Home » Products » KROHNE
KROHNE WATERFLUX 3070 Electromagnetic Flowmeter with Low Pressure Loss for Water
KROHNE WATERFLUX 3070 Electromagnetic Flowmeter with Low Pressure Loss for Water
KROHNE WATERFLUX 3070 Electromagnetic Flowmeter with Low Pressure Loss for Water

KROHNE WATERFLUX 3070 Electromagnetic Flowmeter with Low Pressure Loss for Water

Details

1. Product Overview

The KROHNE WATERFLUX 3070 is a low-pressure-loss electromagnetic water meter in the WATERFLUX 3000 series. Its flow tube is designed to minimise head loss while retaining the accuracy and reliability of electromagnetic measurement for water supply duties.

The meter is specified over DN50 to DN1600 with PN16 process pressure and a conductivity requirement of >= 5 uS/cm. It offers 4-20 mA, pulse and infrared outputs with optional NB-IoT, and like the rest of the series supports bidirectional measurement and empty-pipe detection.

This page is a selection overview. The figures shown are published range values; refer to the official datasheet; verify with the manufacturer.

Above: product appearance / manufacturer literature image.

2. Technical Description

Measuring principle: Electromagnetic induction for conductive water.

Nominal bore: DN50 to DN1600.

Flow tube: Low-pressure-loss design.

Process pressure: PN16; confirm the exact class with the manufacturer.

Outputs: 4-20 mA / pulse / infrared / optional NB-IoT.

Measurement: Bidirectional with empty-pipe detection.

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official WATERFLUX product page https://www.krohne.com/en/products/electromagnetic-flowmeters/waterflux-3000/

3. Main Technical Specifications

ParameterSpecification / Description
Product typeLow-pressure-loss electromagnetic water meter
Series / modelKROHNE WATERFLUX 3070
Measuring principleFaraday law of electromagnetic induction
Nominal boreDN50 to DN1600
Conductivity>= 5 uS/cm
Process pressurePN16, subject to confirmation
Process temperaturerefer to the official datasheet; verify with the manufacturer
Power supplyBattery operation per the official datasheet
Outputs4-20 mA, pulse, infrared; NB-IoT optional
Straight-run requirementNone
MeasurementBidirectional flow with empty-pipe detection
ApplicationWater supply and distribution with low head loss
Accuracy and orderingrefer to the official datasheet; verify with the manufacturer; Ordering code per the official datasheet; verify with the manufacturer
Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official WATERFLUX product page https://www.krohne.com/en/products/electromagnetic-flowmeters/waterflux-3000/

4. Selection Guide

Selection sequence: Duty definition -> Bore sizing -> Pressure class -> Power and siting -> Communication -> Verification.

StepItemKey point
1Duty definitionConfirm a water application where low pressure loss is important
2Bore sizingChoose DN50 to DN1600 to match the line and flow range
3Pressure classConfirm PN16 is adequate for the installation
4Power and sitingUse the battery version where no mains supply is available
5CommunicationSelect 4-20 mA, pulse, infrared or optional NB-IoT
6VerificationConfirm final pressure rating and ordering code with the official datasheet; Ordering code per the official datasheet; verify with the manufacturer

Boundary: The pressure class shown is a family value. Confirm the exact rating and configuration with the manufacturer; refer to the official datasheet; verify with the manufacturer.

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official WATERFLUX product page https://www.krohne.com/en/products/electromagnetic-flowmeters/waterflux-3000/

5. Complete Model Enumeration

Model familyPositionDescription
OPTIFLUX 2000General-purpose full-boreFull-bore electromagnetic flowmeters for water, wastewater and general industrial duty
OPTIFLUX 4000Chemical and processPTFE / PFA lined meters for corrosive and higher-temperature industrial media
WATERFLUX 3000Water utility meterBattery-powered water meters with no straight-run requirement and bidirectional measurement
TIDALFLUX 2300Partially filled pipeElectromagnetic flowmeter with integral level measurement for gravity and combined sewers
AF-E 400Legacy seriesEarlier 4-20 mA transmitter / sensor combination for existing automation loops

6. Related Models

Related modelDescription
KROHNE WATERFLUX 3050HART-equipped water meter with long battery life
KROHNE WATERFLUX 3100Large-bore low-pressure-loss water meter
KROHNE WATERFLUX 3300Wide-range low-pressure-loss water meter
KROHNE OPTIFLUX 2300Full-bore stainless steel water flowmeter

7. Common Spare Parts

Spare partDescription
Battery packReplacement matched to the original configuration
Measuring electrodeMatched to the original sensor bore
NB-IoT communication moduleReplacement for the original radio option
Display boardMatched to the original meter version
Flange gasket setMatched to the original PN16 flange

8. Accessories

AccessoryDescription
NB-IoT moduleFor remote reading over narrowband networks
Infrared readout headFor local data retrieval
Pulse output interfaceFor external totalisers
Battery service kitFor planned field replacement
Flange adapterMatched to the plant piping class

9. Disclaimer

The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources & Contact

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official WATERFLUX product page https://www.krohne.com/en/products/electromagnetic-flowmeters/waterflux-3000/.

We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area