Home » Products » KROHNE
KROHNE OPTIFLUX 2300 Stainless Steel Electromagnetic Flowmeter DN25-3000 for Wat
KROHNE OPTIFLUX 2300 Stainless Steel Electromagnetic Flowmeter DN25-3000 for Wat
KROHNE OPTIFLUX 2300 Stainless Steel Electromagnetic Flowmeter DN25-3000 for Wat

KROHNE OPTIFLUX 2300 Stainless Steel Electromagnetic Flowmeter DN25-3000 for Wat

Details

1. Product Overview

The KROHNE OPTIFLUX 2300 is a stainless steel full-bore electromagnetic flowmeter from the OPTIFLUX 2000 platform and is a main model for water applications. It measures on the Faraday induction principle and is built for raw water, potable water distribution and circulating water duties.

The meter covers DN25 to DN3000 and offers rubber or PFA liners, with 4-20 mA, HART, pulse and frequency outputs through the IFC signal converter. For very large bores above DN1000 the liner and transport segmentation should be checked against the official datasheet before ordering.

This page is a selection overview. The figures shown are published range values; refer to the official datasheet; verify with the manufacturer.

Above: product appearance / manufacturer literature image.

2. Technical Description

Measuring principle: Faraday electromagnetic induction for conductive liquids.

Nominal bore: DN25 to DN3000.

Body: Stainless steel for water applications.

Liner options: Rubber or PFA.

Process temperature: Up to +130 deg C, depending on the liner.

Process pressure: PN10 to PN40.

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX product page https://www.krohne.com/en/products/electromagnetic-flowmeters/optiflux/

3. Main Technical Specifications

ParameterSpecification / Description
Product typeFull-bore electromagnetic flowmeter, stainless steel
Series / modelKROHNE OPTIFLUX 2300
Measuring principleFaraday law of electromagnetic induction
Nominal boreDN25 to DN3000
LinerRubber or PFA
Conductivity>= 5 uS/cm
Process temperatureUp to +130 deg C, depending on liner
Process pressurePN10 to PN40
Outputs4-20 mA, HART, pulse, frequency
Signal converterIFC series, ordered separately
Version optionsC compact / W wall remote / F field remote / R panel
ApplicationRaw water, potable water and circulating water
Accuracy and orderingrefer to the official datasheet; verify with the manufacturer; Ordering code per the official datasheet; verify with the manufacturer
Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX product page https://www.krohne.com/en/products/electromagnetic-flowmeters/optiflux/

4. Selection Guide

Selection sequence: Medium check -> Bore sizing -> Large-bore check -> Operating limits -> Converter and outputs -> Verification.

StepItemKey point
1Medium checkConfirm water or a conductive liquid with conductivity >= 5 uS/cm
2Bore sizingChoose DN25 to DN3000 to match the pipeline
3Large-bore checkFor bores above DN1000 verify the liner and transport segmentation
4Operating limitsCheck +130 deg C maximum temperature and PN10 to PN40 pressure
5Converter and outputsSelect the IFC converter and 4-20 mA / HART / pulse / frequency outputs
6VerificationConfirm the complete configuration against the official datasheet; Ordering code per the official datasheet; verify with the manufacturer

Boundary: Published figures are family limits. Large-bore construction and the ordering code are per the official datasheet; Ordering code per the official datasheet; verify with the manufacturer.

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX product page https://www.krohne.com/en/products/electromagnetic-flowmeters/optiflux/

5. Complete Model Enumeration

Model familyPositionDescription
OPTIFLUX 2000General-purpose full-boreFull-bore electromagnetic flowmeters for water, wastewater and general industrial duty
OPTIFLUX 4000Chemical and processPTFE / PFA lined meters for corrosive and higher-temperature industrial media
WATERFLUX 3000Water utility meterBattery-powered water meters with no straight-run requirement and bidirectional measurement
TIDALFLUX 2300Partially filled pipeElectromagnetic flowmeter with integral level measurement for gravity and combined sewers
AF-E 400Legacy seriesEarlier 4-20 mA transmitter / sensor combination for existing automation loops

6. Related Models

Related modelDescription
KROHNE OPTIFLUX 2050General-purpose full-bore electromagnetic flowmeter
KROHNE OPTIFLUX 2100Corrosion-resistant meter with HART communication
KROHNE WATERFLUX 3000Battery-powered water meter with no straight-run requirement
KROHNE IFC 300Multiprotocol signal converter

7. Common Spare Parts

Spare partDescription
Measuring electrodeMatched to the original sensor bore and liner
Rubber or PFA linerSelected to the original nominal bore
IFC converter moduleReplacement with matching outputs
Excitation coilReplacement matched to the sensor size
Grounding ring and gasketsMatched to the original flange

8. Accessories

AccessoryDescription
IFC signal converterCompact, wall, field or panel version as required
Grounding ringFor dependable earthing of the tube
Flange adapterMatched to the plant piping class
Remote mounting kitFor wall or field mounted converters
Large-bore transport supportsFor segmented delivery at very large nominal bores

9. Disclaimer

The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources & Contact

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX product page https://www.krohne.com/en/products/electromagnetic-flowmeters/optiflux/.

We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area