KROHNE OPTIFLUX 5300 Ceramic Electromagnetic Flowmeter DN15-300 Wide Range with
1. Product Overview
The KROHNE OPTIFLUX 5300 is the wide-measuring-range member of the OPTIFLUX 5000 ceramic metering platform. It combines a ceramic measuring tube with a broad flow range, so a single meter can cover duties where the flow rate varies considerably.
The model is specified DN15 to DN300 with conductivity >= 1 uS/cm and temperature up to +180 deg C. Depending on the signal converter, outputs include 4-20 mA, HART, Modbus, FF and Profibus PA. It is used for wide-range metering and custody-transfer applications, with OIML R117 and MI-005 approvals by configuration.
This page is a selection overview. The figures shown are published range values; refer to the official datasheet; verify with the manufacturer.



2. Technical Description
Measuring principle: Faraday electromagnetic induction for conductive liquids.
Nominal bore: DN15 to DN300.
Measuring tube: Ceramic, with a wide measuring range.
Conductivity: >= 1 uS/cm.
Process temperature: Up to +180 deg C.
Outputs: 4-20 mA / HART / Modbus / FF / Profibus PA depending on converter.
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Product type | Wide-range ceramic electromagnetic flowmeter |
| Series / model | KROHNE OPTIFLUX 5300 |
| Measuring principle | Faraday law of electromagnetic induction |
| Nominal bore | DN15 to DN300 |
| Measuring tube | Ceramic, wide measuring range |
| Conductivity | >= 1 uS/cm |
| Process temperature | Up to +180 deg C |
| Process pressure | refer to the official datasheet; verify with the manufacturer |
| Outputs | 4-20 mA, HART, Modbus, FF, Profibus PA by converter |
| Metering approval | OIML R117 / MI-005 by configuration; refer to the official datasheet; verify with the manufacturer |
| Version options | C compact / W wall remote / F field remote / R panel |
| Application | Wide-range metering and custody-transfer measurement |
| Accuracy and ordering | refer to the official datasheet; verify with the manufacturer; Ordering code per the official datasheet; verify with the manufacturer |
4. Selection Guide
Selection sequence: Flow profile -> Conductivity check -> Bore sizing -> Ceramic tube -> Converter and bus -> Verification.
| Step | Item | Key point |
|---|---|---|
| 1 | Flow profile | Confirm the duty requires a wide measuring range |
| 2 | Conductivity check | Verify the medium meets >= 1 uS/cm |
| 3 | Bore sizing | Choose a bore from DN15 to DN300 for the line |
| 4 | Ceramic tube | Confirm the ceramic tube suits the medium and temperature |
| 5 | Converter and bus | Select 4-20 mA / HART / Modbus / FF / Profibus PA as required |
| 6 | Verification | Confirm the measuring span, approval and ordering code with the official datasheet; Ordering code per the official datasheet; verify with the manufacturer |
Boundary: The wide range is a platform characteristic. Exact span, accuracy and approvals are per the official datasheet; refer to the official datasheet; verify with the manufacturer.
5. Complete Model Enumeration
| Model family | Position | Description |
|---|---|---|
| OPTIFLUX 4000 | Chemical and process | PTFE / PFA lined full-bore meters for corrosive and higher-temperature industrial media |
| OPTIFLUX 5000 | Custody-transfer metering | Ceramic measuring-tube meters for small-bore high-accuracy and metering duties |
| OPTIFLUX 6000 | Hygienic process | Hygienic full-bore meters with PFA liner for food, beverage and pharmaceutical duties |
| BATCHFLUX | Batching and filling | Low-power batching flowmeters for dosing and filling applications |
| OPTIPROBE | Insertion, large pipe | Insertion electromagnetic flowmeters for large water and wastewater pipes |
| DWM 2000 | Insertion, medium-large pipe | Insertion electromagnetic flowmeter with stainless steel housing for water and process media |
6. Related Models
| Related model | Description |
|---|---|
| KROHNE OPTIFLUX 5100 | Ceramic metering meter with HART |
| KROHNE POWERFLUX 5030 | Small-bore ceramic meter for metering |
| KROHNE POWERFLUX 5300 | Full-bore wafer ceramic meter |
| KROHNE IFC 400 | Converter for SIL and metering applications |
7. Common Spare Parts
| Spare part | Description |
|---|---|
| Ceramic measuring tube | Matched to the original nominal bore |
| Measuring electrode | Selected against the original sensor datasheet |
| IFC converter module | Replacement with matching protocol set |
| Excitation coil | Replacement matched to the sensor size |
| Seal and gasket set | Matched to the original tube assembly |
8. Accessories
| Accessory | Description |
|---|---|
| IFC series converter | Selected to the required protocol set |
| Fieldbus segment coupler | For Profibus PA or FF integration |
| Modbus interface | For plant communication networks |
| Grounding ring | For dependable earthing of the tube |
| Flange adapter | Matched to the plant piping class |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China