KROHNE OPTIFLUX 4100 Stainless Steel Electromagnetic Flowmeter DN2.5-3000 PN40 f
1. Product Overview
The KROHNE OPTIFLUX 4100 is the stainless steel version of the OPTIFLUX 4000 platform, intended for general chemical duties where wear and corrosion resistance are both required. It is a full-bore electromagnetic flowmeter operating on Faraday's law of induction, with no moving parts in the measuring tube.
The series covers DN2.5 to DN3000 and uses PTFE or PFA liners, with a conductivity requirement of >= 1 uS/cm, process temperature up to +180 deg C and pressure up to PN40 / Class 300. With an IFC series signal converter it provides 4-20 mA, HART, FF, Profibus PA and Modbus outputs.
This page is a selection overview. The figures shown are published range values; refer to the official datasheet; verify with the manufacturer.



2. Technical Description
Measuring principle: Faraday electromagnetic induction for conductive liquids and slurries.
Nominal bore: DN2.5 to DN3000 family range.
Body and liner: Stainless steel body with PTFE or PFA liner.
Process temperature: Up to +180 deg C, depending on the liner.
Process pressure: Up to PN40 / Class 300.
Outputs: 4-20 mA / HART / FF / Profibus PA / Modbus with the IFC series converter.
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Product type | Full-bore electromagnetic flowmeter, stainless steel |
| Series / model | KROHNE OPTIFLUX 4100 |
| Measuring principle | Faraday law of electromagnetic induction |
| Nominal bore | DN2.5 to DN3000 |
| Liner | PTFE or PFA |
| Conductivity | >= 1 uS/cm |
| Process temperature | Up to +180 deg C, depending on liner |
| Process pressure | Up to PN40 / Class 300 |
| Outputs | 4-20 mA, HART, FF, Profibus PA, Modbus |
| Signal converter | IFC series, ordered separately |
| Version options | C compact / W wall remote / F field remote / R panel |
| Application | Corrosive and abrasive chemical media at general industrial duty |
| Accuracy and ordering | refer to the official datasheet; verify with the manufacturer; Ordering code per the official datasheet; verify with the manufacturer |
4. Selection Guide
Selection sequence: Medium check -> Bore sizing -> Body and liner -> Operating limits -> Converter and bus -> Verification.
| Step | Item | Key point |
|---|---|---|
| 1 | Medium check | Confirm a conductive medium with conductivity >= 1 uS/cm |
| 2 | Bore sizing | Choose a nominal bore from DN2.5 to DN3000 for the process line |
| 3 | Body and liner | Use the stainless steel body with PTFE or PFA for corrosive or abrasive media |
| 4 | Operating limits | Check temperature up to +180 deg C and pressure up to PN40 / Class 300 |
| 5 | Converter and bus | Select the IFC converter and 4-20 mA / HART / FF / Profibus PA / Modbus outputs |
| 6 | Verification | Confirm the complete configuration against the official datasheet; Ordering code per the official datasheet; verify with the manufacturer |
Boundary: Published figures are family limits. Final wetted materials, ratings and ordering code are per the official datasheet; Ordering code per the official datasheet; verify with the manufacturer.
5. Complete Model Enumeration
| Model family | Position | Description |
|---|---|---|
| OPTIFLUX 4000 | Chemical and process | PTFE / PFA lined full-bore meters for corrosive and higher-temperature industrial media |
| OPTIFLUX 5000 | Custody-transfer metering | Ceramic measuring-tube meters for small-bore high-accuracy and metering duties |
| OPTIFLUX 6000 | Hygienic process | Hygienic full-bore meters with PFA liner for food, beverage and pharmaceutical duties |
| BATCHFLUX | Batching and filling | Low-power batching flowmeters for dosing and filling applications |
| OPTIPROBE | Insertion, large pipe | Insertion electromagnetic flowmeters for large water and wastewater pipes |
| DWM 2000 | Insertion, medium-large pipe | Insertion electromagnetic flowmeter with stainless steel housing for water and process media |
6. Related Models
| Related model | Description |
|---|---|
| KROHNE OPTIFLUX 4300 | Low-conductivity chemical meter in the same platform |
| KROHNE POWERFLUX 4300 | Stainless steel industrial meter in the 4000 platform |
| KROHNE OPTIFLUX 4050 | Wear and corrosion resistant chemical meter |
| KROHNE IFC 300 | Multiprotocol signal converter for process integration |
7. Common Spare Parts
| Spare part | Description |
|---|---|
| Measuring electrode | Matched to the original bore and liner material |
| PTFE or PFA liner | Selected to the original nominal bore |
| IFC converter module | Replacement matched to the original protocol set |
| Excitation coil | Replacement matched to the sensor size |
| Grounding ring and gaskets | Matched to the original flange rating |
8. Accessories
| Accessory | Description |
|---|---|
| IFC series converter | Compact, wall, field or panel version as required |
| Profibus PA / FF segment coupler | For fieldbus integration |
| Grounding ring | For reliable earthing of the measuring tube |
| Remote mounting kit | For wall or field separation of the converter |
| Flange adapter | Matched to the plant piping class |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文
ENGLISH