KROHNE OPTIFLUX 2100 Electromagnetic Flowmeter DN25-1200 Corrosion Resistant wit
1. Product Overview
The KROHNE OPTIFLUX 2100 is a corrosion-resistant full-bore electromagnetic flowmeter in the OPTIFLUX 2000 platform. It is intended for general industrial duties where the medium is aggressive and where HART communication is required for remote indication and diagnostics.
The meter covers DN25 to DN1200 with rubber or PFA liners and is used with the KROHNE IFC 100 or IFC 300 signal converter. Its 4-20 mA output with HART protocol integrates into conventional analogue loops while retaining digital communication, and the full-bore tube keeps pressure loss low.
This page is a selection overview. The figures shown are published range values; refer to the official datasheet; verify with the manufacturer.



2. Technical Description
Measuring principle: Faraday electromagnetic induction for conductive liquids.
Nominal bore: DN25 to DN1200.
Liner options: Rubber or PFA for corrosive media.
Process temperature: Up to +130 deg C, depending on the liner.
Process pressure: PN10 to PN40.
Outputs: 4-20 mA with HART, via IFC 100 or IFC 300 converter.
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Product type | Full-bore electromagnetic flowmeter |
| Series / model | KROHNE OPTIFLUX 2100 |
| Measuring principle | Faraday law of electromagnetic induction |
| Nominal bore | DN25 to DN1200 |
| Liner | Rubber or PFA |
| Conductivity | >= 5 uS/cm |
| Process temperature | Up to +130 deg C, depending on liner |
| Process pressure | PN10 to PN40 |
| Outputs | 4-20 mA with HART |
| Signal converter | IFC 100 or IFC 300, ordered separately |
| Version options | C compact / W wall remote / F field remote / R panel |
| Application | Corrosive general industrial flow with HART communication |
| Accuracy and ordering | refer to the official datasheet; verify with the manufacturer; Ordering code per the official datasheet; verify with the manufacturer |
4. Selection Guide
Selection sequence: Medium check -> Bore sizing -> Liner selection -> Operating limits -> Converter and protocol -> Verification.
| Step | Item | Key point |
|---|---|---|
| 1 | Medium check | Confirm the corrosive medium and conductivity >= 5 uS/cm |
| 2 | Bore sizing | Choose DN25 to DN1200 for the process line |
| 3 | Liner selection | Select PFA for aggressive media, rubber for non-aggressive duties |
| 4 | Operating limits | Verify +130 deg C maximum temperature and PN10 to PN40 pressure |
| 5 | Converter and protocol | Choose IFC 100 or IFC 300 with 4-20 mA and HART |
| 6 | Verification | Confirm the complete configuration against the official datasheet; Ordering code per the official datasheet; verify with the manufacturer |
Boundary: Published figures are family limits. Final wetted materials, ratings and ordering code are per the official datasheet; Ordering code per the official datasheet; verify with the manufacturer.
5. Complete Model Enumeration
| Model family | Position | Description |
|---|---|---|
| OPTIFLUX 2000 | General-purpose full-bore | Full-bore electromagnetic flowmeters for water, wastewater and general industrial duty |
| OPTIFLUX 4000 | Chemical and process | PTFE / PFA lined meters for corrosive and higher-temperature industrial media |
| WATERFLUX 3000 | Water utility meter | Battery-powered water meters with no straight-run requirement and bidirectional measurement |
| TIDALFLUX 2300 | Partially filled pipe | Electromagnetic flowmeter with integral level measurement for gravity and combined sewers |
| AF-E 400 | Legacy series | Earlier 4-20 mA transmitter / sensor combination for existing automation loops |
6. Related Models
| Related model | Description |
|---|---|
| KROHNE OPTIFLUX 2050 | General-purpose full-bore electromagnetic flowmeter |
| KROHNE OPTIFLUX 2300 | Stainless steel full-bore meter for water duty |
| KROHNE IFC 100 | Compact HART signal converter |
| KROHNE IFC 300 | Multiprotocol converter with HART, FF and Profibus PA |
| KROHNE POWERFLUX 4030 | Higher-temperature industrial electromagnetic flowmeter |
7. Common Spare Parts
| Spare part | Description |
|---|---|
| Measuring electrode | Matched to the original sensor bore and liner |
| PFA or rubber liner | Selected to the original nominal bore |
| IFC converter module | Replacement module with matching HART configuration |
| Excitation coil | Replacement matched to the sensor size |
| Flange gasket set | Matched to the original flange rating |
8. Accessories
| Accessory | Description |
|---|---|
| IFC 100 / IFC 300 converter | Selected to the required protocol set |
| HART communicator | For configuration and diagnostics of the loop |
| Grounding ring | For reliable earthing of the measuring tube |
| Remote mounting kit | For wall or field separation of the converter |
| Flange adapter | To match the plant piping class |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文
ENGLISH