KROHNE OPTIFLUX 2300 Stainless Steel Electromagnetic Flowmeter DN25-3000 for Wat
1. Product Overview
The KROHNE OPTIFLUX 2300 is a stainless steel full-bore electromagnetic flowmeter from the OPTIFLUX 2000 platform and is a main model for water applications. It measures on the Faraday induction principle and is built for raw water, potable water distribution and circulating water duties.
The meter covers DN25 to DN3000 and offers rubber or PFA liners, with 4-20 mA, HART, pulse and frequency outputs through the IFC signal converter. For very large bores above DN1000 the liner and transport segmentation should be checked against the official datasheet before ordering.
This page is a selection overview. The figures shown are published range values; refer to the official datasheet; verify with the manufacturer.



2. Technical Description
Measuring principle: Faraday electromagnetic induction for conductive liquids.
Nominal bore: DN25 to DN3000.
Body: Stainless steel for water applications.
Liner options: Rubber or PFA.
Process temperature: Up to +130 deg C, depending on the liner.
Process pressure: PN10 to PN40.
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Product type | Full-bore electromagnetic flowmeter, stainless steel |
| Series / model | KROHNE OPTIFLUX 2300 |
| Measuring principle | Faraday law of electromagnetic induction |
| Nominal bore | DN25 to DN3000 |
| Liner | Rubber or PFA |
| Conductivity | >= 5 uS/cm |
| Process temperature | Up to +130 deg C, depending on liner |
| Process pressure | PN10 to PN40 |
| Outputs | 4-20 mA, HART, pulse, frequency |
| Signal converter | IFC series, ordered separately |
| Version options | C compact / W wall remote / F field remote / R panel |
| Application | Raw water, potable water and circulating water |
| Accuracy and ordering | refer to the official datasheet; verify with the manufacturer; Ordering code per the official datasheet; verify with the manufacturer |
4. Selection Guide
Selection sequence: Medium check -> Bore sizing -> Large-bore check -> Operating limits -> Converter and outputs -> Verification.
| Step | Item | Key point |
|---|---|---|
| 1 | Medium check | Confirm water or a conductive liquid with conductivity >= 5 uS/cm |
| 2 | Bore sizing | Choose DN25 to DN3000 to match the pipeline |
| 3 | Large-bore check | For bores above DN1000 verify the liner and transport segmentation |
| 4 | Operating limits | Check +130 deg C maximum temperature and PN10 to PN40 pressure |
| 5 | Converter and outputs | Select the IFC converter and 4-20 mA / HART / pulse / frequency outputs |
| 6 | Verification | Confirm the complete configuration against the official datasheet; Ordering code per the official datasheet; verify with the manufacturer |
Boundary: Published figures are family limits. Large-bore construction and the ordering code are per the official datasheet; Ordering code per the official datasheet; verify with the manufacturer.
5. Complete Model Enumeration
| Model family | Position | Description |
|---|---|---|
| OPTIFLUX 2000 | General-purpose full-bore | Full-bore electromagnetic flowmeters for water, wastewater and general industrial duty |
| OPTIFLUX 4000 | Chemical and process | PTFE / PFA lined meters for corrosive and higher-temperature industrial media |
| WATERFLUX 3000 | Water utility meter | Battery-powered water meters with no straight-run requirement and bidirectional measurement |
| TIDALFLUX 2300 | Partially filled pipe | Electromagnetic flowmeter with integral level measurement for gravity and combined sewers |
| AF-E 400 | Legacy series | Earlier 4-20 mA transmitter / sensor combination for existing automation loops |
6. Related Models
| Related model | Description |
|---|---|
| KROHNE OPTIFLUX 2050 | General-purpose full-bore electromagnetic flowmeter |
| KROHNE OPTIFLUX 2100 | Corrosion-resistant meter with HART communication |
| KROHNE WATERFLUX 3000 | Battery-powered water meter with no straight-run requirement |
| KROHNE IFC 300 | Multiprotocol signal converter |
7. Common Spare Parts
| Spare part | Description |
|---|---|
| Measuring electrode | Matched to the original sensor bore and liner |
| Rubber or PFA liner | Selected to the original nominal bore |
| IFC converter module | Replacement with matching outputs |
| Excitation coil | Replacement matched to the sensor size |
| Grounding ring and gaskets | Matched to the original flange |
8. Accessories
| Accessory | Description |
|---|---|
| IFC signal converter | Compact, wall, field or panel version as required |
| Grounding ring | For dependable earthing of the tube |
| Flange adapter | Matched to the plant piping class |
| Remote mounting kit | For wall or field mounted converters |
| Large-bore transport supports | For segmented delivery at very large nominal bores |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文