Home » Products » KROHNE
KROHNE POWERFLUX 4030 Electromagnetic Flowmeter DN25-1000 Full-Bore Design
KROHNE POWERFLUX 4030 Electromagnetic Flowmeter DN25-1000 Full-Bore Design
KROHNE POWERFLUX 4030 Electromagnetic Flowmeter DN25-1000 Full-Bore Design

KROHNE POWERFLUX 4030 Electromagnetic Flowmeter DN25-1000 Full-Bore Design

Details

1. Product Overview

The KROHNE POWERFLUX 4030 belongs to the OPTIFLUX 4000 platform and is the designation used for chemical and power industry applications. It is a full-bore electromagnetic flowmeter for higher-temperature and general industrial duties.

The family covers DN2.5 to DN3000, with this model specified DN25 to DN1000. PTFE or PFA liners, a conductivity requirement of >= 1 uS/cm, process temperature up to +180 deg C and pressure up to PN40 / Class 300 make it suitable for aggressive media. With IFC 300 or IFC 400 converters it supports 4-20 mA, HART, FF, Profibus PA and Modbus.

This page is a selection overview. The figures shown are published range values; refer to the official datasheet; verify with the manufacturer.

Above: product appearance / manufacturer literature image.

2. Technical Description

Measuring principle: Faraday electromagnetic induction for conductive liquids.

Nominal bore: DN2.5 to DN3000 family; this model DN25 to DN1000.

Liner options: PTFE or PFA for chemical media.

Process temperature: Up to +180 deg C.

Process pressure: Up to PN40 / Class 300.

Outputs: 4-20 mA / HART / FF / Profibus PA / Modbus with IFC 300 or IFC 400.

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX product page https://www.krohne.com/en/products/electromagnetic-flowmeters/optiflux/

3. Main Technical Specifications

ParameterSpecification / Description
Product typeFull-bore electromagnetic flowmeter, chemical / power duty
Series / modelKROHNE POWERFLUX 4030
Measuring principleFaraday law of electromagnetic induction
Nominal boreDN25 to DN1000 (family DN2.5 to DN3000)
LinerPTFE or PFA
Conductivity>= 1 uS/cm
Process temperatureUp to +180 deg C
Process pressureUp to PN40 / Class 300
Outputs4-20 mA, HART, FF, Profibus PA, Modbus
Signal converterIFC 300 or IFC 400, ordered separately
Version optionsC compact / W wall remote / F field remote / R panel
ApplicationHigh-temperature and corrosive industrial media
Accuracy and orderingrefer to the official datasheet; verify with the manufacturer; Ordering code per the official datasheet; verify with the manufacturer
Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX product page https://www.krohne.com/en/products/electromagnetic-flowmeters/optiflux/

4. Selection Guide

Selection sequence: Medium check -> Bore sizing -> Liner selection -> Operating limits -> Converter and bus -> Verification.

StepItemKey point
1Medium checkConfirm a conductive chemical medium with conductivity >= 1 uS/cm
2Bore sizingChoose DN25 to DN1000 to match the process line
3Liner selectionSelect PTFE or PFA for the medium and temperature
4Operating limitsVerify +180 deg C maximum temperature and PN40 / Class 300 pressure
5Converter and busChoose IFC 300 or IFC 400 and the 4-20 mA / HART / FF / Profibus PA / Modbus outputs
6VerificationConfirm the complete configuration against the official datasheet; Ordering code per the official datasheet; verify with the manufacturer

Boundary: Published figures are family limits. Exact wetted materials, ratings and ordering code are per the official datasheet; Ordering code per the official datasheet; verify with the manufacturer.

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX product page https://www.krohne.com/en/products/electromagnetic-flowmeters/optiflux/

5. Complete Model Enumeration

Model familyPositionDescription
OPTIFLUX 2000General-purpose full-boreFull-bore electromagnetic flowmeters for water, wastewater and general industrial duty
OPTIFLUX 4000Chemical and processPTFE / PFA lined meters for corrosive and higher-temperature industrial media
WATERFLUX 3000Water utility meterBattery-powered water meters with no straight-run requirement and bidirectional measurement
TIDALFLUX 2300Partially filled pipeElectromagnetic flowmeter with integral level measurement for gravity and combined sewers
AF-E 400Legacy seriesEarlier 4-20 mA transmitter / sensor combination for existing automation loops

6. Related Models

Related modelDescription
KROHNE OPTIFLUX 4050Chemical-service meter in the same 4000 platform
KROHNE OPTIFLUX 4100Stainless steel high-pressure chemical meter
KROHNE IFC 300Multiprotocol signal converter
KROHNE IFC 400Converter for SIL and multiphase applications

7. Common Spare Parts

Spare partDescription
Measuring electrodeMatched to the original bore and PTFE / PFA liner
PTFE or PFA linerSelected to the original nominal bore
IFC converter moduleReplacement matched to the original protocol set
Excitation coilReplacement matched to the sensor size
Grounding ring and gasketsMatched to the original flange rating

8. Accessories

AccessoryDescription
IFC 300 / IFC 400 converterSelected to the required protocol set
Profibus PA / FF segment couplerFor fieldbus integration
Grounding ringFor reliable earthing of the tube
Remote mounting kitFor wall or field converter separation
Flange adapterMatched to the plant piping class

9. Disclaimer

The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources & Contact

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX product page https://www.krohne.com/en/products/electromagnetic-flowmeters/optiflux/.

We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area