KROHNE OPTIFLUX 5100 Ceramic Electromagnetic Flowmeter DN2.5-100 with HART for M
1. Product Overview
The KROHNE OPTIFLUX 5100 is a ceramic measuring-tube flowmeter in the OPTIFLUX 5000 metering platform. It is supplied with HART communication and is aimed at metering duties where small flow rates must be measured accurately and the measuring tube must resist wear.
The model covers DN2.5 to DN100 with a conductivity requirement of >= 1 uS/cm and temperature up to +180 deg C, and provides 4-20 mA and HART outputs. Metering approvals such as OIML R117 and MI-005 can apply depending on the configuration; the applicable approval and accuracy class should be checked against the official datasheet.
This page is a selection overview. The figures shown are published range values; refer to the official datasheet; verify with the manufacturer.



2. Technical Description
Measuring principle: Faraday electromagnetic induction for conductive liquids.
Nominal bore: DN2.5 to DN100.
Measuring tube: Ceramic for wear resistance.
Conductivity: >= 1 uS/cm.
Process temperature: Up to +180 deg C.
Outputs: 4-20 mA and HART; metering approvals by configuration.
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Product type | Ceramic-tube electromagnetic flowmeter, metering duty |
| Series / model | KROHNE OPTIFLUX 5100 |
| Measuring principle | Faraday law of electromagnetic induction |
| Nominal bore | DN2.5 to DN100 |
| Measuring tube | Ceramic, wear resistant |
| Conductivity | >= 1 uS/cm |
| Process temperature | Up to +180 deg C |
| Process pressure | refer to the official datasheet; verify with the manufacturer |
| Outputs | 4-20 mA, HART |
| Metering approval | OIML R117 / MI-005 by configuration; refer to the official datasheet; verify with the manufacturer |
| Version options | C compact / W wall remote / F field remote / R panel |
| Application | Small-bore metering with high accuracy and wear resistance |
| Accuracy and ordering | refer to the official datasheet; verify with the manufacturer; Ordering code per the official datasheet; verify with the manufacturer |
4. Selection Guide
Selection sequence: Metering duty -> Conductivity check -> Bore sizing -> Ceramic tube -> Approval and outputs -> Verification.
| Step | Item | Key point |
|---|---|---|
| 1 | Metering duty | Confirm a metering or high-accuracy small-flow application |
| 2 | Conductivity check | Verify the medium meets >= 1 uS/cm |
| 3 | Bore sizing | Choose a bore from DN2.5 to DN100 for the flow range |
| 4 | Ceramic tube | Confirm the ceramic tube suits the medium and temperature |
| 5 | Approval and outputs | Check OIML R117 / MI-005 applicability and select 4-20 mA / HART |
| 6 | Verification | Confirm the final configuration against the official datasheet; Ordering code per the official datasheet; verify with the manufacturer |
Boundary: Approvals and accuracy depend on configuration. Verify the applicable version with the manufacturer; refer to the official datasheet; verify with the manufacturer.
5. Complete Model Enumeration
| Model family | Position | Description |
|---|---|---|
| OPTIFLUX 4000 | Chemical and process | PTFE / PFA lined full-bore meters for corrosive and higher-temperature industrial media |
| OPTIFLUX 5000 | Custody-transfer metering | Ceramic measuring-tube meters for small-bore high-accuracy and metering duties |
| OPTIFLUX 6000 | Hygienic process | Hygienic full-bore meters with PFA liner for food, beverage and pharmaceutical duties |
| BATCHFLUX | Batching and filling | Low-power batching flowmeters for dosing and filling applications |
| OPTIPROBE | Insertion, large pipe | Insertion electromagnetic flowmeters for large water and wastewater pipes |
| DWM 2000 | Insertion, medium-large pipe | Insertion electromagnetic flowmeter with stainless steel housing for water and process media |
6. Related Models
| Related model | Description |
|---|---|
| KROHNE POWERFLUX 5030 | Ceramic meter for small-flow metering duties |
| KROHNE OPTIFLUX 5300 | Wide-range ceramic meter with fieldbus options |
| KROHNE POWERFLUX 5300 | Full-bore wafer ceramic meter |
| KROHNE IFC 300 | Multiprotocol converter for metering applications |
7. Common Spare Parts
| Spare part | Description |
|---|---|
| Ceramic measuring tube | Matched to the original nominal bore |
| Measuring electrode | Selected against the original sensor datasheet |
| IFC converter module | Replacement with matching HART configuration |
| Excitation coil | Replacement matched to the sensor size |
| Seal and gasket set | Matched to the original tube assembly |
8. Accessories
| Accessory | Description |
|---|---|
| IFC signal converter | Compact, wall, field or panel version as required |
| HART communicator | For configuration and diagnostics |
| Grounding ring | For reliable earthing of the tube |
| Metering calibration service | Arranged with the manufacturer where required |
| Flange adapter | Matched to the plant piping class |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文
ENGLISH