KROHNE TIDALFLUX 2300 Stainless Steel Electromagnetic Flowmeter DN200-1600 for P
1. Product Overview
The KROHNE TIDALFLUX 2300 is an electromagnetic flowmeter for partially filled pipes. It combines flow measurement with integral level measurement, making it suited to combined sewers, open channels and gravity-flow lines where the pipe is not running full.
The series covers DN200 to DN3000, with this model specified DN200 to DN1600, and is designed around PN10 process pressure. With 4-20 mA and HART outputs it can report flow together with the level signal to a control or telemetry system.
This page is a selection overview. The figures shown are published range values; refer to the official datasheet; verify with the manufacturer.



2. Technical Description
Measuring principle: Electromagnetic induction with integral level measurement.
Nominal bore: DN200 to DN3000 family; this model DN200 to DN1600.
Application: Partially filled pipes, combined sewers and gravity lines.
Process pressure: PN10 per the series.
Outputs: 4-20 mA / HART.
Note: For full-pipe duties use OPTIFLUX or WATERFLUX instead.
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Product type | Partially filled pipe electromagnetic flowmeter |
| Series / model | KROHNE TIDALFLUX 2300 |
| Measuring principle | Electromagnetic induction with level measurement |
| Nominal bore | DN200 to DN1600 (family DN200 to DN3000) |
| Body | Stainless steel, per the official product literature |
| Conductivity | >= 5 uS/cm |
| Process temperature | refer to the official datasheet; verify with the manufacturer |
| Process pressure | PN10 per the series |
| Outputs | 4-20 mA, HART |
| Level measurement | Integral, for partially filled operation |
| Version options | refer to the official datasheet; verify with the manufacturer |
| Application | Combined sewer, open channel and gravity-flow measurement |
| Accuracy and ordering | refer to the official datasheet; verify with the manufacturer; Ordering code per the official datasheet; verify with the manufacturer |
4. Selection Guide
Selection sequence: Pipe condition -> Bore sizing -> Level range -> Pressure check -> Outputs -> Verification.
| Step | Item | Key point |
|---|---|---|
| 1 | Pipe condition | Confirm the line runs partially filled or as gravity flow |
| 2 | Bore sizing | Choose DN200 to DN1600 within the DN200 to DN3000 family |
| 3 | Level range | Verify the integral level measurement covers the expected fill range |
| 4 | Pressure check | Confirm PN10 process pressure is adequate for the installation |
| 5 | Outputs | Select 4-20 mA and HART for flow and level transmission |
| 6 | Verification | For full-pipe duty use OPTIFLUX / WATERFLUX; otherwise confirm with the official datasheet; Ordering code per the official datasheet; verify with the manufacturer |
Boundary: Designed for non-full-pipe measurement. Where the pipe runs full, select OPTIFLUX or WATERFLUX; refer to the official datasheet; verify with the manufacturer.
5. Complete Model Enumeration
| Model family | Position | Description |
|---|---|---|
| OPTIFLUX 2000 | General-purpose full-bore | Full-bore electromagnetic flowmeters for water, wastewater and general industrial duty |
| OPTIFLUX 4000 | Chemical and process | PTFE / PFA lined meters for corrosive and higher-temperature industrial media |
| WATERFLUX 3000 | Water utility meter | Battery-powered water meters with no straight-run requirement and bidirectional measurement |
| TIDALFLUX 2300 | Partially filled pipe | Electromagnetic flowmeter with integral level measurement for gravity and combined sewers |
| AF-E 400 | Legacy series | Earlier 4-20 mA transmitter / sensor combination for existing automation loops |
6. Related Models
| Related model | Description |
|---|---|
| KROHNE OPTIFLUX 2050 | Full-bore meter for full-pipe water and wastewater |
| KROHNE OPTIFLUX 2300 | Stainless steel full-bore meter for water |
| KROHNE WATERFLUX 3000 | Full-bore battery-powered water meter |
| KROHNE IFC 300 | HART signal converter for process integration |
7. Common Spare Parts
| Spare part | Description |
|---|---|
| Measuring electrode | Matched to the original sensor bore |
| Level sensor | Replacement matched to the original measuring range |
| Signal converter module | IFC series unit with HART |
| Excitation coil | Replacement matched to the sensor size |
| Seal and gasket set | Matched to the original flange and body |
8. Accessories
| Accessory | Description |
|---|---|
| IFC signal converter | For 4-20 mA and HART integration |
| Grounding ring | For dependable earthing in the pipe |
| Level calibration kit | For field verification of the level channel |
| Remote mounting kit | Where the converter is installed away from the sensor |
| Flange adapter | Matched to the site piping class |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China