide diaphragm, Buna N O-ring, -40 to 186 deg F, NEMA 4,13 / IP65.

Detailed 675DS values: refer to the official datasheet; verify with the manufacturer.

Source: CCS official product pages (ccsdualsnap.com and custom-control-sensors.com) and official data sheets; official product page https://custom-control-sensors.com/industrial-pressure-switches/675ds-series-differential-switches; family data sheet 675GS (675GS-Non-Hazardous-Series-181005.pdf)

3. Main Technical Specifications

ParameterSpecification / Description
Product typeLow-range differential pressure switch
Series / modelCCS 675DS
Pressure typeDifferential pressure
Set point rangerefer to the official datasheet; verify with the manufacturer; low-range inches-of-water class on the product page
Diaphragm designLarge diaphragm
Sensing principleDual-Snap Belleville disc spring
Pressure connectionrefer to the official datasheet; verify with the manufacturer; 675GS family reference: 1/4-18 NPT, aluminum
Electrical arrangementrefer to the official datasheet; verify with the manufacturer; 675GS family reference: SPDT
Voltage and current ratingrefer to the official datasheet; verify with the manufacturer
Housing materialrefer to the official datasheet; verify with the manufacturer
Ambient temperaturerefer to the official datasheet; verify with the manufacturer; 675GS family reference: -40 to 186 deg F
Approvals / protectionrefer to the official datasheet; verify with the manufacturer; 675GS family reference: NEMA 4,13 / IP65
Wetted partsrefer to the official datasheet; verify with the manufacturer; 675GS family reference: polyimide diaphragm, Buna N O-ring
Source: CCS official product pages (ccsdualsnap.com and custom-control-sensors.com) and official data sheets; official product page https://custom-control-sensors.com/industrial-pressure-switches/675ds-series-differential-switches; family data sheet 675GS (675GS-Non-Hazardous-Series-181005.pdf)

4. Selection Guide

Selection sequence: Pressure type -> Set point band -> Diaphragm -> Port interface -> Electrical duty -> Verification.

StepItemKey point
1Pressure typeConfirm a low differential pressure measurement is required
2Set point bandCheck the inches-of-water setting against the official 675DS data sheet
3DiaphragmConfirm the large-diaphragm design suits the required low range
4Port interfaceConfirm the pressure port and connection material against the official data sheet
5Electrical dutyConfirm contact form and electrical rating against the official data sheet
6VerificationConfirm the final configuration against the official data sheet; refer to the official datasheet; verify with the manufacturer

Boundary: This switch is for low-range differential duty in non-hazardous locations. Range, ports, wetted parts and electrical ratings are per the official data sheet; refer to the official datasheet; verify with the manufacturer.

Source: CCS official product pages (ccsdualsnap.com and custom-control-sensors.com) and official data sheets; official product page https://custom-control-sensors.com/industrial-pressure-switches/675ds-series-differential-switches; family data sheet 675GS (675GS-Non-Hazardous-Series-181005.pdf)

5. Complete Model Enumeration

Model / variantPressure typeKey feature
604 familyGage / differential / vacuum / pistonGeneral industrial all-aluminum switch with integral junction box
605 familyGage / differential / vacuum / pistonWeather-resistant switch with downward-facing electrical port
611VVacuumCompact switch based on the 6900 platform, male 1/4 in NPT
6214GBGageTire curing press switch with dual ports and a debris clean-out port
646GEGageHazardous-location heavy-duty all-aluminum switch, female 1/4 in NPT
646PEGage (piston)Hazardous-location piston switch for hydraulic fluid duty
646VEVacuumHazardous-location vacuum switch; 646GV*E* gives vacuum-to-gage cross setting
675DSDifferentialLow-range differential switch with large diaphragm for inches-of-water settings
675GSGage / differentialLow-range switch for inches-of-water settings, NEMA 4,13 / IP65
6900GGageGeneral-purpose all-aluminum switch with a wide set point range
6900PGage (piston)General-purpose piston-port switch for hydraulic fluid duty

6. Related Models

Related modelDescription
CCS 675GSLow-range switch for inches-of-water settings
CCS 604DGeneral industrial differential switch with integral junction box
CCS 605DWeather-resistant differential switch
CCS 6900GGeneral-purpose all-aluminum gage switch

7. Common Spare Parts

Spare partDescription
DiaphragmLarge diaphragm matched to the original 675DS range; refer to the official spare parts list
O-ringSelected to the fitted port configuration and medium
Switch contact blockContact block matched to the fitted electrical rating
Enclosure coverReplacement cover for the 675 enclosure

8. Accessories

AccessoryDescription
Panel mounting kitFor panel or equipment installation of the 675 enclosure
Conduit adapterMatched to the electrical port on the official data sheet
Diaphragm / O-ring optionSelected to the medium and temperature range
Contact material optionMatched to the duty per the official data sheet

9. Disclaimer

The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources & Contact

Source: CCS official product pages (ccsdualsnap.com and custom-control-sensors.com) and official data sheets; official product page https://custom-control-sensors.com/industrial-pressure-switches/675ds-series-differential-switches; family data sheet 675GS (675GS-Non-Hazardous-Series-181005.pdf).

We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area