The KROHNE OPTIFLUX 4300 belongs to the OPTIFLUX 4000 platform and is applied where the medium has low conductivity and is corrosive. It is a full-bore electromagnetic flowmeter with PTFE or PFA lining, intended for chemical and process duties that are beyond a standard water meter.

The series covers DN2.5 to DN3000 with a conductivity requirement of >= 1 uS/cm, temperature up to +180 deg C and pressure up to PN40. Outputs include 4-20 mA, HART and fieldbus variants through the IFC converter. Where the conductivity is lower than this range, the capacitive measuring principle of the OPTIFLUX 7300 series should be evaluated.

This page is a selection overview. The figures shown are published range values; refer to the official datasheet; verify with the manufacturer.

Above: product appearance / manufacturer literature image.

2. Technical Description

Measuring principle: Faraday electromagnetic induction for conductive liquids.

Nominal bore: DN2.5 to DN3000 family range.

Liner options: PTFE or PFA for corrosive media.

Conductivity: >= 1 uS/cm for this lined sensor design.

Process temperature: Up to +180 deg C.

Process pressure and outputs: Up to PN40; 4-20 mA, HART and fieldbus with IFC.

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX 4000 product page https://www.krohne.com/en/products/electromagnetic-flowmeters/optiflux/

3. Main Technical Specifications

ParameterSpecification / Description
Product typeFull-bore electromagnetic flowmeter, low-conductivity chemical duty
Series / modelKROHNE OPTIFLUX 4300
Measuring principleFaraday law of electromagnetic induction
Nominal boreDN2.5 to DN3000
LinerPTFE or PFA
Conductivity>= 1 uS/cm
Process temperatureUp to +180 deg C
Process pressureUp to PN40
Outputs4-20 mA, HART, fieldbus variants via IFC converter
Signal converterIFC series, ordered separately
Version optionsC compact / W wall remote / F field remote / R panel
ApplicationLow-conductivity and corrosive chemical media
Accuracy and orderingrefer to the official datasheet; verify with the manufacturer; Ordering code per the official datasheet; verify with the manufacturer
Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX 4000 product page https://www.krohne.com/en/products/electromagnetic-flowmeters/optiflux/

4. Selection Guide

Selection sequence: Conductivity check -> Lower conductivity -> Bore sizing -> Liner and limits -> Converter and outputs -> Verification.

StepItemKey point
1Conductivity checkConfirm the medium meets >= 1 uS/cm for the lined sensor
2Lower conductivityFor values below this range evaluate the OPTIFLUX 7300 capacitive series
3Bore sizingChoose a nominal bore from DN2.5 to DN3000 for the line
4Liner and limitsSelect PTFE or PFA and check +180 deg C and PN40
5Converter and outputsChoose the IFC converter with 4-20 mA, HART or fieldbus
6VerificationConfirm the final configuration against the official datasheet; Ordering code per the official datasheet; verify with the manufacturer

Boundary: This model addresses conductive media at >= 1 uS/cm. For lower conductivity use a capacitive meter; refer to the official datasheet; verify with the manufacturer.

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX 4000 product page https://www.krohne.com/en/products/electromagnetic-flowmeters/optiflux/

5. Complete Model Enumeration

Model familyPositionDescription
OPTIFLUX 4000Chemical and processPTFE / PFA lined full-bore meters for corrosive and higher-temperature industrial media
OPTIFLUX 5000Custody-transfer meteringCeramic measuring-tube meters for small-bore high-accuracy and metering duties
OPTIFLUX 6000Hygienic processHygienic full-bore meters with PFA liner for food, beverage and pharmaceutical duties
BATCHFLUXBatching and fillingLow-power batching flowmeters for dosing and filling applications
OPTIPROBEInsertion, large pipeInsertion electromagnetic flowmeters for large water and wastewater pipes
DWM 2000Insertion, medium-large pipeInsertion electromagnetic flowmeter with stainless steel housing for water and process media

6. Related Models

Related modelDescription
KROHNE OPTIFLUX 4100Stainless steel chemical meter in the same platform
KROHNE OPTIFLUX 4050Wear resistant chemical meter
KROHNE POWERFLUX 4300Stainless steel industrial meter in the 4000 platform
KROHNE IFC 300Multiprotocol converter with HART and fieldbus

7. Common Spare Parts

Spare partDescription
Measuring electrodeMatched to the original bore and liner
PTFE or PFA linerSelected to the original nominal bore
IFC converter moduleReplacement with matching protocol configuration
Excitation coilReplacement matched to the sensor size
Flange gasket setMatched to the original flange rating

8. Accessories

AccessoryDescription
IFC series converterSelected to the required output protocol
Fieldbus segment couplerFor Profibus PA or FF integration
Grounding ringFor dependable earthing of the tube
Remote mounting kitFor wall or field converter separation
Flange adapterMatched to the plant piping class

9. Disclaimer

The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources & Contact

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX 4000 product page https://www.krohne.com/en/products/electromagnetic-flowmeters/optiflux/.

We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area