Home » Products » KROHNE
KROHNE POWERFLUX 5300 Full-Bore Wafer Electromagnetic Flowmeter DN15-300 Stainle
KROHNE POWERFLUX 5300 Full-Bore Wafer Electromagnetic Flowmeter DN15-300 Stainle
KROHNE POWERFLUX 5300 Full-Bore Wafer Electromagnetic Flowmeter DN15-300 Stainle

KROHNE POWERFLUX 5300 Full-Bore Wafer Electromagnetic Flowmeter DN15-300 Stainle

Details

1. Product Overview

The KROHNE POWERFLUX 5300 is the full-bore wafer-design meter in the OPTIFLUX 5000 ceramic platform. It uses a stainless steel housing and a ceramic measuring tube, and is installed between flanges for duties where low pressure loss and compact construction are useful.

The model is specified DN15 to DN300 with conductivity >= 1 uS/cm and temperature up to +180 deg C, offering 4-20 mA and HART outputs. It is applied in metering and process measurement where a wafer-type installation is preferred over a flanged flow tube.

This page is a selection overview. The figures shown are published range values; refer to the official datasheet; verify with the manufacturer.

Above: product appearance / manufacturer literature image.

2. Technical Description

Measuring principle: Faraday electromagnetic induction for conductive liquids.

Nominal bore: DN15 to DN300.

Construction: Full-bore wafer design with stainless steel housing.

Measuring tube: Ceramic, with no polymer liner.

Conductivity and temperature: >= 1 uS/cm; up to +180 deg C.

Outputs: 4-20 mA and HART.

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX 5000 / OPTIFLUX 5300 product page https://www.krohnechina.com/zh/products/flow-measurement/flowmeters/electromagnetic-flowmeters/optiflux-5300

3. Main Technical Specifications

ParameterSpecification / Description
Product typeFull-bore wafer electromagnetic flowmeter
Series / modelKROHNE POWERFLUX 5300
Measuring principleFaraday law of electromagnetic induction
Nominal boreDN15 to DN300
ConstructionWafer type, stainless steel housing
Measuring tubeCeramic, no polymer liner
Conductivity>= 1 uS/cm
Process temperatureUp to +180 deg C
Process pressurerefer to the official datasheet; verify with the manufacturer
Outputs4-20 mA, HART
InstallationBetween flanges; full-bore low-pressure-loss design
ApplicationWafer-type metering and process measurement
Accuracy and orderingrefer to the official datasheet; verify with the manufacturer; Ordering code per the official datasheet; verify with the manufacturer
Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX 5000 / OPTIFLUX 5300 product page https://www.krohnechina.com/zh/products/flow-measurement/flowmeters/electromagnetic-flowmeters/optiflux-5300

4. Selection Guide

Selection sequence: Installation check -> Conductivity check -> Bore sizing -> Ceramic tube -> Outputs -> Verification.

StepItemKey point
1Installation checkConfirm a wafer-type installation between existing flanges
2Conductivity checkVerify the medium meets >= 1 uS/cm
3Bore sizingChoose a bore from DN15 to DN300 for the line
4Ceramic tubeConfirm the ceramic tube and stainless steel housing suit the medium
5OutputsSelect 4-20 mA and HART for the control loop
6VerificationConfirm flange compatibility, ratings and ordering code with the official datasheet; Ordering code per the official datasheet; verify with the manufacturer

Boundary: Wafer dimensions and pressure ratings are configuration dependent; refer to the official datasheet; verify with the manufacturer.

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX 5000 / OPTIFLUX 5300 product page https://www.krohnechina.com/zh/products/flow-measurement/flowmeters/electromagnetic-flowmeters/optiflux-5300

5. Complete Model Enumeration

Model familyPositionDescription
OPTIFLUX 4000Chemical and processPTFE / PFA lined full-bore meters for corrosive and higher-temperature industrial media
OPTIFLUX 5000Custody-transfer meteringCeramic measuring-tube meters for small-bore high-accuracy and metering duties
OPTIFLUX 6000Hygienic processHygienic full-bore meters with PFA liner for food, beverage and pharmaceutical duties
BATCHFLUXBatching and fillingLow-power batching flowmeters for dosing and filling applications
OPTIPROBEInsertion, large pipeInsertion electromagnetic flowmeters for large water and wastewater pipes
DWM 2000Insertion, medium-large pipeInsertion electromagnetic flowmeter with stainless steel housing for water and process media

6. Related Models

Related modelDescription
KROHNE OPTIFLUX 5300Wide-range ceramic meter in the same platform
KROHNE OPTIFLUX 5100Ceramic metering meter with HART
KROHNE POWERFLUX 5030Small-bore ceramic meter for metering
KROHNE IFC 100Compact HART signal converter

7. Common Spare Parts

Spare partDescription
Ceramic measuring tubeMatched to the original nominal bore
Measuring electrodeSelected against the original sensor datasheet
IFC converter moduleReplacement with matching HART setup
Excitation coilReplacement matched to the sensor size
Seal and gasket setMatched to the original wafer assembly

8. Accessories

AccessoryDescription
IFC signal converterCompact, wall, field or panel version as required
HART communicatorFor configuration and diagnostics
Grounding ringFor dependable earthing of the tube
Flange gasket setMatched to the installed flange class
Remote mounting kitWhere the converter is installed away from the sensor

9. Disclaimer

The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources & Contact

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX 5000 / OPTIFLUX 5300 product page https://www.krohnechina.com/zh/products/flow-measurement/flowmeters/electromagnetic-flowmeters/optiflux-5300.

We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area