Home » Products » KROHNE
KROHNE POWERFLUX 5030 Ceramic Electromagnetic Flowmeter DN2.5-100 for Small-Flow
KROHNE POWERFLUX 5030 Ceramic Electromagnetic Flowmeter DN2.5-100 for Small-Flow
KROHNE POWERFLUX 5030 Ceramic Electromagnetic Flowmeter DN2.5-100 for Small-Flow

KROHNE POWERFLUX 5030 Ceramic Electromagnetic Flowmeter DN2.5-100 for Small-Flow

Details

1. Product Overview

The KROHNE POWERFLUX 5030 is the industrial designation for a meter in the OPTIFLUX 5000 ceramic metering platform. It uses a ceramic measuring tube without a polymer liner, which gives good wear resistance for small-bore applications with high accuracy requirements.

The model is specified DN2.5 to DN100 with conductivity >= 1 uS/cm and temperature up to +180 deg C; it is offered at high pressure classes. Outputs are 4-20 mA and HART. Typical duties include small-flow measurement and metering tasks where a wear-resistant ceramic tube is preferred.

This page is a selection overview. The figures shown are published range values; refer to the official datasheet; verify with the manufacturer.

Above: product appearance / manufacturer literature image.

2. Technical Description

Measuring principle: Faraday electromagnetic induction for conductive liquids.

Nominal bore: DN2.5 to DN100.

Measuring tube: Ceramic, without a polymer liner.

Conductivity: >= 1 uS/cm.

Process temperature: Up to +180 deg C.

Outputs: 4-20 mA and HART; pressure class per the official datasheet.

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX 5000 / OPTIFLUX 5300 product page https://www.krohnechina.com/zh/products/flow-measurement/flowmeters/electromagnetic-flowmeters/optiflux-5300

3. Main Technical Specifications

ParameterSpecification / Description
Product typeCeramic-tube electromagnetic flowmeter, metering duty
Series / modelKROHNE POWERFLUX 5030
Measuring principleFaraday law of electromagnetic induction
Nominal boreDN2.5 to DN100
Measuring tubeCeramic, no polymer liner
Conductivity>= 1 uS/cm
Process temperatureUp to +180 deg C
Process pressureHigh pressure class; refer to the official datasheet; verify with the manufacturer
Outputs4-20 mA, HART
Signal converterIFC series, ordered separately
Version optionsC compact / W wall remote / F field remote / R panel
ApplicationSmall-flow metering and wear-resistant duties
Accuracy and orderingrefer to the official datasheet; verify with the manufacturer; Ordering code per the official datasheet; verify with the manufacturer
Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX 5000 / OPTIFLUX 5300 product page https://www.krohnechina.com/zh/products/flow-measurement/flowmeters/electromagnetic-flowmeters/optiflux-5300

4. Selection Guide

Selection sequence: Duty definition -> Conductivity check -> Bore sizing -> Ceramic tube -> Pressure and outputs -> Verification.

StepItemKey point
1Duty definitionConfirm a small-bore metering duty where wear resistance matters
2Conductivity checkVerify the medium meets >= 1 uS/cm
3Bore sizingChoose a bore from DN2.5 to DN100 for the expected flow range
4Ceramic tubeConfirm the ceramic measuring tube suits the medium and temperature
5Pressure and outputsCheck the pressure class and select 4-20 mA / HART outputs
6VerificationConfirm accuracy class and ordering code against the official datasheet; Ordering code per the official datasheet; verify with the manufacturer

Boundary: Ceramic tube ratings and accuracy classes are configuration dependent; refer to the official datasheet; verify with the manufacturer.

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX 5000 / OPTIFLUX 5300 product page https://www.krohnechina.com/zh/products/flow-measurement/flowmeters/electromagnetic-flowmeters/optiflux-5300

5. Complete Model Enumeration

Model familyPositionDescription
OPTIFLUX 4000Chemical and processPTFE / PFA lined full-bore meters for corrosive and higher-temperature industrial media
OPTIFLUX 5000Custody-transfer meteringCeramic measuring-tube meters for small-bore high-accuracy and metering duties
OPTIFLUX 6000Hygienic processHygienic full-bore meters with PFA liner for food, beverage and pharmaceutical duties
BATCHFLUXBatching and fillingLow-power batching flowmeters for dosing and filling applications
OPTIPROBEInsertion, large pipeInsertion electromagnetic flowmeters for large water and wastewater pipes
DWM 2000Insertion, medium-large pipeInsertion electromagnetic flowmeter with stainless steel housing for water and process media

6. Related Models

Related modelDescription
KROHNE OPTIFLUX 5100Ceramic metering meter with HART in the same platform
KROHNE OPTIFLUX 5300Wide-range ceramic metering meter
KROHNE POWERFLUX 5300Full-bore wafer ceramic meter
KROHNE IFC 100Compact HART signal converter

7. Common Spare Parts

Spare partDescription
Ceramic measuring tubeMatched to the original nominal bore
Measuring electrodeSelected against the original sensor datasheet
IFC converter moduleReplacement with matching 4-20 mA / HART setup
Excitation coilReplacement matched to the sensor size
Seal and gasket setMatched to the original ceramic tube assembly

8. Accessories

AccessoryDescription
IFC signal converterCompact, wall, field or panel version as required
HART communicatorFor configuration and diagnostics of the loop
Grounding ringFor reliable earthing of the measuring tube
Small-bore mounting kitFor alignment at DN2.5 to DN100
Flange adapterMatched to the plant piping class

9. Disclaimer

The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources & Contact

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX 5000 / OPTIFLUX 5300 product page https://www.krohnechina.com/zh/products/flow-measurement/flowmeters/electromagnetic-flowmeters/optiflux-5300.

We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area