Home » Products » CCS
CCS 646VE Hazardous Location Vacuum Pressure Switch Female 1/4 NPT Aluminum
CCS 646VE Hazardous Location Vacuum Pressure Switch Female 1/4 NPT Aluminum
CCS 646VE Hazardous Location Vacuum Pressure Switch Female 1/4 NPT Aluminum

CCS 646VE Hazardous Location Vacuum Pressure Switch Female 1/4 NPT Aluminum

Details

1. Product Overview

The CCS 646VE is the vacuum version of the 646 family of heavy-duty all-aluminum switches for hazardous locations. It uses the Dual-Snap Belleville disc spring and is suited to very low pressure and vacuum-to-pressure applications.

The official data sheet gives a vacuum set point range of 1-28.5 inHg (25-724 mmHg) for the 646V*E* diaphragm sensor, while the 646GV*E* cross type covers 20 inHg vacuum to 12 PSIG. Contact form and electrical ratings depend on the ordered suffix, including the DPDT 646VEM variant.

This page is a selection overview. The stated ranges are published figures; refer to the official datasheet; verify with the manufacturer.

Above: product appearance / manufacturer literature image.

2. Technical Description

Pressure type: Vacuum (negative pressure); the 646GV*E* cross type provides vacuum-to-gage control.

Set point range: 1-28.5 inHg (25-724 mmHg); cross type 20 inHg vacuum to 12 PSIG.

Reference values (646VEM): Rising 1.7-14 PSIG and falling 0.5-12.8 PSIG as labelled on the product page.

Electrical: 646VEM DPDT variant 0-250 VAC / 251-480 VAC, 0.5-5 A; the base 646VE SPDT rating is per the data sheet.

Pressure connection: Female 1/4 in NPT, aluminum; electrical connection male 1/2 in NPT.

Protection: CE Mark, Dual Seal ANSI/ISA-12.27.01, NACE MR0175 / ISO 15156, NEMA 4/7/9/13 / IP66, CRN, UL and CSA listed.

Source: CCS official product pages (ccsdualsnap.com and custom-control-sensors.com) and official data sheets; official product page https://www.ccsdualsnap.com/product/646vem; official data sheet 646V*E* / 646GV*E* (646VE-GVE_2012-09-20.pdf, Form 830G)

3. Main Technical Specifications

ParameterSpecification / Description
Product typeHazardous-location vacuum pressure switch
Series / modelCCS 646VE
Pressure typeVacuum (negative pressure); 646GV*E* cross type for vacuum-to-gage
Set point range1-28.5 inHg (25-724 mmHg); cross type 20 inHg vacuum to 12 PSIG
Reference values (646VEM variant)Rising 1.7-14 PSIG; falling 0.5-12.8 PSIG as labelled
Contact formSPDT as stated in the listing; DPDT on the 646VEM variant; refer to the official datasheet; verify with the manufacturer
Electrical rating (646VEM)0-250 VAC / 251-480 VAC, 0.5-5 A
Electrical rating (base SPDT)refer to the official datasheet; verify with the manufacturer
Pressure connectionFemale 1/4 in NPT, aluminum (family specification)
Electrical connectionMale 1/2 in NPT (family specification)
Housing materialAluminum (all-aluminum construction)
Ambient temperature-40 to 186 deg F (-40 to 86 deg C)
Approvals / protectionCE Mark, Dual Seal ANSI/ISA-12.27.01, NACE MR0175 / ISO 15156, NEMA 4/7/9/13 / IP66, CRN, UL and CSA listed
Source: CCS official product pages (ccsdualsnap.com and custom-control-sensors.com) and official data sheets; official product page https://www.ccsdualsnap.com/product/646vem; official data sheet 646V*E* / 646GV*E* (646VE-GVE_2012-09-20.pdf, Form 830G)

4. Selection Guide

Selection sequence: Location -> Pressure type -> Set point band -> Contact form -> Port interface -> Verification.

StepItemKey point
1LocationConfirm the hazardous location classification and the required approvals
2Pressure typeChoose vacuum or the 646GV*E* vacuum-to-gage cross type
3Set point bandMatch the 1-28.5 inHg vacuum range or the 20 inHg to 12 PSIG cross range
4Contact formConfirm SPDT or DPDT against the ordered suffix; refer to the official datasheet; verify with the manufacturer for the base rating
5Port interfaceAllow for female 1/4 in NPT pressure and male 1/2 in NPT electrical ports
6VerificationConfirm the final configuration against the official data sheet; refer to the official datasheet; verify with the manufacturer

Boundary: Use the 646 family for the stated hazardous-area conditions. Contact form, electrical rating and range are per the official data sheet; refer to the official datasheet; verify with the manufacturer.

Source: CCS official product pages (ccsdualsnap.com and custom-control-sensors.com) and official data sheets; official product page https://www.ccsdualsnap.com/product/646vem; official data sheet 646V*E* / 646GV*E* (646VE-GVE_2012-09-20.pdf, Form 830G)

5. Complete Model Enumeration

Model / variantPressure typeKey feature
604 familyGage / differential / vacuum / pistonGeneral industrial all-aluminum switch with integral junction box
605 familyGage / differential / vacuum / pistonWeather-resistant switch with downward-facing electrical port
611VVacuumCompact switch based on the 6900 platform, male 1/4 in NPT
6214GBGageTire curing press switch with dual ports and a debris clean-out port
646GEGageHazardous-location heavy-duty all-aluminum switch, female 1/4 in NPT
646PEGage (piston)Hazardous-location piston switch for hydraulic fluid duty
646VEVacuumHazardous-location vacuum switch; 646GV*E* gives vacuum-to-gage cross setting
675DSDifferentialLow-range differential switch with large diaphragm for inches-of-water settings
675GSGage / differentialLow-range switch for inches-of-water settings, NEMA 4,13 / IP65
6900GGageGeneral-purpose all-aluminum switch with a wide set point range
6900PGage (piston)General-purpose piston-port switch for hydraulic fluid duty

6. Related Models

Related modelDescription
CCS 646GEHazardous-location gage switch in the 646 family
CCS 646PEHazardous-location piston gage switch for hydraulic fluid
CCS 611VCompact vacuum switch based on the 6900 platform
CCS 604VGeneral industrial vacuum switch with a female 1/4 in NPT port

7. Common Spare Parts

Spare partDescription
DiaphragmMatched to the original 646VE range; refer to the official spare parts list
O-ringSelected to the fitted port configuration and medium
Switch contact blockSPDT or DPDT block matched to the ordered suffix
Enclosure coverReplacement cover for the all-aluminum hazardous-location body

8. Accessories

AccessoryDescription
Explosion-proof conduit adapterMatched to the male 1/2 in NPT electrical port
Cross-range option646GV*E* arrangement for vacuum-to-gage control
Contact material optionSilver or gold contacts per the official data sheet
Vacuum line adapterMatched to the female 1/4 in NPT pressure connection

9. Disclaimer

The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources & Contact

Source: CCS official product pages (ccsdualsnap.com and custom-control-sensors.com) and official data sheets; official product page https://www.ccsdualsnap.com/product/646vem; official data sheet 646V*E* / 646GV*E* (646VE-GVE_2012-09-20.pdf, Form 830G).

We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area