KROHNE OPTIFLUX 2050 Full-Bore Electromagnetic Flowmeter DN25-1200 for Water and
1. Product Overview
The KROHNE OPTIFLUX 2050 is a full-bore electromagnetic flowmeter from the OPTIFLUX 2000 platform, developed for general water, wastewater and industrial flow measurement. It operates on Faraday's law of electromagnetic induction and has no moving parts in the measuring tube, giving low pressure loss and stable long-term performance.
The meter is offered over a wide nominal bore range and can be fitted with rubber or PFA liners. Combined with the KROHNE IFC series signal converter, it provides 4-20 mA, HART, pulse and frequency outputs for process control and telemetry. The full-bore design makes it a common choice for large-diameter water and wastewater duties.
This page is a selection overview. The figures shown are published range values; refer to the official datasheet; verify with the manufacturer.



2. Technical Description
Measuring principle: Faraday electromagnetic induction, for conductive liquids and slurries.
Nominal bore: DN25 to DN3000 family; this model is specified DN25 to DN1200.
Liner options: Rubber or PFA, selected to suit the medium.
Process temperature: Up to +130 deg C, depending on the liner.
Process pressure: PN10 to PN40.
Outputs: 4-20 mA / HART / pulse / frequency with the IFC signal converter.
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Product type | Full-bore electromagnetic flowmeter |
| Series / model | KROHNE OPTIFLUX 2050 |
| Measuring principle | Faraday law of electromagnetic induction |
| Nominal bore | DN25 to DN1200 (family DN25 to DN3000) |
| Liner | Rubber or PFA |
| Conductivity | >= 5 uS/cm |
| Process temperature | Up to +130 deg C, depending on liner |
| Process pressure | PN10 to PN40 |
| Outputs | 4-20 mA, HART, pulse, frequency (with IFC converter) |
| Signal converter | IFC series, ordered separately |
| Version options | C compact / W wall remote / F field remote / R panel |
| Application | Water, wastewater and general industrial flow |
| Accuracy and ordering | refer to the official datasheet; verify with the manufacturer; Ordering code per the official datasheet; verify with the manufacturer |
4. Selection Guide
Selection sequence: Medium check -> Bore sizing -> Liner selection -> Operating limits -> Converter and outputs -> Verification.
| Step | Item | Key point |
|---|---|---|
| 1 | Medium check | Confirm a conductive liquid or slurry with conductivity >= 5 uS/cm |
| 2 | Bore sizing | Choose DN25 to DN1200 to match the line size and flow range |
| 3 | Liner selection | Use rubber for water and wastewater; use PFA for corrosive media |
| 4 | Operating limits | Check process temperature up to +130 deg C and pressure PN10 to PN40 |
| 5 | Converter and outputs | Select the IFC converter, 4-20 mA / HART / pulse / frequency and the mounting version |
| 6 | Verification | Confirm the complete flowmeter configuration against the official datasheet; Ordering code per the official datasheet; verify with the manufacturer |
Boundary: Full-bore range values are published limits. Final accuracy, pressure and temperature ratings and the ordering code are per the official datasheet; Ordering code per the official datasheet; verify with the manufacturer.
5. Complete Model Enumeration
| Model family | Position | Description |
|---|---|---|
| OPTIFLUX 2000 | General-purpose full-bore | Full-bore electromagnetic flowmeters for water, wastewater and general industrial duty |
| OPTIFLUX 4000 | Chemical and process | PTFE / PFA lined meters for corrosive and higher-temperature industrial media |
| WATERFLUX 3000 | Water utility meter | Battery-powered water meters with no straight-run requirement and bidirectional measurement |
| TIDALFLUX 2300 | Partially filled pipe | Electromagnetic flowmeter with integral level measurement for gravity and combined sewers |
| AF-E 400 | Legacy series | Earlier 4-20 mA transmitter / sensor combination for existing automation loops |
6. Related Models
| Related model | Description |
|---|---|
| KROHNE OPTIFLUX 2100 | Corrosion-resistant full-bore meter with HART communication |
| KROHNE OPTIFLUX 2300 | Stainless steel full-bore meter for water applications |
| KROHNE IFC 100 | Compact signal converter for OPTIFLUX sensors |
| KROHNE IFC 300 | Multiprotocol signal converter for advanced process duties |
| KROHNE WATERFLUX 3000 | Battery-powered water meter for utility networks |
7. Common Spare Parts
| Spare part | Description |
|---|---|
| Measuring electrode | Matched to the original sensor bore and liner material |
| Liner set | Rubber or PFA, matched to the original nominal bore |
| Signal converter module | IFC series replacement, matched to the original output configuration |
| Excitation coil | Replacement coil matched to the sensor size |
| Grounding ring and gaskets | Matched to the original flange and liner |
8. Accessories
| Accessory | Description |
|---|---|
| IFC signal converter | Compact, wall, field or panel version as required |
| Grounding ring | For reliable electrical contact with the medium |
| Flange adapter | Matched to the plant piping class |
| Remote mounting kit | For wall or field mounted converter separation |
| Sun and weather protection | For outdoor installation of the converter |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文
ENGLISH