Home » Products » KROHNE
KROHNE OPTIFLUX 1300 Wafer-style Electromagnetic Flowmeter for Chemical Service
KROHNE OPTIFLUX 1300 Wafer-style Electromagnetic Flowmeter for Chemical Service
KROHNE OPTIFLUX 1300 Wafer-style Electromagnetic Flowmeter for Chemical Service

KROHNE OPTIFLUX 1300 Wafer-style Electromagnetic Flowmeter for Chemical Service

Details

1. Product Overview

The Krohne OPTIFLUX 1300 is a chemical-resistant wafer electromagnetic flowmeter from the OPTIFLUX 1000 platform. It is used for small-bore measurement of corrosive chemical media where a compact wafer installation is preferred.

The sensor covers DN10 to DN150 with a PFA liner selected for chemical resistance. Minimum conductivity is 5 uS/cm, process temperature reaches up to +130 degC depending on liner, and pressure covers PN16 to PN40. Output options are 4-20 mA, HART and Modbus.

This page is a selection overview. Chemical compatibility, liner temperature limit and the complete ordering code are per the official data sheet; refer to the official datasheet; verify with the manufacturer.

Above: product appearance / manufacturer literature image.

2. Technical Description

Measuring principle: Faraday electromagnetic induction for conductive liquids.

Platform: OPTIFLUX 1000 economy wafer platform.

Nominal size: DN10 to DN150 in wafer execution.

Liner: PFA liner selected for chemical resistance.

Process conditions: Minimum conductivity 5 uS/cm; temperature up to +130 degC depending on liner; PN16 to PN40.

Output: 4-20 mA, HART and Modbus through the IFC converter.

Source: KROHNE official product pages (krohne.com) and KROHNE datasheets; official OPTIFLUX product page /en/products/electromagnetic-flowmeters/optiflux/

3. Main Technical Specifications

ParameterSpecification / Description
Product typeChemical-resistant wafer electromagnetic flowmeter
Series / modelKROHNE OPTIFLUX 1300
PlatformOPTIFLUX 1000 economy wafer platform
Nominal sizeDN10 to DN150, wafer
Measuring principleFaraday electromagnetic induction
LinerPFA for chemical resistance
Minimum conductivityat least 5 uS/cm
Process temperatureup to +130 degC depending on liner
Process pressurePN16 to PN40
Output / communication4-20 mA / HART / Modbus
Signal converterIFC series converter
Typical applicationCorrosive chemical media on small-bore wafer lines
Ordering codeOrdering code per official data sheet; verify with the manufacturer
Dimensions / weightSee the official data sheet for dimensions, mounting interface and weight
Source: KROHNE official product pages (krohne.com) and KROHNE datasheets; official OPTIFLUX product page /en/products/electromagnetic-flowmeters/optiflux/

4. Selection Guide

Selection sequence: Medium check -> Conductivity check -> Size check -> Process check -> Output check -> Ordering check.

StepItemKey point
1Medium checkConfirm chemical compatibility with the PFA liner and electrodes
2Conductivity checkConfirm liquid conductivity at or above 5 uS/cm
3Size checkConfirm a DN10 to DN150 wafer installation
4Process checkConfirm the liner temperature limit and PN16 to PN40 pressure
5Output checkChoose 4-20 mA, HART or Modbus with the IFC converter
6Ordering checkVerify the chemical configuration and complete code; Ordering code per official data sheet; verify with the manufacturer

Boundary: Chemical compatibility and the liner temperature limit are decisive for this platform. The official data sheet is the controlling document; Ordering code per official data sheet; verify with the manufacturer.

Source: KROHNE official product pages (krohne.com) and KROHNE datasheets; official OPTIFLUX product page /en/products/electromagnetic-flowmeters/optiflux/

5. Complete Model Enumeration

Model / configurationFunctionDescription
OPTIFLUX 1300 compactWafer flowmeterSensor with directly mounted IFC converter
OPTIFLUX 1300 remoteWafer flowmeterSensor with remote IFC converter
OPTIFLUX 1300 PFAChemical versionPFA liner for corrosive media
OPTIFLUX 1300 HARTCommunication option4-20 mA with HART
OPTIFLUX 1300 ModbusCommunication optionModbus with IFC converter
Other configurationsPer official data sheetOrdering code per official data sheet; verify with the manufacturer

6. Related Models

Related modelDescription
OPTIFLUX 1100Wafer flowmeter with HART as standard option
OPTIFLUX 1050Economy wafer flowmeter with optional HART
OPTIFLUX 1400Wafer flowmeter with multiphase option
OPTIFLUX 4400Chemical platform flowmeter for higher temperature
OPTIFLUX 5400Ceramic metering flowmeter for custody transfer

7. Common Spare Parts

Spare partDescription
PFA linerMatched to the original chemical service configuration
Measuring electrodesMatched to the original liner and nominal size
IFC converter moduleMatched to the original output option
Wafer gasket setSelected to the nominal size and liner
Grounding ringMatched to the original pipe and liner

8. Accessories

AccessoryDescription
IFC signal converterSelected for 4-20 mA, HART or Modbus
Chemical-resistant gasket setSelected to the process medium
Grounding ringFor reliable pipe bonding on lined lines
Remote mounting kitWhere the converter is mounted away from the sensor
Weather protectionFor outdoor installation where required

9. Disclaimer

The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.

10. Sources & Contact

Source: KROHNE official product pages (krohne.com) and KROHNE datasheets; official OPTIFLUX product page /en/products/electromagnetic-flowmeters/optiflux/.

We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com

Ordering & Inquiry

If you need help confirming model numbers, configurations or availability, please feel free to contact us. We can assist with selection and technical confirmation based on your operating conditions and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area