KROHNE OPTIFLUX 1300 Wafer-style Electromagnetic Flowmeter for Chemical Service
1. Product Overview
The Krohne OPTIFLUX 1300 is a chemical-resistant wafer electromagnetic flowmeter from the OPTIFLUX 1000 platform. It is used for small-bore measurement of corrosive chemical media where a compact wafer installation is preferred.
The sensor covers DN10 to DN150 with a PFA liner selected for chemical resistance. Minimum conductivity is 5 uS/cm, process temperature reaches up to +130 degC depending on liner, and pressure covers PN16 to PN40. Output options are 4-20 mA, HART and Modbus.
This page is a selection overview. Chemical compatibility, liner temperature limit and the complete ordering code are per the official data sheet; refer to the official datasheet; verify with the manufacturer.



2. Technical Description
Measuring principle: Faraday electromagnetic induction for conductive liquids.
Platform: OPTIFLUX 1000 economy wafer platform.
Nominal size: DN10 to DN150 in wafer execution.
Liner: PFA liner selected for chemical resistance.
Process conditions: Minimum conductivity 5 uS/cm; temperature up to +130 degC depending on liner; PN16 to PN40.
Output: 4-20 mA, HART and Modbus through the IFC converter.
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Product type | Chemical-resistant wafer electromagnetic flowmeter |
| Series / model | KROHNE OPTIFLUX 1300 |
| Platform | OPTIFLUX 1000 economy wafer platform |
| Nominal size | DN10 to DN150, wafer |
| Measuring principle | Faraday electromagnetic induction |
| Liner | PFA for chemical resistance |
| Minimum conductivity | at least 5 uS/cm |
| Process temperature | up to +130 degC depending on liner |
| Process pressure | PN16 to PN40 |
| Output / communication | 4-20 mA / HART / Modbus |
| Signal converter | IFC series converter |
| Typical application | Corrosive chemical media on small-bore wafer lines |
| Ordering code | Ordering code per official data sheet; verify with the manufacturer |
| Dimensions / weight | See the official data sheet for dimensions, mounting interface and weight |
4. Selection Guide
Selection sequence: Medium check -> Conductivity check -> Size check -> Process check -> Output check -> Ordering check.
| Step | Item | Key point |
|---|---|---|
| 1 | Medium check | Confirm chemical compatibility with the PFA liner and electrodes |
| 2 | Conductivity check | Confirm liquid conductivity at or above 5 uS/cm |
| 3 | Size check | Confirm a DN10 to DN150 wafer installation |
| 4 | Process check | Confirm the liner temperature limit and PN16 to PN40 pressure |
| 5 | Output check | Choose 4-20 mA, HART or Modbus with the IFC converter |
| 6 | Ordering check | Verify the chemical configuration and complete code; Ordering code per official data sheet; verify with the manufacturer |
Boundary: Chemical compatibility and the liner temperature limit are decisive for this platform. The official data sheet is the controlling document; Ordering code per official data sheet; verify with the manufacturer.
5. Complete Model Enumeration
| Model / configuration | Function | Description |
|---|---|---|
| OPTIFLUX 1300 compact | Wafer flowmeter | Sensor with directly mounted IFC converter |
| OPTIFLUX 1300 remote | Wafer flowmeter | Sensor with remote IFC converter |
| OPTIFLUX 1300 PFA | Chemical version | PFA liner for corrosive media |
| OPTIFLUX 1300 HART | Communication option | 4-20 mA with HART |
| OPTIFLUX 1300 Modbus | Communication option | Modbus with IFC converter |
| Other configurations | Per official data sheet | Ordering code per official data sheet; verify with the manufacturer |
6. Related Models
| Related model | Description |
|---|---|
| OPTIFLUX 1100 | Wafer flowmeter with HART as standard option |
| OPTIFLUX 1050 | Economy wafer flowmeter with optional HART |
| OPTIFLUX 1400 | Wafer flowmeter with multiphase option |
| OPTIFLUX 4400 | Chemical platform flowmeter for higher temperature |
| OPTIFLUX 5400 | Ceramic metering flowmeter for custody transfer |
7. Common Spare Parts
| Spare part | Description |
|---|---|
| PFA liner | Matched to the original chemical service configuration |
| Measuring electrodes | Matched to the original liner and nominal size |
| IFC converter module | Matched to the original output option |
| Wafer gasket set | Selected to the nominal size and liner |
| Grounding ring | Matched to the original pipe and liner |
8. Accessories
| Accessory | Description |
|---|---|
| IFC signal converter | Selected for 4-20 mA, HART or Modbus |
| Chemical-resistant gasket set | Selected to the process medium |
| Grounding ring | For reliable pipe bonding on lined lines |
| Remote mounting kit | Where the converter is mounted away from the sensor |
| Weather protection | For outdoor installation where required |
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult Tel: +86 028-60220547 / Email: info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China