KROHNE POWERFLUX 4300 Stainless Steel Electromagnetic Flowmeter DN25-1000 PN40
1. Product Overview
The KROHNE POWERFLUX 4300 is the industrial designation for a stainless steel, corrosion-resistant meter in the OPTIFLUX 4000 platform. It is a full-bore electromagnetic flowmeter used for general industrial duty where aggressive media are present and a conventional 4-20 mA signal is required.
This model is specified DN25 to DN1000 within the DN2.5 to DN3000 family. It uses PTFE or PFA liners with conductivity >= 1 uS/cm, temperature up to +180 deg C and pressure up to PN40, and offers 4-20 mA, HART and fieldbus outputs through the IFC converter.
This page is a selection overview. The figures shown are published range values; refer to the official datasheet; verify with the manufacturer.



2. Technical Description
Measuring principle: Faraday electromagnetic induction for conductive media.
Nominal bore: DN25 to DN1000 within the DN2.5 to DN3000 family.
Body and liner: Stainless steel with PTFE or PFA liner.
Conductivity: >= 1 uS/cm.
Process temperature and pressure: Up to +180 deg C and up to PN40.
Outputs: 4-20 mA / HART / fieldbus variants with the IFC converter.
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Product type | Full-bore electromagnetic flowmeter, industrial corrosion-resistant duty |
| Series / model | KROHNE POWERFLUX 4300 |
| Measuring principle | Faraday law of electromagnetic induction |
| Nominal bore | DN25 to DN1000 (family DN2.5 to DN3000) |
| Liner | PTFE or PFA |
| Conductivity | >= 1 uS/cm |
| Process temperature | Up to +180 deg C |
| Process pressure | Up to PN40 |
| Outputs | 4-20 mA, HART, fieldbus variants via IFC converter |
| Signal converter | IFC series, ordered separately |
| Version options | C compact / W wall remote / F field remote / R panel |
| Application | General industrial corrosion-resistant full-bore measurement |
| Accuracy and ordering | refer to the official datasheet; verify with the manufacturer; Ordering code per the official datasheet; verify with the manufacturer |
4. Selection Guide
Selection sequence: Medium check -> Bore sizing -> Body and liner -> Operating limits -> Converter and outputs -> Verification.
| Step | Item | Key point |
|---|---|---|
| 1 | Medium check | Confirm a conductive industrial medium with conductivity >= 1 uS/cm |
| 2 | Bore sizing | Choose DN25 to DN1000 to match the process line |
| 3 | Body and liner | Select the stainless steel body with PTFE or PFA for corrosion resistance |
| 4 | Operating limits | Check temperature up to +180 deg C and pressure up to PN40 |
| 5 | Converter and outputs | Choose the IFC converter with 4-20 mA, HART or fieldbus |
| 6 | Verification | Confirm the final configuration against the official datasheet; Ordering code per the official datasheet; verify with the manufacturer |
Boundary: The bore range shown is the model range within the family. Final ratings and ordering code are per the official datasheet; Ordering code per the official datasheet; verify with the manufacturer.
5. Complete Model Enumeration
| Model family | Position | Description |
|---|---|---|
| OPTIFLUX 4000 | Chemical and process | PTFE / PFA lined full-bore meters for corrosive and higher-temperature industrial media |
| OPTIFLUX 5000 | Custody-transfer metering | Ceramic measuring-tube meters for small-bore high-accuracy and metering duties |
| OPTIFLUX 6000 | Hygienic process | Hygienic full-bore meters with PFA liner for food, beverage and pharmaceutical duties |
| BATCHFLUX | Batching and filling | Low-power batching flowmeters for dosing and filling applications |
| OPTIPROBE | Insertion, large pipe | Insertion electromagnetic flowmeters for large water and wastewater pipes |
| DWM 2000 | Insertion, medium-large pipe | Insertion electromagnetic flowmeter with stainless steel housing for water and process media |
6. Related Models
| Related model | Description |
|---|---|
| KROHNE OPTIFLUX 4100 | Stainless steel chemical meter in the same platform |
| KROHNE OPTIFLUX 4300 | Low-conductivity chemical meter |
| KROHNE POWERFLUX 4030 | Industrial meter designation in the 4000 platform |
| KROHNE IFC 300 | Multiprotocol signal converter |
7. Common Spare Parts
| Spare part | Description |
|---|---|
| Measuring electrode | Matched to the original bore and liner |
| PTFE or PFA liner | Selected to the original nominal bore |
| IFC converter module | Replacement with matching output configuration |
| Excitation coil | Replacement matched to the sensor size |
| Flange gasket set | Matched to the original flange rating |
8. Accessories
| Accessory | Description |
|---|---|
| IFC series converter | Compact, wall, field or panel version as required |
| Grounding ring | For dependable earthing of the measuring tube |
| Fieldbus segment coupler | For Profibus PA or FF integration |
| Remote mounting kit | Where the converter is installed away from the sensor |
| Flange adapter | Matched to the plant piping class |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文
ENGLISH