1. Product Overview

The KROHNE OPTIFLUX 4050 is the main chemical-service model of the OPTIFLUX 4000 platform. It is designed for wear-resistant and corrosion-resistant measurement of aggressive industrial media at temperatures up to +180 deg C.

The family covers DN2.5 to DN3000, with this model specified DN2.5 to DN1000. It uses PTFE or PFA liners, requires conductivity of >= 1 uS/cm and withstands process pressure up to PN40 / Class 300. With the IFC series converter it provides 4-20 mA, HART, FF, Profibus PA and Modbus outputs.

This page is a selection overview. The figures shown are published range values; refer to the official datasheet; verify with the manufacturer.

Above: product appearance / manufacturer literature image.

2. Technical Description

Measuring principle: Faraday electromagnetic induction for conductive media.

Nominal bore: DN2.5 to DN3000 family; this model DN2.5 to DN1000.

Liner options: PTFE or PFA for corrosive and abrasive media.

Process temperature: Up to +180 deg C.

Process pressure: Up to PN40 / Class 300.

Outputs: 4-20 mA / HART / FF / Profibus PA / Modbus.

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX product page https://www.krohne.com/en/products/electromagnetic-flowmeters/optiflux/

3. Main Technical Specifications

ParameterSpecification / Description
Product typeFull-bore electromagnetic flowmeter, chemical service
Series / modelKROHNE OPTIFLUX 4050
Measuring principleFaraday law of electromagnetic induction
Nominal boreDN2.5 to DN1000 (family DN2.5 to DN3000)
LinerPTFE or PFA
Conductivity>= 1 uS/cm
Process temperatureUp to +180 deg C
Process pressureUp to PN40 / Class 300
Outputs4-20 mA, HART, FF, Profibus PA, Modbus
Signal converterIFC series, ordered separately
Version optionsC compact / W wall remote / F field remote / R panel
ApplicationCorrosive and abrasive chemical media up to +180 deg C
Accuracy and orderingrefer to the official datasheet; verify with the manufacturer; Ordering code per the official datasheet; verify with the manufacturer
Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX product page https://www.krohne.com/en/products/electromagnetic-flowmeters/optiflux/

4. Selection Guide

Selection sequence: Medium check -> Bore sizing -> Liner selection -> Operating limits -> Converter and bus -> Verification.

StepItemKey point
1Medium checkConfirm conductivity >= 1 uS/cm and the corrosive or abrasive nature of the medium
2Bore sizingChoose DN2.5 to DN1000 to match the process line
3Liner selectionSelect PTFE or PFA for the medium and temperature
4Operating limitsVerify +180 deg C maximum temperature and PN40 / Class 300 pressure
5Converter and busChoose the IFC converter and 4-20 mA / HART / FF / Profibus PA / Modbus outputs
6VerificationConfirm the complete configuration against the official datasheet; Ordering code per the official datasheet; verify with the manufacturer

Boundary: Published figures are family limits. Final liner, ratings and ordering code are per the official datasheet; Ordering code per the official datasheet; verify with the manufacturer.

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX product page https://www.krohne.com/en/products/electromagnetic-flowmeters/optiflux/

5. Complete Model Enumeration

Model familyPositionDescription
OPTIFLUX 2000General-purpose full-boreFull-bore electromagnetic flowmeters for water, wastewater and general industrial duty
OPTIFLUX 4000Chemical and processPTFE / PFA lined meters for corrosive and higher-temperature industrial media
WATERFLUX 3000Water utility meterBattery-powered water meters with no straight-run requirement and bidirectional measurement
TIDALFLUX 2300Partially filled pipeElectromagnetic flowmeter with integral level measurement for gravity and combined sewers
AF-E 400Legacy seriesEarlier 4-20 mA transmitter / sensor combination for existing automation loops

6. Related Models

Related modelDescription
KROHNE POWERFLUX 4030Chemical and power industry meter in the 4000 platform
KROHNE OPTIFLUX 4100Stainless steel wear-resistant chemical meter
KROHNE OPTIFLUX 2050General-purpose full-bore meter for water duty
KROHNE IFC 300Multiprotocol signal converter for chemical service

7. Common Spare Parts

Spare partDescription
Measuring electrodeMatched to the original bore and liner material
PTFE or PFA linerSelected to the original nominal bore
IFC converter moduleReplacement matched to the original protocol set
Excitation coilReplacement matched to the sensor size
Grounding ring and gasketsMatched to the original flange rating

8. Accessories

AccessoryDescription
IFC series converterCompact, wall, field or panel version as required
Profibus PA / FF segment couplerFor fieldbus integration
Grounding ringFor reliable earthing of the measuring tube
Remote mounting kitFor wall or field converter separation
Flange adapterMatched to the plant piping class

9. Disclaimer

The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources & Contact

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX product page https://www.krohne.com/en/products/electromagnetic-flowmeters/optiflux/.

We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area