1. Product Overview
The KROHNE POWERFLUX 5030 is the industrial designation for a meter in the OPTIFLUX 5000 ceramic metering platform. It uses a ceramic measuring tube without a polymer liner, which gives good wear resistance for small-bore applications with high accuracy requirements.
The model is specified DN2.5 to DN100 with conductivity >= 1 uS/cm and temperature up to +180 deg C; it is offered at high pressure classes. Outputs are 4-20 mA and HART. Typical duties include small-flow measurement and metering tasks where a wear-resistant ceramic tube is preferred.
This page is a selection overview. The figures shown are published range values; refer to the official datasheet; verify with the manufacturer.



2. Technical Description
Measuring principle: Faraday electromagnetic induction for conductive liquids.
Nominal bore: DN2.5 to DN100.
Measuring tube: Ceramic, without a polymer liner.
Conductivity: >= 1 uS/cm.
Process temperature: Up to +180 deg C.
Outputs: 4-20 mA and HART; pressure class per the official datasheet.
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Product type | Ceramic-tube electromagnetic flowmeter, metering duty |
| Series / model | KROHNE POWERFLUX 5030 |
| Measuring principle | Faraday law of electromagnetic induction |
| Nominal bore | DN2.5 to DN100 |
| Measuring tube | Ceramic, no polymer liner |
| Conductivity | >= 1 uS/cm |
| Process temperature | Up to +180 deg C |
| Process pressure | High pressure class; refer to the official datasheet; verify with the manufacturer |
| Outputs | 4-20 mA, HART |
| Signal converter | IFC series, ordered separately |
| Version options | C compact / W wall remote / F field remote / R panel |
| Application | Small-flow metering and wear-resistant duties |
| Accuracy and ordering | refer to the official datasheet; verify with the manufacturer; Ordering code per the official datasheet; verify with the manufacturer |
4. Selection Guide
Selection sequence: Duty definition -> Conductivity check -> Bore sizing -> Ceramic tube -> Pressure and outputs -> Verification.
| Step | Item | Key point |
|---|---|---|
| 1 | Duty definition | Confirm a small-bore metering duty where wear resistance matters |
| 2 | Conductivity check | Verify the medium meets >= 1 uS/cm |
| 3 | Bore sizing | Choose a bore from DN2.5 to DN100 for the expected flow range |
| 4 | Ceramic tube | Confirm the ceramic measuring tube suits the medium and temperature |
| 5 | Pressure and outputs | Check the pressure class and select 4-20 mA / HART outputs |
| 6 | Verification | Confirm accuracy class and ordering code against the official datasheet; Ordering code per the official datasheet; verify with the manufacturer |
Boundary: Ceramic tube ratings and accuracy classes are configuration dependent; refer to the official datasheet; verify with the manufacturer.
5. Complete Model Enumeration
| Model family | Position | Description |
|---|---|---|
| OPTIFLUX 4000 | Chemical and process | PTFE / PFA lined full-bore meters for corrosive and higher-temperature industrial media |
| OPTIFLUX 5000 | Custody-transfer metering | Ceramic measuring-tube meters for small-bore high-accuracy and metering duties |
| OPTIFLUX 6000 | Hygienic process | Hygienic full-bore meters with PFA liner for food, beverage and pharmaceutical duties |
| BATCHFLUX | Batching and filling | Low-power batching flowmeters for dosing and filling applications |
| OPTIPROBE | Insertion, large pipe | Insertion electromagnetic flowmeters for large water and wastewater pipes |
| DWM 2000 | Insertion, medium-large pipe | Insertion electromagnetic flowmeter with stainless steel housing for water and process media |
6. Related Models
| Related model | Description |
|---|---|
| KROHNE OPTIFLUX 5100 | Ceramic metering meter with HART in the same platform |
| KROHNE OPTIFLUX 5300 | Wide-range ceramic metering meter |
| KROHNE POWERFLUX 5300 | Full-bore wafer ceramic meter |
| KROHNE IFC 100 | Compact HART signal converter |
7. Common Spare Parts
| Spare part | Description |
|---|---|
| Ceramic measuring tube | Matched to the original nominal bore |
| Measuring electrode | Selected against the original sensor datasheet |
| IFC converter module | Replacement with matching 4-20 mA / HART setup |
| Excitation coil | Replacement matched to the sensor size |
| Seal and gasket set | Matched to the original ceramic tube assembly |
8. Accessories
| Accessory | Description |
|---|---|
| IFC signal converter | Compact, wall, field or panel version as required |
| HART communicator | For configuration and diagnostics of the loop |
| Grounding ring | For reliable earthing of the measuring tube |
| Small-bore mounting kit | For alignment at DN2.5 to DN100 |
| Flange adapter | Matched to the plant piping class |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文
ENGLISH