1. Product Overview

The KROHNE TIDALFLUX 2300 is an electromagnetic flowmeter for partially filled pipes. It combines flow measurement with integral level measurement, making it suited to combined sewers, open channels and gravity-flow lines where the pipe is not running full.

The series covers DN200 to DN3000, with this model specified DN200 to DN1600, and is designed around PN10 process pressure. With 4-20 mA and HART outputs it can report flow together with the level signal to a control or telemetry system.

This page is a selection overview. The figures shown are published range values; refer to the official datasheet; verify with the manufacturer.

Above: product appearance / manufacturer literature image.

2. Technical Description

Measuring principle: Electromagnetic induction with integral level measurement.

Nominal bore: DN200 to DN3000 family; this model DN200 to DN1600.

Application: Partially filled pipes, combined sewers and gravity lines.

Process pressure: PN10 per the series.

Outputs: 4-20 mA / HART.

Note: For full-pipe duties use OPTIFLUX or WATERFLUX instead.

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official TIDALFLUX product page https://www.krohne.com/en/products/electromagnetic-flowmeters/tidalflux-2300/

3. Main Technical Specifications

ParameterSpecification / Description
Product typePartially filled pipe electromagnetic flowmeter
Series / modelKROHNE TIDALFLUX 2300
Measuring principleElectromagnetic induction with level measurement
Nominal boreDN200 to DN1600 (family DN200 to DN3000)
BodyStainless steel, per the official product literature
Conductivity>= 5 uS/cm
Process temperaturerefer to the official datasheet; verify with the manufacturer
Process pressurePN10 per the series
Outputs4-20 mA, HART
Level measurementIntegral, for partially filled operation
Version optionsrefer to the official datasheet; verify with the manufacturer
ApplicationCombined sewer, open channel and gravity-flow measurement
Accuracy and orderingrefer to the official datasheet; verify with the manufacturer; Ordering code per the official datasheet; verify with the manufacturer
Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official TIDALFLUX product page https://www.krohne.com/en/products/electromagnetic-flowmeters/tidalflux-2300/

4. Selection Guide

Selection sequence: Pipe condition -> Bore sizing -> Level range -> Pressure check -> Outputs -> Verification.

StepItemKey point
1Pipe conditionConfirm the line runs partially filled or as gravity flow
2Bore sizingChoose DN200 to DN1600 within the DN200 to DN3000 family
3Level rangeVerify the integral level measurement covers the expected fill range
4Pressure checkConfirm PN10 process pressure is adequate for the installation
5OutputsSelect 4-20 mA and HART for flow and level transmission
6VerificationFor full-pipe duty use OPTIFLUX / WATERFLUX; otherwise confirm with the official datasheet; Ordering code per the official datasheet; verify with the manufacturer

Boundary: Designed for non-full-pipe measurement. Where the pipe runs full, select OPTIFLUX or WATERFLUX; refer to the official datasheet; verify with the manufacturer.

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official TIDALFLUX product page https://www.krohne.com/en/products/electromagnetic-flowmeters/tidalflux-2300/

5. Complete Model Enumeration

Model familyPositionDescription
OPTIFLUX 2000General-purpose full-boreFull-bore electromagnetic flowmeters for water, wastewater and general industrial duty
OPTIFLUX 4000Chemical and processPTFE / PFA lined meters for corrosive and higher-temperature industrial media
WATERFLUX 3000Water utility meterBattery-powered water meters with no straight-run requirement and bidirectional measurement
TIDALFLUX 2300Partially filled pipeElectromagnetic flowmeter with integral level measurement for gravity and combined sewers
AF-E 400Legacy seriesEarlier 4-20 mA transmitter / sensor combination for existing automation loops

6. Related Models

Related modelDescription
KROHNE OPTIFLUX 2050Full-bore meter for full-pipe water and wastewater
KROHNE OPTIFLUX 2300Stainless steel full-bore meter for water
KROHNE WATERFLUX 3000Full-bore battery-powered water meter
KROHNE IFC 300HART signal converter for process integration

7. Common Spare Parts

Spare partDescription
Measuring electrodeMatched to the original sensor bore
Level sensorReplacement matched to the original measuring range
Signal converter moduleIFC series unit with HART
Excitation coilReplacement matched to the sensor size
Seal and gasket setMatched to the original flange and body

8. Accessories

AccessoryDescription
IFC signal converterFor 4-20 mA and HART integration
Grounding ringFor dependable earthing in the pipe
Level calibration kitFor field verification of the level channel
Remote mounting kitWhere the converter is installed away from the sensor
Flange adapterMatched to the site piping class

9. Disclaimer

The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources & Contact

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official TIDALFLUX product page https://www.krohne.com/en/products/electromagnetic-flowmeters/tidalflux-2300/.

We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area