KROHNE OPTIFLUX 4300 Electromagnetic Flowmeter DN2.5-3000 for Low Conductivity C
1. Product Overview
The KROHNE OPTIFLUX 4300 belongs to the OPTIFLUX 4000 platform and is applied where the medium has low conductivity and is corrosive. It is a full-bore electromagnetic flowmeter with PTFE or PFA lining, intended for chemical and process duties that are beyond a standard water meter.
The series covers DN2.5 to DN3000 with a conductivity requirement of >= 1 uS/cm, temperature up to +180 deg C and pressure up to PN40. Outputs include 4-20 mA, HART and fieldbus variants through the IFC converter. Where the conductivity is lower than this range, the capacitive measuring principle of the OPTIFLUX 7300 series should be evaluated.
This page is a selection overview. The figures shown are published range values; refer to the official datasheet; verify with the manufacturer.



2. Technical Description
Measuring principle: Faraday electromagnetic induction for conductive liquids.
Nominal bore: DN2.5 to DN3000 family range.
Liner options: PTFE or PFA for corrosive media.
Conductivity: >= 1 uS/cm for this lined sensor design.
Process temperature: Up to +180 deg C.
Process pressure and outputs: Up to PN40; 4-20 mA, HART and fieldbus with IFC.
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Product type | Full-bore electromagnetic flowmeter, low-conductivity chemical duty |
| Series / model | KROHNE OPTIFLUX 4300 |
| Measuring principle | Faraday law of electromagnetic induction |
| Nominal bore | DN2.5 to DN3000 |
| Liner | PTFE or PFA |
| Conductivity | >= 1 uS/cm |
| Process temperature | Up to +180 deg C |
| Process pressure | Up to PN40 |
| Outputs | 4-20 mA, HART, fieldbus variants via IFC converter |
| Signal converter | IFC series, ordered separately |
| Version options | C compact / W wall remote / F field remote / R panel |
| Application | Low-conductivity and corrosive chemical media |
| Accuracy and ordering | refer to the official datasheet; verify with the manufacturer; Ordering code per the official datasheet; verify with the manufacturer |
4. Selection Guide
Selection sequence: Conductivity check -> Lower conductivity -> Bore sizing -> Liner and limits -> Converter and outputs -> Verification.
| Step | Item | Key point |
|---|---|---|
| 1 | Conductivity check | Confirm the medium meets >= 1 uS/cm for the lined sensor |
| 2 | Lower conductivity | For values below this range evaluate the OPTIFLUX 7300 capacitive series |
| 3 | Bore sizing | Choose a nominal bore from DN2.5 to DN3000 for the line |
| 4 | Liner and limits | Select PTFE or PFA and check +180 deg C and PN40 |
| 5 | Converter and outputs | Choose the IFC converter with 4-20 mA, HART or fieldbus |
| 6 | Verification | Confirm the final configuration against the official datasheet; Ordering code per the official datasheet; verify with the manufacturer |
Boundary: This model addresses conductive media at >= 1 uS/cm. For lower conductivity use a capacitive meter; refer to the official datasheet; verify with the manufacturer.
5. Complete Model Enumeration
| Model family | Position | Description |
|---|---|---|
| OPTIFLUX 4000 | Chemical and process | PTFE / PFA lined full-bore meters for corrosive and higher-temperature industrial media |
| OPTIFLUX 5000 | Custody-transfer metering | Ceramic measuring-tube meters for small-bore high-accuracy and metering duties |
| OPTIFLUX 6000 | Hygienic process | Hygienic full-bore meters with PFA liner for food, beverage and pharmaceutical duties |
| BATCHFLUX | Batching and filling | Low-power batching flowmeters for dosing and filling applications |
| OPTIPROBE | Insertion, large pipe | Insertion electromagnetic flowmeters for large water and wastewater pipes |
| DWM 2000 | Insertion, medium-large pipe | Insertion electromagnetic flowmeter with stainless steel housing for water and process media |
6. Related Models
| Related model | Description |
|---|---|
| KROHNE OPTIFLUX 4100 | Stainless steel chemical meter in the same platform |
| KROHNE OPTIFLUX 4050 | Wear resistant chemical meter |
| KROHNE POWERFLUX 4300 | Stainless steel industrial meter in the 4000 platform |
| KROHNE IFC 300 | Multiprotocol converter with HART and fieldbus |
7. Common Spare Parts
| Spare part | Description |
|---|---|
| Measuring electrode | Matched to the original bore and liner |
| PTFE or PFA liner | Selected to the original nominal bore |
| IFC converter module | Replacement with matching protocol configuration |
| Excitation coil | Replacement matched to the sensor size |
| Flange gasket set | Matched to the original flange rating |
8. Accessories
| Accessory | Description |
|---|---|
| IFC series converter | Selected to the required output protocol |
| Fieldbus segment coupler | For Profibus PA or FF integration |
| Grounding ring | For dependable earthing of the tube |
| Remote mounting kit | For wall or field converter separation |
| Flange adapter | Matched to the plant piping class |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文
ENGLISH