Home » Products » KROHNE
KROHNE OPTIFLUX 2100 Electromagnetic Flowmeter DN25-1200 Corrosion Resistant wit
KROHNE OPTIFLUX 2100 Electromagnetic Flowmeter DN25-1200 Corrosion Resistant wit
KROHNE OPTIFLUX 2100 Electromagnetic Flowmeter DN25-1200 Corrosion Resistant wit

KROHNE OPTIFLUX 2100 Electromagnetic Flowmeter DN25-1200 Corrosion Resistant wit

Details

1. Product Overview

The KROHNE OPTIFLUX 2100 is a corrosion-resistant full-bore electromagnetic flowmeter in the OPTIFLUX 2000 platform. It is intended for general industrial duties where the medium is aggressive and where HART communication is required for remote indication and diagnostics.

The meter covers DN25 to DN1200 with rubber or PFA liners and is used with the KROHNE IFC 100 or IFC 300 signal converter. Its 4-20 mA output with HART protocol integrates into conventional analogue loops while retaining digital communication, and the full-bore tube keeps pressure loss low.

This page is a selection overview. The figures shown are published range values; refer to the official datasheet; verify with the manufacturer.

Above: product appearance / manufacturer literature image.

2. Technical Description

Measuring principle: Faraday electromagnetic induction for conductive liquids.

Nominal bore: DN25 to DN1200.

Liner options: Rubber or PFA for corrosive media.

Process temperature: Up to +130 deg C, depending on the liner.

Process pressure: PN10 to PN40.

Outputs: 4-20 mA with HART, via IFC 100 or IFC 300 converter.

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX product page https://www.krohne.com/en/products/electromagnetic-flowmeters/optiflux/

3. Main Technical Specifications

ParameterSpecification / Description
Product typeFull-bore electromagnetic flowmeter
Series / modelKROHNE OPTIFLUX 2100
Measuring principleFaraday law of electromagnetic induction
Nominal boreDN25 to DN1200
LinerRubber or PFA
Conductivity>= 5 uS/cm
Process temperatureUp to +130 deg C, depending on liner
Process pressurePN10 to PN40
Outputs4-20 mA with HART
Signal converterIFC 100 or IFC 300, ordered separately
Version optionsC compact / W wall remote / F field remote / R panel
ApplicationCorrosive general industrial flow with HART communication
Accuracy and orderingrefer to the official datasheet; verify with the manufacturer; Ordering code per the official datasheet; verify with the manufacturer
Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX product page https://www.krohne.com/en/products/electromagnetic-flowmeters/optiflux/

4. Selection Guide

Selection sequence: Medium check -> Bore sizing -> Liner selection -> Operating limits -> Converter and protocol -> Verification.

StepItemKey point
1Medium checkConfirm the corrosive medium and conductivity >= 5 uS/cm
2Bore sizingChoose DN25 to DN1200 for the process line
3Liner selectionSelect PFA for aggressive media, rubber for non-aggressive duties
4Operating limitsVerify +130 deg C maximum temperature and PN10 to PN40 pressure
5Converter and protocolChoose IFC 100 or IFC 300 with 4-20 mA and HART
6VerificationConfirm the complete configuration against the official datasheet; Ordering code per the official datasheet; verify with the manufacturer

Boundary: Published figures are family limits. Final wetted materials, ratings and ordering code are per the official datasheet; Ordering code per the official datasheet; verify with the manufacturer.

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX product page https://www.krohne.com/en/products/electromagnetic-flowmeters/optiflux/

5. Complete Model Enumeration

Model familyPositionDescription
OPTIFLUX 2000General-purpose full-boreFull-bore electromagnetic flowmeters for water, wastewater and general industrial duty
OPTIFLUX 4000Chemical and processPTFE / PFA lined meters for corrosive and higher-temperature industrial media
WATERFLUX 3000Water utility meterBattery-powered water meters with no straight-run requirement and bidirectional measurement
TIDALFLUX 2300Partially filled pipeElectromagnetic flowmeter with integral level measurement for gravity and combined sewers
AF-E 400Legacy seriesEarlier 4-20 mA transmitter / sensor combination for existing automation loops

6. Related Models

Related modelDescription
KROHNE OPTIFLUX 2050General-purpose full-bore electromagnetic flowmeter
KROHNE OPTIFLUX 2300Stainless steel full-bore meter for water duty
KROHNE IFC 100Compact HART signal converter
KROHNE IFC 300Multiprotocol converter with HART, FF and Profibus PA
KROHNE POWERFLUX 4030Higher-temperature industrial electromagnetic flowmeter

7. Common Spare Parts

Spare partDescription
Measuring electrodeMatched to the original sensor bore and liner
PFA or rubber linerSelected to the original nominal bore
IFC converter moduleReplacement module with matching HART configuration
Excitation coilReplacement matched to the sensor size
Flange gasket setMatched to the original flange rating

8. Accessories

AccessoryDescription
IFC 100 / IFC 300 converterSelected to the required protocol set
HART communicatorFor configuration and diagnostics of the loop
Grounding ringFor reliable earthing of the measuring tube
Remote mounting kitFor wall or field separation of the converter
Flange adapterTo match the plant piping class

9. Disclaimer

The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources & Contact

Source: KROHNE official product pages (krohne.com, krohnechina.com) and official brochures; official OPTIFLUX product page https://www.krohne.com/en/products/electromagnetic-flowmeters/optiflux/.

We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area