Home » Products » KROHNE
KROHNE OPTIFLUX 4100 Stainless Steel Electromagnetic Flowmeter DN2.5-3000 PN40 f
KROHNE OPTIFLUX 4100 Stainless Steel Electromagnetic Flowmeter DN2.5-3000 PN40 f
KROHNE OPTIFLUX 4100 Stainless Steel Electromagnetic Flowmeter DN2.5-3000 PN40 f

KROHNE OPTIFLUX 4100 Stainless Steel Electromagnetic Flowmeter DN2.5-3000 PN40 f

Details

1. Product Overview

The KROHNE OPTIFLUX 4100 is the stainless steel version of the OPTIFLUX 4000 platform, intended for general chemical duties where wear and corrosion resistance are both required. It is a full-bore electromagnetic flowmeter operating on Faraday's law of induction, with no moving parts in the measuring tube.

The series covers DN2.5 to DN3000 and uses PTFE or PFA liners, with a conductivity requirement of >= 1 uS/cm, process temperature up to +180 deg C and pressure up to PN40 / Class 300. With an IFC series signal converter it provides 4-20 mA, HART, FF, Profibus PA and Modbus outputs.

This page is a selection overview. The figures shown are published range values; refer to the official datasheet; verify with the manufacturer.

Above: product appearance / manufacturer literature image.

2. Technical Description

Measuring principle: Faraday electromagnetic induction for conductive liquids and slurries.

Nominal bore: DN2.5 to DN3000 family range.

Body and liner: Stainless steel body with PTFE or PFA liner.

Process temperature: Up to +180 deg C, depending on the liner.

Process pressure: Up to PN40 / Class 300.

Outputs: 4-20 mA / HART / FF / Profibus PA / Modbus with the IFC series converter.

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX 4000 product page https://www.krohne.com/en/products/electromagnetic-flowmeters/optiflux/

3. Main Technical Specifications

ParameterSpecification / Description
Product typeFull-bore electromagnetic flowmeter, stainless steel
Series / modelKROHNE OPTIFLUX 4100
Measuring principleFaraday law of electromagnetic induction
Nominal boreDN2.5 to DN3000
LinerPTFE or PFA
Conductivity>= 1 uS/cm
Process temperatureUp to +180 deg C, depending on liner
Process pressureUp to PN40 / Class 300
Outputs4-20 mA, HART, FF, Profibus PA, Modbus
Signal converterIFC series, ordered separately
Version optionsC compact / W wall remote / F field remote / R panel
ApplicationCorrosive and abrasive chemical media at general industrial duty
Accuracy and orderingrefer to the official datasheet; verify with the manufacturer; Ordering code per the official datasheet; verify with the manufacturer
Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX 4000 product page https://www.krohne.com/en/products/electromagnetic-flowmeters/optiflux/

4. Selection Guide

Selection sequence: Medium check -> Bore sizing -> Body and liner -> Operating limits -> Converter and bus -> Verification.

StepItemKey point
1Medium checkConfirm a conductive medium with conductivity >= 1 uS/cm
2Bore sizingChoose a nominal bore from DN2.5 to DN3000 for the process line
3Body and linerUse the stainless steel body with PTFE or PFA for corrosive or abrasive media
4Operating limitsCheck temperature up to +180 deg C and pressure up to PN40 / Class 300
5Converter and busSelect the IFC converter and 4-20 mA / HART / FF / Profibus PA / Modbus outputs
6VerificationConfirm the complete configuration against the official datasheet; Ordering code per the official datasheet; verify with the manufacturer

Boundary: Published figures are family limits. Final wetted materials, ratings and ordering code are per the official datasheet; Ordering code per the official datasheet; verify with the manufacturer.

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX 4000 product page https://www.krohne.com/en/products/electromagnetic-flowmeters/optiflux/

5. Complete Model Enumeration

Model familyPositionDescription
OPTIFLUX 4000Chemical and processPTFE / PFA lined full-bore meters for corrosive and higher-temperature industrial media
OPTIFLUX 5000Custody-transfer meteringCeramic measuring-tube meters for small-bore high-accuracy and metering duties
OPTIFLUX 6000Hygienic processHygienic full-bore meters with PFA liner for food, beverage and pharmaceutical duties
BATCHFLUXBatching and fillingLow-power batching flowmeters for dosing and filling applications
OPTIPROBEInsertion, large pipeInsertion electromagnetic flowmeters for large water and wastewater pipes
DWM 2000Insertion, medium-large pipeInsertion electromagnetic flowmeter with stainless steel housing for water and process media

6. Related Models

Related modelDescription
KROHNE OPTIFLUX 4300Low-conductivity chemical meter in the same platform
KROHNE POWERFLUX 4300Stainless steel industrial meter in the 4000 platform
KROHNE OPTIFLUX 4050Wear and corrosion resistant chemical meter
KROHNE IFC 300Multiprotocol signal converter for process integration

7. Common Spare Parts

Spare partDescription
Measuring electrodeMatched to the original bore and liner material
PTFE or PFA linerSelected to the original nominal bore
IFC converter moduleReplacement matched to the original protocol set
Excitation coilReplacement matched to the sensor size
Grounding ring and gasketsMatched to the original flange rating

8. Accessories

AccessoryDescription
IFC series converterCompact, wall, field or panel version as required
Profibus PA / FF segment couplerFor fieldbus integration
Grounding ringFor reliable earthing of the measuring tube
Remote mounting kitFor wall or field separation of the converter
Flange adapterMatched to the plant piping class

9. Disclaimer

The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources & Contact

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX 4000 product page https://www.krohne.com/en/products/electromagnetic-flowmeters/optiflux/.

We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area