KROHNE POWERFLUX 4030 Electromagnetic Flowmeter DN25-1000 Full-Bore Design
1. Product Overview
The KROHNE POWERFLUX 4030 belongs to the OPTIFLUX 4000 platform and is the designation used for chemical and power industry applications. It is a full-bore electromagnetic flowmeter for higher-temperature and general industrial duties.
The family covers DN2.5 to DN3000, with this model specified DN25 to DN1000. PTFE or PFA liners, a conductivity requirement of >= 1 uS/cm, process temperature up to +180 deg C and pressure up to PN40 / Class 300 make it suitable for aggressive media. With IFC 300 or IFC 400 converters it supports 4-20 mA, HART, FF, Profibus PA and Modbus.
This page is a selection overview. The figures shown are published range values; refer to the official datasheet; verify with the manufacturer.



2. Technical Description
Measuring principle: Faraday electromagnetic induction for conductive liquids.
Nominal bore: DN2.5 to DN3000 family; this model DN25 to DN1000.
Liner options: PTFE or PFA for chemical media.
Process temperature: Up to +180 deg C.
Process pressure: Up to PN40 / Class 300.
Outputs: 4-20 mA / HART / FF / Profibus PA / Modbus with IFC 300 or IFC 400.
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Product type | Full-bore electromagnetic flowmeter, chemical / power duty |
| Series / model | KROHNE POWERFLUX 4030 |
| Measuring principle | Faraday law of electromagnetic induction |
| Nominal bore | DN25 to DN1000 (family DN2.5 to DN3000) |
| Liner | PTFE or PFA |
| Conductivity | >= 1 uS/cm |
| Process temperature | Up to +180 deg C |
| Process pressure | Up to PN40 / Class 300 |
| Outputs | 4-20 mA, HART, FF, Profibus PA, Modbus |
| Signal converter | IFC 300 or IFC 400, ordered separately |
| Version options | C compact / W wall remote / F field remote / R panel |
| Application | High-temperature and corrosive industrial media |
| Accuracy and ordering | refer to the official datasheet; verify with the manufacturer; Ordering code per the official datasheet; verify with the manufacturer |
4. Selection Guide
Selection sequence: Medium check -> Bore sizing -> Liner selection -> Operating limits -> Converter and bus -> Verification.
| Step | Item | Key point |
|---|---|---|
| 1 | Medium check | Confirm a conductive chemical medium with conductivity >= 1 uS/cm |
| 2 | Bore sizing | Choose DN25 to DN1000 to match the process line |
| 3 | Liner selection | Select PTFE or PFA for the medium and temperature |
| 4 | Operating limits | Verify +180 deg C maximum temperature and PN40 / Class 300 pressure |
| 5 | Converter and bus | Choose IFC 300 or IFC 400 and the 4-20 mA / HART / FF / Profibus PA / Modbus outputs |
| 6 | Verification | Confirm the complete configuration against the official datasheet; Ordering code per the official datasheet; verify with the manufacturer |
Boundary: Published figures are family limits. Exact wetted materials, ratings and ordering code are per the official datasheet; Ordering code per the official datasheet; verify with the manufacturer.
5. Complete Model Enumeration
| Model family | Position | Description |
|---|---|---|
| OPTIFLUX 2000 | General-purpose full-bore | Full-bore electromagnetic flowmeters for water, wastewater and general industrial duty |
| OPTIFLUX 4000 | Chemical and process | PTFE / PFA lined meters for corrosive and higher-temperature industrial media |
| WATERFLUX 3000 | Water utility meter | Battery-powered water meters with no straight-run requirement and bidirectional measurement |
| TIDALFLUX 2300 | Partially filled pipe | Electromagnetic flowmeter with integral level measurement for gravity and combined sewers |
| AF-E 400 | Legacy series | Earlier 4-20 mA transmitter / sensor combination for existing automation loops |
6. Related Models
| Related model | Description |
|---|---|
| KROHNE OPTIFLUX 4050 | Chemical-service meter in the same 4000 platform |
| KROHNE OPTIFLUX 4100 | Stainless steel high-pressure chemical meter |
| KROHNE IFC 300 | Multiprotocol signal converter |
| KROHNE IFC 400 | Converter for SIL and multiphase applications |
7. Common Spare Parts
| Spare part | Description |
|---|---|
| Measuring electrode | Matched to the original bore and PTFE / PFA liner |
| PTFE or PFA liner | Selected to the original nominal bore |
| IFC converter module | Replacement matched to the original protocol set |
| Excitation coil | Replacement matched to the sensor size |
| Grounding ring and gaskets | Matched to the original flange rating |
8. Accessories
| Accessory | Description |
|---|---|
| IFC 300 / IFC 400 converter | Selected to the required protocol set |
| Profibus PA / FF segment coupler | For fieldbus integration |
| Grounding ring | For reliable earthing of the tube |
| Remote mounting kit | For wall or field converter separation |
| Flange adapter | Matched to the plant piping class |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文
ENGLISH