Home » Products » KROHNE
KROHNE OPTIFLUX 5300 Ceramic Electromagnetic Flowmeter DN15-300 Wide Range with
KROHNE OPTIFLUX 5300 Ceramic Electromagnetic Flowmeter DN15-300 Wide Range with
KROHNE OPTIFLUX 5300 Ceramic Electromagnetic Flowmeter DN15-300 Wide Range with

KROHNE OPTIFLUX 5300 Ceramic Electromagnetic Flowmeter DN15-300 Wide Range with

Details

1. Product Overview

The KROHNE OPTIFLUX 5300 is the wide-measuring-range member of the OPTIFLUX 5000 ceramic metering platform. It combines a ceramic measuring tube with a broad flow range, so a single meter can cover duties where the flow rate varies considerably.

The model is specified DN15 to DN300 with conductivity >= 1 uS/cm and temperature up to +180 deg C. Depending on the signal converter, outputs include 4-20 mA, HART, Modbus, FF and Profibus PA. It is used for wide-range metering and custody-transfer applications, with OIML R117 and MI-005 approvals by configuration.

This page is a selection overview. The figures shown are published range values; refer to the official datasheet; verify with the manufacturer.

Above: product appearance / manufacturer literature image.

2. Technical Description

Measuring principle: Faraday electromagnetic induction for conductive liquids.

Nominal bore: DN15 to DN300.

Measuring tube: Ceramic, with a wide measuring range.

Conductivity: >= 1 uS/cm.

Process temperature: Up to +180 deg C.

Outputs: 4-20 mA / HART / Modbus / FF / Profibus PA depending on converter.

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX 5000 / OPTIFLUX 5300 product page https://www.krohnechina.com/zh/products/flow-measurement/flowmeters/electromagnetic-flowmeters/optiflux-5300

3. Main Technical Specifications

ParameterSpecification / Description
Product typeWide-range ceramic electromagnetic flowmeter
Series / modelKROHNE OPTIFLUX 5300
Measuring principleFaraday law of electromagnetic induction
Nominal boreDN15 to DN300
Measuring tubeCeramic, wide measuring range
Conductivity>= 1 uS/cm
Process temperatureUp to +180 deg C
Process pressurerefer to the official datasheet; verify with the manufacturer
Outputs4-20 mA, HART, Modbus, FF, Profibus PA by converter
Metering approvalOIML R117 / MI-005 by configuration; refer to the official datasheet; verify with the manufacturer
Version optionsC compact / W wall remote / F field remote / R panel
ApplicationWide-range metering and custody-transfer measurement
Accuracy and orderingrefer to the official datasheet; verify with the manufacturer; Ordering code per the official datasheet; verify with the manufacturer
Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX 5000 / OPTIFLUX 5300 product page https://www.krohnechina.com/zh/products/flow-measurement/flowmeters/electromagnetic-flowmeters/optiflux-5300

4. Selection Guide

Selection sequence: Flow profile -> Conductivity check -> Bore sizing -> Ceramic tube -> Converter and bus -> Verification.

StepItemKey point
1Flow profileConfirm the duty requires a wide measuring range
2Conductivity checkVerify the medium meets >= 1 uS/cm
3Bore sizingChoose a bore from DN15 to DN300 for the line
4Ceramic tubeConfirm the ceramic tube suits the medium and temperature
5Converter and busSelect 4-20 mA / HART / Modbus / FF / Profibus PA as required
6VerificationConfirm the measuring span, approval and ordering code with the official datasheet; Ordering code per the official datasheet; verify with the manufacturer

Boundary: The wide range is a platform characteristic. Exact span, accuracy and approvals are per the official datasheet; refer to the official datasheet; verify with the manufacturer.

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX 5000 / OPTIFLUX 5300 product page https://www.krohnechina.com/zh/products/flow-measurement/flowmeters/electromagnetic-flowmeters/optiflux-5300

5. Complete Model Enumeration

Model familyPositionDescription
OPTIFLUX 4000Chemical and processPTFE / PFA lined full-bore meters for corrosive and higher-temperature industrial media
OPTIFLUX 5000Custody-transfer meteringCeramic measuring-tube meters for small-bore high-accuracy and metering duties
OPTIFLUX 6000Hygienic processHygienic full-bore meters with PFA liner for food, beverage and pharmaceutical duties
BATCHFLUXBatching and fillingLow-power batching flowmeters for dosing and filling applications
OPTIPROBEInsertion, large pipeInsertion electromagnetic flowmeters for large water and wastewater pipes
DWM 2000Insertion, medium-large pipeInsertion electromagnetic flowmeter with stainless steel housing for water and process media

6. Related Models

Related modelDescription
KROHNE OPTIFLUX 5100Ceramic metering meter with HART
KROHNE POWERFLUX 5030Small-bore ceramic meter for metering
KROHNE POWERFLUX 5300Full-bore wafer ceramic meter
KROHNE IFC 400Converter for SIL and metering applications

7. Common Spare Parts

Spare partDescription
Ceramic measuring tubeMatched to the original nominal bore
Measuring electrodeSelected against the original sensor datasheet
IFC converter moduleReplacement with matching protocol set
Excitation coilReplacement matched to the sensor size
Seal and gasket setMatched to the original tube assembly

8. Accessories

AccessoryDescription
IFC series converterSelected to the required protocol set
Fieldbus segment couplerFor Profibus PA or FF integration
Modbus interfaceFor plant communication networks
Grounding ringFor dependable earthing of the tube
Flange adapterMatched to the plant piping class

9. Disclaimer

The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources & Contact

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX 5000 / OPTIFLUX 5300 product page https://www.krohnechina.com/zh/products/flow-measurement/flowmeters/electromagnetic-flowmeters/optiflux-5300.

We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area